250mm Galvanised Steel 90° Elbow - Round Ventilation Ducting Bend

Please sign in to see pricing

£8.47

The 250mm Galvanised Steel 90° Elbow is a rigid round ventilation bend designed to change the direction of 250mm ducting through approximately 90 degrees while maintaining the full nominal duct diameter.

Also known as a 250mm duct bend, ventilation elbow or 90-degree duct elbow, this fitting provides a purpose-made solution when a ventilation run needs to turn around walls, ceilings, equipment or other obstacles.

Its curved, segmented construction creates a controlled change of direction without requiring flexible ducting to be crushed or folded tightly around a corner. This helps maintain a more consistent airflow path while creating a stronger and neater ventilation installation.

Manufactured from galvanised steel, the elbow is suitable for 250mm extraction and intake systems used in grow rooms, commercial horticulture, workshops, warehouses and other medium to high-airflow ventilation applications.

Why choose a 250mm galvanised duct elbow?

  • 250mm nominal diameter - designed for compatible 250mm round ventilation systems.
  • 90-degree direction change - routes ventilation ducting around corners and obstacles.
  • Rigid curved construction - maintains a defined airflow passage through the bend.
  • Galvanised steel construction - strong and rigid for permanent and semi-permanent installations.
  • Same nominal diameter at both ends - maintains a 250mm duct size through the fitting.
  • Suitable for extraction and intake - suitable for exhaust-air and supply-air systems.
  • Useful in high-airflow systems - ideal where larger fans and ventilation components are installed.
  • Better than a crushed flexible bend - avoids forcing flexible ducting through an excessively tight corner.
  • Professional installation - creates a strong, tidy and purpose-made change of direction.

What is a 250mm ducting elbow used for?

A ventilation elbow allows a round duct run to change direction while retaining the same nominal diameter. This is useful wherever a straight duct route is not practical.

Typical applications include changing from horizontal to vertical ducting, routing an extraction system around a corner, directing ductwork towards an external outlet or positioning ducting correctly between fans, filters and silencers.

Because the fitting remains at a nominal 250mm diameter at both ends, it can be incorporated into a compatible 250mm system without intentionally reducing the duct size.

250mm duct elbow for grow room ventilation

Effective environmental control in an indoor growing area depends on moving sufficient air through the space. Extraction systems help remove heat and humidity while fresh-air intake contributes to regular air exchange.

Larger grow rooms frequently use 250mm ventilation equipment where substantial airflow is required. A rigid elbow allows the ductwork to change direction cleanly where the layout of the room prevents a straight run.

The fitting can be used as part of systems containing compatible 250mm inline fans, carbon filters, acoustic silencers and flexible or rigid ducting.

Avoid crushing flexible ducting around corners

Flexible ducting can negotiate gradual changes in direction, but forcing it through a very tight bend can compress the duct and reduce its effective internal area.

A rigid metal elbow provides a defined route through the corner, helping prevent the severe deformation that can occur when flexible duct is folded or crushed.

This can be particularly useful with larger 250mm ducting, where maintaining the shape of the ventilation route becomes increasingly important.

How does a 90° elbow affect airflow?

Any significant change in airflow direction introduces additional resistance into a ventilation system. A 90-degree elbow therefore creates more resistance than an equivalent straight section of duct.

The complete system should be considered when selecting a fan. Carbon filters, silencers, reducers, tee pieces, duct length and bends all contribute to the overall resistance the fan must overcome.

Keeping duct runs as short and direct as practical and avoiding unnecessary bends can help maintain airflow and improve the overall efficiency of the ventilation system.

Installing a 250mm ventilation elbow

Position the elbow at the required change of direction and ensure sufficient space is available for the fitting, adjoining ductwork and any clamps or supports.

Connect compatible 250mm ducting or ventilation components to each end. Flexible ducting can typically be secured using appropriately sized duct clamps or clips.

Where minimising air leakage is important, joints can additionally be sealed using suitable HVAC foil tape or another appropriate ventilation-system sealing method.

Support larger duct runs correctly so that unnecessary weight is not transferred to the elbow, fan, carbon filter or other connected equipment.

Building an efficient 250mm ventilation system

When designing a 250mm extraction or intake system, consider the complete airflow route rather than individual components in isolation.

A high-capacity fan connected to restrictive ductwork may deliver significantly less airflow than its unrestricted specification suggests. Keeping the correct duct diameter and reducing unnecessary bends, restrictions and excessively long runs can help preserve system performance.

Where a direction change is unavoidable, a purpose-made rigid elbow provides a controlled and repeatable way to route the ductwork around the obstacle.

Compatible 250mm ventilation equipment

The 250mm elbow can form part of a complete round ventilation system using appropriately sized components including:

  • 250mm flexible ventilation ducting
  • Compatible 250mm rigid round ducting
  • 250mm inline extraction fans
  • 250mm carbon filters
  • 250mm acoustic silencers
  • 250mm straight connectors
  • 250mm tee pieces
  • 250mm reducers and adapters
  • Suitable duct clamps, clips and sealing materials

Nominal duct diameter does not always confirm the exact male or female connection arrangement. Check the physical dimensions and fitting style of adjoining components before installation.

250mm Galvanised Steel Elbow product details

Product Round Ventilation Duct Elbow
Nominal diameter 250mm
Nominal bend angle 90°
Material Galvanised steel
Shape Round
Fitting type Ventilation elbow / duct bend
Number of connections 2
Nominal diameter change None - 250mm at both ends
Primary use Changing the direction of 250mm round ventilation ducting
Airflow application Extraction & intake ventilation systems
Suitable applications Grow rooms, commercial horticulture, workshops, warehouses & general ventilation installations

250mm Galvanised Steel Elbow FAQs

What is a 250mm duct elbow used for?

It allows compatible 250mm round ventilation ductwork to change direction while maintaining the same nominal duct diameter.

What angle is this ducting elbow?

It is a nominal 90-degree ventilation elbow designed for substantial changes in the direction of a duct run.

What is the elbow made from?

It is manufactured from galvanised steel, providing a rigid and durable fitting for ventilation installations.

Does this elbow reduce the duct size?

No. The fitting maintains a nominal 250mm diameter at both connections. A separate reducer is required if the system needs to transition to another duct size.

Can I connect 250mm flexible ducting to it?

Yes. Compatible 250mm flexible ducting can be connected and secured using appropriately sized duct clamps or clips.

Can it be used with rigid ducting?

Yes, provided the adjoining rigid ductwork has compatible dimensions and connection arrangements.

Can the elbow be used for extraction?

Yes. It is suitable for use in compatible 250mm extraction and exhaust-air ventilation systems.

Can it be used on an intake system?

Yes. The elbow can also be incorporated into compatible intake and supply-air ventilation systems.

Is a rigid elbow better than bending flexible duct?

A rigid elbow is particularly useful for tight direction changes because it avoids the severe crushing or deformation that can occur when flexible ducting is forced around a corner.

Does a 90-degree duct bend restrict airflow?

Any substantial direction change adds resistance to a ventilation system. The overall effect depends on the fan, duct layout and other components installed in the system.

Should I minimise the number of bends in my ducting?

Where practical, yes. Shorter, straighter duct routes generally create less resistance than systems containing numerous bends and other restrictions.

Should the elbow connections be sealed?

Where reducing air leakage is important, secure the joints correctly and seal them using suitable HVAC foil tape or another appropriate ventilation sealing method.

Can this be used with a 250mm carbon filter?

Yes. The elbow can form part of a ventilation system containing a compatible 250mm carbon filter, fan or acoustic silencer.

Is a 250mm elbow suitable for grow room ventilation?

Yes. It is suitable for medium and larger indoor horticultural ventilation systems where 250mm ductwork needs to change direction.

Does 250mm ductwork need supporting?

Yes. Larger duct runs should be properly supported so that excessive weight is not transferred to the elbow or adjoining fans, filters and other equipment.

Pay with

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • Shop Pay
  • Union Pay
  • Visa

Your transaction is protected with advanced security measures to keep your information confidential

£8.47