What is acoustic ducting?
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
36 products
36 products
Sort by:
£21.80
Unit price per£21.80
Unit price per254mm (10") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in powerful extraction and intake systems.
High-capacity ventilation equipment can generate significant noise from the fan itself and from fast-moving air travelling through the ductwork. This insulated ducting provides a practical solution where quieter ventilation is required without sacrificing the flexibility of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound transmitted along the ventilation system. It is particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a 5 metre length with a nominal 254mm / 10" diameter, it is suitable for compatible 10-inch fans, carbon filters and ventilation fittings and can be cut to the required length during installation.
Why choose 254mm acoustic silent ducting?
How does acoustic ducting reduce ventilation noise?
Noise from an extraction system does not only come directly from the fan. Fan noise, vibration and turbulent airflow can travel along ordinary ductwork, allowing sound to become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct run.
It can be particularly effective when used immediately before or after an extraction fan, between a fan and carbon filter, or along duct runs where ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make an extraction system completely silent. Fan type, speed, vibration, airflow velocity and installation quality will all influence the final sound level.
Ideal for 10-inch grow room ventilation systems
Larger grow rooms and indoor horticultural environments often require powerful ventilation to remove excess heat and humidity and maintain regular air exchange. As fan capacity increases, controlling ventilation noise becomes increasingly important.
The 254mm / 10" diameter makes this ducting suitable for compatible high-volume extraction and intake equipment, while its insulated construction helps reduce the sound transmitted through the ductwork.
It can be used as part of a complete ventilation system incorporating an inline fan, carbon filter, metal duct fittings, reducers and other appropriately sized components.
Getting the best airflow from flexible ducting
Good duct installation is important for maintaining the performance of an extraction fan. Every length of ducting, bend and fitting introduces some resistance to airflow.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This provides a smoother internal airflow path and helps reduce avoidable resistance.
Keep the ventilation route as short and direct as practical and avoid crushing the duct or creating unnecessarily tight bends. Gradual changes in direction are preferable to sharp turns.
The supplied 5m length does not need to be used in full. Cutting it to the length actually required can help create a cleaner and more efficient installation.
Installing 254mm Mute Silent Ducting
Before installation, check that the fan, carbon filter and other fittings are compatible with the nominal 254mm / 10" duct size.
Fit the flexible inner duct securely around the ventilation connection and fasten it using a suitably sized duct clamp or fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed connection so that the insulating layer remains as continuous as practical.
Longer sections should be supported appropriately along the route. Avoid allowing the full weight of the ducting to hang directly from an extraction fan, carbon filter or other ventilation component.
Compatible ventilation equipment
254mm acoustic ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of individual components before installation, as dimensions can vary slightly between different ventilation equipment manufacturers.
254mm (10") x 5m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
254mm (10") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system. What size is this ducting?
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 5 metre length. Is this suitable for a 10-inch extraction fan?
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Always check the fan connection dimensions before installation. Can I connect it to a 10-inch carbon filter?
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of a correctly sized extraction system. Does acoustic ducting make a fan silent?
No. It helps reduce noise transmitted through the ductwork but cannot completely eliminate fan motor noise, vibration or airflow noise. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting. Can it be used for both extraction and intake?
Yes. The ducting can be incorporated into compatible extraction or fresh-air intake systems. Can the 5m duct be cut into shorter sections?
Yes. It can be cut to suit the required installation, allowing one length to be divided into several sections if necessary. Should I use the entire 5m length?
Only if required. Keeping duct runs reasonably short and direct generally helps reduce resistance and maintain ventilation performance. Does long ducting reduce fan airflow?
Every duct run introduces resistance. Longer routes, tight bends and additional fittings can increase this resistance and reduce the effective airflow delivered by the system. Do bends in flexible ducting affect airflow?
Yes. Sharp bends increase resistance, so gradual changes in direction are preferable wherever the installation allows. Should acoustic ducting be stretched out?
It should be extended sufficiently for the installation rather than left heavily compressed, helping provide a smoother path for airflow. Where should acoustic ducting be positioned?
It can be used throughout a compatible ventilation route. Sections close to powerful extraction fans can be particularly useful for reducing sound transmitted into the duct system. Does 10-inch acoustic ducting need supporting?
Long runs should be adequately supported so the weight of the duct is not carried entirely by the fan, filter or connecting fittings. How else can I make a grow room extraction system quieter?
Good duct routing, correctly sized ventilation equipment, vibration isolation, suitable fan-speed control and ventilation silencers can all help reduce overall system noise.
£27.50
Unit price per£27.50
Unit price per203mm (8") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce the noise transmitted through extraction and intake systems.
Ventilation fans create more than just motor noise. Air movement, turbulence and vibration can all travel through standard ducting, making an otherwise effective extraction system noticeably louder. Acoustic ducting helps tackle this by surrounding the inner airflow path with an insulating layer that absorbs and reduces transmitted sound.
With a 203mm (8") internal duct diameter and 10m length, this ducting is particularly suited to medium and high-airflow ventilation systems used in grow rooms, indoor horticulture, workshops and other environments where reducing ventilation noise is important.
Its flexible construction also makes installation considerably easier than rigid ductwork where the ventilation route needs to negotiate equipment, corners or structural obstacles.
Why choose 203mm acoustic silent ducting?
How does acoustic ducting reduce noise?
A ventilation system can transmit sound along the same route used to move air. Fan noise and turbulence can travel through ordinary thin-walled ducting and emerge from the opposite end of the system.
Acoustic ducting is constructed differently. An inner flexible airflow duct is surrounded by sound-absorbing insulation and an outer protective layer. The insulation helps absorb some of the sound energy travelling through the duct rather than allowing it to transmit as readily along the ventilation run.
This makes insulated ducting particularly useful immediately before or after an extraction fan, between a fan and carbon filter, or along sections of ductwork where ventilation noise would otherwise be noticeable.
Reducing grow room extraction noise
For the quietest practical ventilation system, noise control should be considered throughout the complete installation rather than relying on one component alone.
Acoustic ducting can help reduce noise transmitted through the ductwork, while fan speed control, acoustic silencers, correctly sized ducting and vibration isolation can address other sources of sound.
Using adequately sized ducting is particularly important. Forcing a large volume of air through undersized ductwork increases air velocity and turbulence, which can make the ventilation system considerably noisier.
Ideal for grow rooms & indoor horticulture
Extraction is essential in many indoor growing environments, but larger fans can create significant noise when operating continuously.
203mm acoustic ducting provides a practical option for installations where 8-inch ventilation equipment is required but keeping the system quieter is also a priority.
It can be used with compatible extraction fans, carbon filters, silencers and other 203mm ventilation components to create a complete air-management system.
Installing 203mm silent ducting
Route the ducting as directly as practical between the ventilation components. Avoid unnecessary tight bends, excessive compression and long sections of heavily sagging duct, as these can increase resistance and turbulence.
When connecting the ducting to a fan, filter, silencer or metal fitting, secure the inner duct correctly to the connection and use a suitable duct clamp or clip. The outer insulated section can then be positioned neatly around the joint.
Where minimising air leakage is important, suitable HVAC foil tape can be used as part of the connection and sealing process.
Support longer duct runs at suitable intervals rather than allowing the weight of the ducting to hang directly from the fan, filter or other ventilation equipment.
Get the best airflow from flexible ducting
Flexible ducting works best when it is installed with unnecessary compression kept to a minimum. Extending the duct sufficiently helps reduce deep internal folds that can increase resistance to airflow.
Keep the route as short and straight as the installation allows. Every bend, restriction and additional length of duct contributes to the resistance the extraction fan must overcome.
Where a sharp 90-degree direction change is required, a compatible rigid metal elbow may provide a cleaner airflow route than forcing flexible ducting around an extremely tight corner.
Compatible 203mm / 8" ventilation equipment
The ducting is intended for compatible nominal 203mm (8") round ventilation systems and can be used alongside appropriately sized components such as:
Always check the actual connection diameter of adjoining equipment before installation, particularly where equipment is described using both metric and imperial sizes.
203mm (8") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 203mm / 8" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 203mm / 8" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, workshops & general ventilation installations |
203mm (8") Mute Silent Ducting FAQs
What is silent ducting?
Silent or acoustic ducting is flexible ventilation duct surrounded by an insulating layer designed to help absorb and reduce noise transmitted through the duct system. What size is this acoustic ducting?
It has a nominal internal duct diameter of 203mm, equivalent to approximately 8 inches, and is supplied in a 10m length. Will acoustic ducting make my extraction fan silent?
No. It is designed to reduce noise transmitted through the ductwork, but it cannot eliminate all fan, airflow or vibration noise. A quieter system may also require suitable fan control, vibration isolation and acoustic silencers. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce sound transmission through the duct compared with basic uninsulated flexible ventilation ducting. Can I use this with an 8-inch extraction fan?
Yes, provided the fan has a compatible nominal 203mm / 8" connection. Can I connect it to a carbon filter?
Yes. It can be used with a compatible 203mm / 8" carbon filter as part of an extraction system. Can silent ducting be used with an acoustic silencer?
Yes. Acoustic ducting and a compatible ventilation silencer can be used together as part of a system designed to reduce transmitted ventilation noise. Can I cut the 10m ducting to shorter lengths?
Yes. Flexible ducting can be cut to the length required for the installation using suitable tools, taking care to deal correctly with the internal reinforcement and insulation. Can this ducting be used for intake air?
Yes. It can be incorporated into compatible air-intake systems as well as extraction installations. Does acoustic ducting reduce airflow?
All ductwork creates some resistance. Flexible ducting should be installed without unnecessary compression, excessive length or tight bends to help minimise additional pressure loss. Should flexible ducting be fully stretched out?
It should generally be extended sufficiently to avoid excessive internal corrugation while using only the length needed for the installation. Unnecessary excess duct should not be left heavily compressed. Can I bend the ducting around corners?
Yes, its flexible construction allows direction changes. Avoid very tight bends that crush the internal duct, as these can increase airflow resistance and noise. How should I attach acoustic ducting to a fan?
Secure the inner duct to the compatible fan connection using a suitable duct clamp or clip, then arrange the insulation and outer covering neatly around the connection. Is 203mm acoustic ducting suitable for grow rooms?
Yes. It is particularly useful for indoor horticultural ventilation systems where 203mm extraction equipment is required and reducing fan and airflow noise is desirable. What else can I do to make a ventilation system quieter?
Use correctly sized ducting, minimise unnecessary bends, isolate fan vibration, avoid excessive air velocity and consider compatible fan-speed control and acoustic silencers where appropriate.
£12.92
Unit price per£12.92
Unit price per152mm (6") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce the transmission of fan and airflow noise through extraction and intake systems.
Ventilation systems can transmit a surprising amount of sound through standard ducting. Noise from the fan itself, together with turbulence and fast-moving air, can travel along the duct run and become audible at the inlet or outlet.
This acoustic ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical upgrade from standard uninsulated flexible ducting where quieter ventilation is required.
With a 152mm (6") nominal internal diameter and 5m length, it is particularly well suited to grow rooms, indoor horticulture, workshops and other ventilation installations using compatible 6-inch fans, carbon filters and duct fittings.
Why choose 152mm acoustic silent ducting?
How does acoustic ducting work?
Standard flexible ducting provides an airflow route but offers relatively little acoustic isolation. Sound generated by the extraction fan and moving air can therefore travel along the duct run.
Acoustic ducting adds a layer of sound-absorbing insulation around the inner flexible duct. This helps reduce the amount of sound transmitted through and along the ventilation run.
It is particularly useful on sections immediately before or after an extraction fan, between a carbon filter and fan, or wherever ventilation noise needs to be reduced.
Acoustic ducting should be considered a noise-reduction component rather than a complete silencing solution. Fan vibration, motor noise, airflow velocity and other parts of the installation can also contribute to the overall sound level.
Quieter 6-inch grow room ventilation
150mm and 152mm-class extraction systems are widely used where considerably more airflow is required than smaller ventilation systems can provide. As fan capacity increases, however, ventilation noise can become more noticeable.
Using acoustic ducting helps reduce sound transmitted along the ductwork while retaining the flexibility required to route the ventilation system around a grow room or indoor horticultural space.
It can be combined with compatible fans, carbon filters, acoustic silencers and fan-speed controllers as part of a complete ventilation and noise-management system.
How to make an extraction system quieter
Acoustic ducting works best as part of a correctly designed ventilation system. Noise can originate from the fan motor, fan vibration, turbulent airflow and air moving rapidly through undersized or restrictive ductwork.
For a quieter installation, use appropriately sized ducting, keep the ventilation route as direct as practical and avoid crushing the duct around tight corners.
Fan-speed control, vibration isolation and compatible acoustic silencers can also be considered where further noise reduction is required.
Maintaining airflow through flexible ducting
Flexible ducting should be installed carefully to avoid creating unnecessary resistance. Leaving large amounts of duct compressed together creates deeper internal corrugations and can make the airflow path more restrictive.
Extend the duct sufficiently for the required run, remove unnecessary excess length and avoid excessively tight bends. The straighter and smoother the route, the easier it is for the fan to move air through the system.
Where a sharp direction change is unavoidable, using an appropriately sized rigid metal elbow can provide a cleaner turn than forcing the flexible duct through an extremely tight bend.
Installing 152mm acoustic ducting
Measure the required ventilation route and cut the ducting to the appropriate length. Take care when cutting through the flexible inner duct, reinforcement and surrounding insulation.
When connecting to a fan, carbon filter, silencer or rigid fitting, secure the inner duct to the compatible connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the joint. Where minimising air leakage is important, suitable HVAC foil tape can also be used as part of the sealing process.
Longer runs should be adequately supported so that the weight of the insulated ducting is not left hanging directly from the fan, filter or other ventilation equipment.
Compatible 152mm / 6" ventilation equipment
This ducting is designed for nominal 152mm (6") ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of the equipment being installed. Metric and imperial ventilation sizes are commonly used together in product descriptions, but actual connection dimensions can vary slightly between manufacturers.
152mm (6") x 5m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 152mm / 6" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 152mm / 6" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, workshops & general ventilation installations |
152mm (6") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by an insulating layer designed to help reduce sound transmitted through the ventilation system. What size is this silent ducting?
It has a nominal internal duct diameter of 152mm, approximately 6 inches, and is supplied in a 5m length. Is this suitable for a 6-inch extraction fan?
Yes, provided the fan has a compatible nominal 152mm / 6" connection. Will acoustic ducting completely silence my fan?
No. It helps reduce noise transmitted through the ductwork but cannot eliminate every source of sound from a ventilation system. Is acoustic ducting quieter than normal flexible ducting?
Its insulated construction is specifically intended to reduce sound transmission compared with basic uninsulated flexible ventilation ducting. Can I use this ducting with a carbon filter?
Yes. It can connect compatible 152mm / 6" carbon filters and extraction equipment. Can acoustic ducting be used with a silencer?
Yes. Acoustic ducting and a compatible ventilation silencer can be used together where further reduction of transmitted ventilation noise is required. Can I cut the 5m length?
Yes. The ducting can be cut to suit the installation using appropriate tools, taking care when cutting the inner reinforcement and insulation. Can this ducting be used for intake ventilation?
Yes. It can be incorporated into compatible air-intake systems as well as extraction installations. Does flexible acoustic ducting affect airflow?
All ductwork creates some resistance. Keeping flexible duct reasonably extended and avoiding excessive length, compression and tight bends helps minimise additional pressure loss. Should I stretch acoustic ducting out during installation?
Extend it sufficiently for the required run rather than leaving unnecessary sections heavily compressed. This helps create a less restrictive internal airflow path. Can I bend this ducting around corners?
Yes. Its flexible construction allows it to follow changes in direction, but extremely tight bends that crush the inner duct should be avoided. How do I secure acoustic ducting?
The inner duct can be secured to compatible ventilation connections using an appropriately sized duct clamp or clip, with suitable HVAC foil tape used where additional sealing is required. Is 152mm silent ducting suitable for grow rooms?
Yes. It is particularly useful for indoor horticultural installations where 6-inch extraction equipment is used and reducing ventilation noise is desirable. What else can reduce grow room fan noise?
Correctly sized ducting, smooth airflow routes, fan-speed control, vibration isolation and compatible acoustic silencers can all contribute to a quieter ventilation installation.
£25.99
Unit price per£25.99
Unit price per152mm (6") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce the transmission of fan and airflow noise through extraction and intake systems.
Ventilation systems can transmit a considerable amount of sound through standard ducting. Noise generated by the fan, together with turbulence and fast-moving air, can travel along the duct run and become audible at the inlet or outlet.
This acoustic ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical upgrade from standard uninsulated flexible ducting where quieter ventilation is required.
With a 152mm (6") nominal internal diameter and generous 10m length, it is particularly useful for larger installations, longer duct runs or projects requiring several shorter sections of acoustic ducting.
Why choose 152mm acoustic silent ducting?
How does acoustic ducting reduce ventilation noise?
Standard flexible ducting provides an effective route for moving air but offers relatively little acoustic isolation. Sound produced by an extraction fan and turbulent airflow can therefore travel along the same route.
Acoustic ducting adds a layer of sound-absorbing insulation around the inner flexible duct. This helps reduce the amount of noise transmitted through and along the ventilation system.
It can be particularly effective on duct sections immediately before or after an extraction fan, between a carbon filter and fan, or along longer duct runs where ventilation noise would otherwise be noticeable.
Acoustic ducting should be regarded as a noise-reduction component rather than a complete silencing solution. Fan vibration, motor noise, airflow velocity and other components can also contribute to the overall sound produced by an extraction system.
Quieter 6-inch grow room ventilation
152mm-class ventilation equipment is widely used in indoor horticulture where substantial airflow is required for managing heat, humidity and air exchange.
As extraction capacity increases, fan and airflow noise can become more noticeable. Acoustic ducting helps reduce sound transmitted through the ductwork while retaining the flexibility required to route the system around the growing environment.
The 10m length makes this version particularly useful for larger grow rooms, longer extraction routes and installations where the fan or exhaust point is positioned some distance from the growing area.
Building a quieter extraction system
The best results are achieved by considering noise throughout the complete ventilation installation. Sound can originate from the fan motor, vibration, turbulent airflow and air travelling at high velocity through restrictive ductwork.
Acoustic ducting addresses sound transmitted through the duct run, while correctly sized fans and ducting help prevent excessive airflow velocity and resistance.
Where additional noise reduction is required, acoustic ducting can be combined with compatible ventilation silencers, suitable fan-speed control and vibration-isolating mounting methods.
Maintaining airflow through a 10m duct run
Longer duct runs create more resistance than short runs, so installation becomes particularly important when using a substantial length of flexible ducting.
Use only the length required and extend the flexible inner duct sufficiently to avoid unnecessary compression. Excessive internal corrugation, tight bends and crushed sections all increase resistance to airflow.
Keep the route as straight as the installation allows. Where a substantial direction change is required, an appropriately sized rigid metal elbow can provide a cleaner airflow route than forcing the flexible duct around an extremely tight corner.
When planning a long extraction run, remember that carbon filters, silencers, bends, reducers and other fittings also contribute to the total resistance the fan must overcome.
Installing 152mm acoustic ducting
Measure the required route before cutting the duct. The 10m length can be used as a longer continuous run or divided into shorter sections depending on the ventilation layout.
When connecting the ducting to a fan, carbon filter, silencer or rigid fitting, secure the inner duct to the compatible connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the joint. Where minimising air leakage is important, suitable HVAC foil tape can also be used as part of the connection and sealing process.
Longer insulated duct runs should be supported at suitable intervals. Avoid allowing the entire weight of the duct to hang directly from an extraction fan, carbon filter or other ventilation component.
Compatible 152mm / 6" ventilation equipment
This ducting is designed for nominal 152mm (6") ventilation installations and can be used alongside appropriately sized components including:
Always check the actual connection diameter of adjoining equipment before installation. Metric and imperial ventilation sizes are frequently used together in product descriptions, but exact connection dimensions can vary slightly between manufacturers.
152mm (6") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 152mm / 6" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 152mm / 6" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, workshops & general ventilation installations |
152mm (6") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by an insulating layer designed to help reduce sound transmitted through the ventilation system. What size is this silent ducting?
It has a nominal internal duct diameter of 152mm, approximately 6 inches, and is supplied in a 10m length. Is this suitable for a 6-inch extraction fan?
Yes, provided the fan has a compatible nominal 152mm / 6" connection. Will acoustic ducting completely silence my extraction fan?
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still be audible. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce sound transmission compared with basic uninsulated flexible ventilation ducting. Can I use it with a carbon filter?
Yes. It can be used with a compatible 152mm / 6" carbon filter as part of an extraction system. Can acoustic ducting be used with a ventilation silencer?
Yes. Acoustic ducting and a compatible silencer can be used together where additional reduction of transmitted ventilation noise is required. Can the 10m duct be cut into shorter lengths?
Yes. The ducting can be cut to suit the installation using suitable tools, taking care when cutting the flexible inner duct, reinforcement and insulation. Can I use this ducting for air intake?
Yes. It can be incorporated into compatible intake systems as well as extraction installations. Does a 10m duct run reduce airflow?
Longer duct runs introduce more resistance than shorter runs. The actual effect depends on the fan, installation, bends and other components, so unnecessary excess ducting should be avoided. Should acoustic ducting be stretched out?
It should be extended sufficiently for the required run rather than left heavily compressed. This helps reduce excessive internal corrugation and unnecessary airflow resistance. Can I bend the ducting around corners?
Yes. Its flexible construction allows changes in direction, but very tight bends that crush the inner duct should be avoided. How should acoustic ducting be secured?
The inner duct can be secured to compatible ventilation connections using appropriately sized duct clamps or clips, with suitable HVAC foil tape used where additional sealing is required. Is 152mm silent ducting suitable for grow rooms?
Yes. It is particularly useful for indoor horticultural installations where 6-inch extraction equipment is used and reducing ventilation noise is desirable. What else can I do to reduce grow room extraction noise?
Use correctly sized ducting, minimise unnecessary bends, isolate fan vibration and consider compatible fan-speed control and acoustic silencers where appropriate.
£11.50
Unit price per£11.50
Unit price per127mm (5") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Standard flexible ducting moves air effectively, but it can also provide a direct route for sound generated by an extraction fan and turbulent airflow. This can make ventilation equipment considerably more noticeable, particularly in enclosed indoor growing environments.
Mute Silent Ducting surrounds the flexible inner airflow duct with acoustic insulation designed to absorb transmitted sound. It is a practical upgrade from standard uninsulated ducting where quieter ventilation is a priority.
With a 127mm (5") nominal diameter and 5m length, it is ideal for compatible 5-inch fans, carbon filters and ventilation equipment used in grow rooms, propagation areas, indoor horticulture, workshops and other ventilation installations.
Why choose 127mm acoustic silent ducting?
How does acoustic ducting work?
Noise within a ventilation system does not come solely from the fan motor. Air moving through the fan, ductwork, filters and fittings can also generate sound, while the duct itself can carry noise from one part of the installation to another.
Acoustic ducting uses an insulating layer around the flexible inner duct to help absorb this transmitted sound. This makes it particularly useful on duct sections immediately before or after an extraction fan and on routes carrying exhaust air away from the growing area.
It can also be used alongside compatible acoustic silencers and suitable fan-speed controllers where a greater level of ventilation noise management is required.
Acoustic ducting reduces transmitted noise rather than making a ventilation system completely silent. Fan motor noise, vibration, airflow velocity and the overall installation all influence the final sound level.
Quieter 5-inch grow room ventilation
Extraction is essential for controlling temperature, humidity and air exchange in indoor growing environments, but continuously operating fans can become one of the most noticeable sources of background noise.
Replacing standard flexible ducting with insulated acoustic ducting helps reduce sound transmitted along the ventilation route while retaining the flexibility needed to install ductwork around grow room equipment.
The 127mm size is suited to compatible 5-inch ventilation systems and provides a useful balance between airflow capacity and physical size for smaller and medium-sized indoor horticultural installations.
Maintaining good airflow
Any ducting system creates some resistance to airflow, and flexible ducting should be installed carefully to avoid adding unnecessary restriction.
Extend the duct sufficiently for the required route rather than leaving large sections heavily compressed. This reduces excessive internal corrugation and provides a smoother route for moving air.
Keep duct runs as short and direct as practical and avoid crushing the duct or creating extremely tight bends. Where a sharp change in direction is required, a compatible rigid metal elbow can provide a cleaner turn.
Carbon filters, silencers, reducers, bends and long duct runs all add resistance to a ventilation system, so the complete installation should be considered when selecting an extraction fan.
Installing 127mm Mute Silent Ducting
Measure the required ventilation route before cutting the ducting. The 5m length can be used as a continuous run or divided into shorter sections depending on the installation.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct over the connection using an appropriately sized duct clamp or clip.
Arrange the surrounding insulation and outer covering neatly around the joint. Suitable HVAC foil tape can also be used where additional sealing is required.
Support longer sections of insulated ducting adequately rather than allowing their full weight to hang from a fan, carbon filter or other ventilation component.
Compatible 127mm / 5" ventilation equipment
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of the equipment before installation. Nominal metric and imperial ventilation sizes are commonly used together, but exact dimensions can vary slightly between manufacturers.
127mm (5") x 5m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
127mm (5") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system. What size is this silent ducting?
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 5m length. Is this suitable for a 5-inch extraction fan?
Yes, provided the fan uses a compatible nominal 127mm / 5" connection. Will acoustic ducting completely silence my fan?
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level. Is acoustic ducting quieter than normal flexible ducting?
Its insulated construction is specifically designed to reduce transmitted sound compared with basic uninsulated flexible ducting. Can I connect it to a carbon filter?
Yes. It can be used to connect compatible 127mm / 5" carbon filters, fans and other ventilation equipment. Can I use acoustic ducting with a silencer?
Yes. Acoustic ducting can be combined with a compatible ventilation silencer where additional noise reduction is required. Can I cut the 5m length?
Yes. The ducting can be cut to the required length using suitable tools, taking care when cutting the inner duct, reinforcement and insulation. Can this ducting be used for air intake?
Yes. It can be incorporated into compatible intake systems as well as extraction installations. Does flexible ducting reduce airflow?
All ductwork introduces some resistance. Keeping the duct reasonably extended and avoiding unnecessary length, compression and tight bends helps minimise additional pressure loss. Should acoustic ducting be stretched out?
Extend it sufficiently for the required run rather than leaving unnecessary sections heavily compressed. This creates a less restrictive internal airflow path. Can I bend it around corners?
Yes. Its flexible construction allows it to follow changes in direction, although excessively tight bends that crush or significantly restrict the inner duct should be avoided. How should the ducting be secured?
Use an appropriately sized duct clamp or clip to secure the inner duct to compatible fittings. Suitable HVAC foil tape can be added where further sealing is required. Is 127mm acoustic ducting suitable for grow rooms?
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable. How else can I reduce extraction fan noise?
Correctly sized ducting, smooth airflow routes, vibration isolation, suitable fan-speed control and compatible acoustic silencers can all help create a quieter ventilation system.
£21.75
Unit price per£21.75
Unit price per127mm (5") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation fans are essential for controlling temperature, humidity and air exchange, but the noise they generate can travel through standard ducting. Air movement and turbulence within the duct can also contribute to the overall sound of an extraction system.
Mute Silent Ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical alternative to standard uninsulated flexible ducting where quieter ventilation is required.
With a 127mm (5") nominal diameter and 10m length, this version is particularly useful for longer ventilation runs, larger installations or projects requiring several shorter sections of acoustic ducting.
Why choose 127mm acoustic silent ducting?
How does acoustic ducting reduce ventilation noise?
Standard flexible ducting provides an effective route for moving air, but it can also carry sound generated by the fan and turbulent airflow. That sound can travel along the duct and become audible at other points in the ventilation system.
Acoustic ducting surrounds the flexible inner duct with an insulating layer designed to help absorb transmitted sound. This can reduce the amount of fan and airflow noise carried along the duct run.
It is particularly useful on duct sections immediately before or after an extraction fan, between compatible ventilation components and on longer exhaust routes where transmitted noise may otherwise be noticeable.
Acoustic ducting is a noise-reduction component rather than a complete silencing solution. Fan motor noise, vibration, airflow velocity and the design of the overall ventilation system can all influence the final sound level.
Quieter 5-inch grow room ventilation
A correctly designed extraction system helps remove excess heat and humidity while maintaining regular air exchange within an indoor growing environment.
Where the extraction system operates continuously or for extended periods, fan and airflow noise can become particularly noticeable. Using acoustic ducting helps reduce sound transmitted through the ductwork while retaining the flexibility needed for practical grow room installations.
The 10m length is especially useful where the extraction point is positioned some distance from the growing area or where several sections of 127mm acoustic ducting are required within the same installation.
Maintaining airflow through a 10m duct run
Longer duct runs create more airflow resistance than short, direct installations. For this reason, careful routing becomes increasingly important when using a substantial length of flexible ducting.
Use only the length required and extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This helps reduce excessive internal corrugation and provides a less restrictive path for moving air.
Avoid crushed sections and very tight bends wherever possible. Where a significant change in direction is required, an appropriately sized rigid elbow can provide a cleaner airflow route than forcing flexible ducting around an extremely tight corner.
Carbon filters, silencers, reducers, bends and other fittings also add resistance. The complete duct route should therefore be considered when selecting and setting up an extraction fan.
Installing 127mm Mute Silent Ducting
Measure the required route before cutting the ducting. The full 10m length can be used for a longer continuous run or divided into shorter sections depending on the ventilation layout.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct to the connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the connection. Suitable HVAC foil tape can also be used where additional sealing is required.
Longer insulated duct runs should be supported at suitable intervals. Avoid allowing the full weight of the ducting to hang directly from a fan, carbon filter or other ventilation component.
Compatible 127mm / 5" ventilation equipment
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of adjoining equipment before installation. Nominal metric and imperial ventilation sizes are frequently used together, but exact connection dimensions can vary slightly between manufacturers.
127mm (5") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
127mm (5") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system. What size is this ducting?
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 10m length. Is this suitable for a 5-inch extraction fan?
Yes, provided the fan has a compatible nominal 127mm / 5" connection. Will acoustic ducting completely silence an extraction fan?
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted sound compared with basic uninsulated flexible ventilation ducting. Can I connect this ducting to a carbon filter?
Yes. It can be used with compatible 127mm / 5" carbon filters, extraction fans and other appropriately sized ventilation components. Can it be used with an acoustic silencer?
Yes. Acoustic ducting and a compatible ventilation silencer can be used together where further reduction of transmitted ventilation noise is required. Can I cut the 10m duct into shorter sections?
Yes. The ducting can be cut to suit the installation using suitable tools, taking care when cutting the flexible inner duct, reinforcement and surrounding insulation. Can this ducting be used for air intake?
Yes. It can be incorporated into compatible intake systems as well as extraction installations. Does a 10m duct run affect airflow?
Longer duct runs create more resistance than short runs. The actual effect depends on the fan, bends, filters and other components, so unnecessary excess ducting should be avoided. Should acoustic ducting be fully extended?
It should be extended sufficiently for the required route rather than left heavily compressed. This helps reduce excessive internal corrugation and unnecessary airflow resistance. Can I bend the ducting around corners?
Yes. Its flexible construction allows changes in direction, although very tight bends that crush or significantly restrict the inner duct should be avoided. How should the ducting be secured?
Secure the inner duct to compatible fittings using an appropriately sized duct clamp or clip. Suitable HVAC foil tape can be added where further sealing is required. Is 127mm acoustic ducting suitable for grow rooms?
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable. How else can I reduce grow room extraction noise?
Use correctly sized ducting, minimise unnecessary bends, isolate fan vibration and consider suitable fan-speed control and compatible acoustic silencers where appropriate.
£10.45
Unit price per£10.45
Unit price per102mm (4") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Standard flexible ducting provides a convenient route for moving air, but it can also transmit noise generated by an extraction fan and turbulent airflow. In smaller indoor growing environments, where ventilation equipment is often positioned relatively close to the growing area, this noise can be particularly noticeable.
Mute Silent Ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical upgrade from standard uninsulated ducting where quieter ventilation is required.
With a 102mm (4") nominal diameter and 5m length, this version is ideal for compatible 4-inch extraction fans, carbon filters and ventilation equipment used in smaller grow rooms, grow tents, propagation areas and other indoor ventilation installations.
Why choose 102mm acoustic silent ducting?
How does acoustic ducting reduce noise?
Ventilation noise can originate from several sources. The fan motor itself produces sound, while the movement of air through the fan, ducting, filters and fittings can create additional turbulence and noise.
Standard ducting can carry this sound along the ventilation route. Acoustic ducting adds an insulating layer around the flexible inner duct to help absorb transmitted noise before it travels through the system.
This makes it particularly useful immediately before or after an extraction fan, between compatible ventilation components and along exhaust routes where sound from the ventilation system would otherwise be noticeable.
Acoustic ducting is designed to reduce transmitted noise rather than make an extraction system completely silent. Fan vibration, motor noise, airflow velocity and the overall system design can still influence the final sound level.
Quieter 4-inch grow room and grow tent ventilation
102mm-class ventilation equipment is commonly used in smaller indoor horticultural installations where heat, humidity and stale air need to be removed without installing unnecessarily large extraction equipment.
In a compact grow tent or propagation area, the fan and ducting are often located relatively close to the growing space. This can make ventilation noise more apparent than it would be in a larger installation.
Using acoustic ducting helps reduce sound transmitted along the ventilation route while retaining the flexibility required to route ductwork through tent ports, around equipment and towards the extraction point.
Maintaining good airflow
Good duct installation is important for maintaining the performance of any extraction system. Flexible ducting should be routed as directly as practical and unnecessary restrictions should be avoided.
Extend the duct sufficiently for the required route rather than leaving large sections heavily compressed. This reduces excessive internal corrugation and provides a smoother route for moving air.
Avoid crushing the duct and minimise very tight bends. Every bend, carbon filter, silencer, reducer and length of duct adds resistance to the system, so keeping the airflow path straightforward helps the fan operate effectively.
This is particularly relevant with 102mm systems, where restrictive routing can have a noticeable effect on the airflow available from a smaller extraction fan.
Installing 102mm Mute Silent Ducting
Measure the required ventilation route before cutting. The 5m length can be installed as one continuous run or divided into shorter sections depending on the layout.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct over the connection using an appropriately sized duct clamp or clip.
Arrange the surrounding insulation and outer covering neatly around the connection. Suitable HVAC foil tape can also be used where additional sealing is required.
Support longer sections of insulated ducting rather than allowing their full weight to hang directly from the extraction fan, carbon filter or another ventilation component.
Compatible 102mm / 4" ventilation equipment
This ducting is intended for nominal 102mm (4") round ventilation systems and can be used with appropriately sized components including:
Always check the actual connection diameter of adjoining equipment before installation. Nominal metric and imperial ventilation sizes are commonly used together, but exact connection dimensions can vary slightly between manufacturers.
102mm (4") x 5m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 102mm / 4" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 102mm / 4" round ventilation systems |
| Suitable applications | Grow tents, grow rooms, propagation areas, indoor horticulture & general ventilation installations |
102mm (4") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system. What size is this silent ducting?
It has a nominal diameter of 102mm, approximately 4 inches, and is supplied in a 5m length. Is this suitable for a 4-inch extraction fan?
Yes, provided the fan has a compatible nominal 102mm / 4" connection. Is this suitable for a grow tent?
Yes. Its 102mm nominal diameter makes it particularly useful with compatible 4-inch ventilation equipment used in smaller grow tents and indoor growing environments. Will acoustic ducting completely silence my extraction fan?
No. It helps reduce sound transmitted through the ductwork, but motor noise, vibration and airflow can still contribute to the overall noise produced by the system. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted sound compared with basic uninsulated flexible ventilation ducting. Can I connect it to a carbon filter?
Yes. It can be used with compatible 102mm / 4" carbon filters, extraction fans and other appropriately sized ventilation equipment. Can acoustic ducting be used with a silencer?
Yes. It can be combined with a compatible ventilation silencer where additional reduction of transmitted ventilation noise is required. Can the 5m duct be cut into shorter sections?
Yes. The ducting can be cut to suit the installation using suitable tools, taking care when cutting the inner duct, reinforcement and surrounding insulation. Can this ducting be used for air intake?
Yes. It can be incorporated into compatible intake systems as well as extraction installations. Does flexible ducting reduce airflow?
All ductwork introduces some resistance. Keeping the duct reasonably extended and avoiding unnecessary length, compression and tight bends helps minimise additional pressure loss. Should acoustic ducting be stretched out?
It should be extended sufficiently for the required route rather than left heavily compressed. This helps provide a less restrictive internal airflow path. Can I bend it around corners?
Yes. Its flexible construction allows changes in direction, although very tight bends that crush or significantly restrict the inner duct should be avoided. How should 4-inch acoustic ducting be secured?
Secure the inner duct to compatible fittings using an appropriately sized duct clamp or clip. Suitable HVAC foil tape can be used where additional sealing is required. What else can help reduce grow room extraction noise?
Correctly sized ducting, smooth airflow routes, vibration isolation, suitable fan-speed control and compatible acoustic silencers can all contribute to a quieter ventilation system.
£19.25
Unit price per£19.25
Unit price per102mm (4") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation is essential for controlling temperature, humidity and air quality, but conventional flexible ducting can transmit noise generated by extraction fans and fast-moving air. This insulated ducting provides a practical solution for installations where quieter ventilation is required.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb transmitted sound. This makes it particularly useful in grow rooms, grow tents and other indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied as a generous 10 metre length, this 102mm version can be used as a continuous duct run or cut into shorter sections to suit the ventilation layout. It is designed for use with compatible 4-inch extraction fans, carbon filters and ventilation fittings.
Why choose 102mm acoustic silent ducting?
How does acoustic ducting help reduce noise?
An extraction system can produce noise from the fan motor, vibration and the movement of air through filters, ducting and fittings. Some of this sound can travel along ordinary ductwork and become noticeable at the intake or exhaust end of the system.
Acoustic ducting surrounds the flexible inner air passage with insulation. This layer helps absorb sound transmitted through the duct rather than allowing it to travel as freely along the ventilation route.
It can be particularly useful on duct runs immediately before or after an extraction fan, between compatible ventilation components and along exhaust routes where reducing transmitted ventilation noise is desirable.
Acoustic ducting is designed to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, airflow velocity, vibration, duct routing and the overall extraction system will all affect the final noise level.
Quieter grow room and grow tent ventilation
In an indoor growing environment, extraction systems may run for long periods to manage heat and humidity and maintain a regular exchange of air. This can make ventilation noise one of the most noticeable parts of the environmental control system.
Acoustic ducting is a straightforward way of addressing noise transmitted through the ductwork without changing the basic operation of the extraction system.
The 102mm / 4" diameter is particularly suited to compatible smaller ventilation installations, while the 10m length provides additional flexibility for longer routes or installations requiring several individual sections of duct.
Getting the best airflow from flexible ducting
Correct installation is important because every length of ducting and every bend adds resistance to the ventilation system. The more resistance the fan has to overcome, the lower its effective airflow can become.
Extend flexible ducting sufficiently for the required route rather than leaving large sections heavily compressed. This reduces unnecessary internal corrugation and creates a smoother path for moving air.
Keep the route as direct as practical and avoid crushing the duct or introducing unnecessary tight bends. Where a major change in direction is required, a smooth bend generally provides a better airflow path than sharply folding the flexible duct.
A 10m roll does not need to be used in its entirety. If the installation only requires a shorter route, cutting the duct to the appropriate length can help avoid unnecessary resistance.
Installing 102mm Mute Silent Ducting
Plan the ventilation route before installation and determine how much ducting is actually required. The 10m roll can then be cut into the appropriate lengths for the system.
When connecting the duct to a compatible fan, carbon filter or rigid fitting, secure the inner flexible duct around the connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the completed connection. Suitable HVAC foil tape can also be used where additional sealing is required.
Longer sections should be adequately supported. Avoid allowing the full weight of a long insulated duct run to hang directly from the extraction fan, carbon filter or another ventilation component.
Compatible 102mm / 4" ventilation equipment
This ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of adjoining equipment before installation. Nominal metric and imperial ventilation sizes are commonly used together, but exact connection dimensions can vary slightly between products.
102mm (4") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 102mm / 4" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 102mm / 4" round ventilation systems |
| Suitable applications | Grow tents, grow rooms, propagation areas, indoor horticulture & general ventilation installations |
102mm (4") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ductwork. What size is this ducting?
This version has a nominal diameter of 102mm, approximately 4 inches, and is supplied in a 10m length. Is it suitable for a 4-inch extraction fan?
Yes, provided the extraction fan has a compatible nominal 102mm / 4" duct connection. Can I use this with a 4-inch carbon filter?
Yes. It can be connected to compatible 102mm / 4" carbon filters as part of an appropriately designed extraction system. Is acoustic ducting suitable for grow tents?
Yes. It is particularly useful where reducing the amount of ventilation noise transmitted through grow tent ducting is important. Will it make my extraction fan silent?
No. Acoustic ducting helps reduce sound transmitted through the ductwork, but it cannot eliminate fan motor noise, vibration or all airflow noise. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted ventilation sound compared with basic uninsulated flexible ducting. Can I cut the 10m roll into shorter lengths?
Yes. The duct can be cut to suit the individual ventilation layout, making a 10m roll useful for either a longer route or several shorter sections. Can this ducting be used for intake air?
Yes. It can be used in compatible air-intake installations as well as extraction systems. Can it be used with a ventilation silencer?
Yes. Acoustic ducting can be combined with a compatible silencer where additional control of transmitted ventilation noise is required. Does flexible ducting affect airflow?
All ductwork creates some airflow resistance. Excessive length, tight bends and heavily compressed flexible ducting can increase that resistance, so a direct and properly extended installation is preferable. Should I use the full 10 metres?
Only if the installation requires it. Using the shortest practical duct route generally helps minimise airflow resistance. Can the ducting be bent around obstacles?
Yes. The flexible construction allows it to be routed around equipment, although sharp bends and crushed sections should be avoided. How should the ducting be attached to ventilation equipment?
The inner duct should be secured to the compatible connection using an appropriately sized duct clamp or clip. Suitable HVAC foil tape can be used where additional sealing is required. How else can I reduce extraction-system noise?
Good duct routing, vibration isolation, appropriately sized fans, suitable fan-speed control and compatible ventilation silencers can all help reduce overall system noise.
£25.65
Unit price per£25.65
Unit price per317mm (12.5") x 5m Mute Silent Ducting is a large-diameter acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through high-volume extraction and intake systems.
Large extraction systems can move substantial volumes of air, but increased airflow can also make ventilation noise more noticeable. This insulated ducting provides a practical way to reduce sound transmission through the ductwork while maintaining the flexibility required for installation around fans, filters and other ventilation equipment.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb transmitted sound. This makes it particularly useful for larger grow rooms, horticultural facilities and other controlled environments where powerful ventilation equipment may operate for extended periods.
Supplied as a 5 metre length with a nominal 317mm / 12.5" diameter, it can be used as a continuous duct run or cut into shorter sections to suit the ventilation layout.
Why choose 317mm acoustic silent ducting?
How does acoustic ducting reduce ventilation noise?
Ventilation noise can originate from several sources, including the extraction fan itself, vibration and turbulent air moving through filters, bends and ductwork. Some of this sound can travel through ordinary flexible ducting and become noticeable elsewhere in the ventilation system.
Acoustic ducting surrounds the flexible inner air passage with insulation designed to absorb transmitted sound. This helps limit the amount of fan and airflow noise travelling along the duct route.
It is particularly useful immediately before or after extraction fans, between compatible ventilation components and along exhaust routes where reducing transmitted noise is desirable.
Acoustic ducting is designed to reduce noise rather than make an extraction system completely silent. Fan design, airflow velocity, vibration, duct length, bends and installation quality all influence the final sound level.
Large-diameter ducting for grow room ventilation
Larger indoor growing environments can require substantial airflow to remove excess heat and humidity and maintain a regular exchange of air. High-capacity extraction fans and carbon filters therefore commonly require larger-diameter ductwork.
The generous 317mm diameter allows this ducting to be paired with compatible large ventilation equipment while the acoustic insulation helps control noise travelling through the system.
It can be used for both extraction and intake routes, making it suitable for building complete ventilation systems in grow rooms and other indoor horticultural environments.
Maintaining efficient airflow
Correct duct installation is particularly important with high-volume ventilation systems. Every metre of duct, bend and fitting creates resistance that the extraction fan must overcome.
Extend flexible ducting sufficiently rather than leaving long sections heavily compressed. A properly extended duct creates a smoother internal airflow path and reduces unnecessary resistance.
Keep the route as short and direct as practical. Avoid crushing the duct, creating excessively tight bends or leaving unnecessary lengths coiled within the installation.
If the full 5m length is not required, the ducting can be cut to the appropriate length for the installation.
Installing 317mm Mute Silent Ducting
Plan the complete ventilation route before cutting or installing the duct. Check that the fan, filter and any connectors or fittings are compatible with the nominal 317mm / 12.5" duct size.
Connect the inner flexible duct securely around the equipment connection using a suitably sized duct clamp or fixing. Suitable HVAC foil tape can be used where additional sealing is required.
Arrange the insulation and outer covering neatly around the completed connection to maintain the acoustic layer as effectively as possible.
Because large-diameter insulated ducting can become relatively bulky over longer runs, provide suitable support rather than allowing its full weight to hang directly from a fan, carbon filter or other ventilation component.
Compatible ventilation equipment
The ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of adjoining equipment before installation. Nominal ventilation sizes and the exact outside diameter of individual fittings can vary slightly between manufacturers.
317mm (12.5") x 5m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
317mm (12.5") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ductwork. What size is this ducting?
This version has a nominal diameter of 317mm, approximately 12.5 inches, and is supplied in a 5m length. What is 317mm ducting used for?
Its large diameter makes it suitable for compatible high-volume ventilation systems used in larger grow rooms and other environments requiring substantial extraction or intake airflow. Does acoustic ducting make an extraction system silent?
No. It helps reduce sound transmitted through the ductwork but cannot completely eliminate fan motor noise, vibration or airflow noise. Is it quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting. Can I connect it to a carbon filter?
Yes, provided the carbon filter connection is compatible with the nominal 317mm / 12.5" duct size. Can I use it with an extraction fan?
Yes. It is designed for use as part of a compatible ventilation system and can be connected to appropriately sized extraction equipment. Can this ducting be used for air intake?
Yes. It can be used for compatible intake systems as well as extraction ductwork. Can the 5m duct be cut?
Yes. It can be cut into the length or individual sections required for the ventilation installation. Does the length of ducting affect airflow?
Yes. Longer duct runs create additional resistance, so using the shortest practical route can help maintain effective airflow. Do bends in ducting reduce airflow?
Bends increase resistance, particularly when they are sharp or tightly compressed. Smooth, gradual changes in direction are preferable wherever possible. Should flexible ducting be fully stretched?
It should be sufficiently extended for the required route rather than left heavily compressed, as excessive internal corrugation can increase airflow resistance. How should large acoustic ducting be supported?
Use suitable supports along the duct route so that the weight of the ducting is not carried entirely by the extraction fan, filter or connecting fittings. Can acoustic ducting be used with a ventilation silencer?
Yes. Combining acoustic ducting with a compatible ventilation silencer can provide additional control of sound transmitted through an extraction system. What else can help reduce grow room extraction noise?
Good duct routing, suitable fan sizing, vibration isolation, appropriate fan-speed control and compatible silencers can all contribute to a quieter ventilation installation.
£57.50
Unit price per£57.50
Unit price per317mm (12.5") x 10m Mute Silent Ducting is a large-diameter acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through high-volume extraction and intake systems.
Large ventilation systems can move substantial volumes of air, but powerful extraction fans and high airflow rates can also generate noticeable noise. This insulated ducting provides a practical way to reduce sound transmission through the ductwork while retaining the flexibility required for routing around fans, filters and other ventilation equipment.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb transmitted sound. This makes it particularly useful for larger grow rooms, indoor horticultural facilities and other controlled environments where high-capacity ventilation equipment may operate for extended periods.
Supplied as a generous 10 metre length with a nominal 317mm / 12.5" diameter, it is well suited to longer ventilation routes and can also be cut into shorter sections where required.
Why choose 317mm acoustic silent ducting?
How does acoustic ducting help reduce noise?
Ventilation noise can originate from the extraction fan, vibration and turbulent air moving through filters, fittings and ductwork. Some of this sound can travel along ordinary flexible ducting and become noticeable at other points in the ventilation system.
Acoustic ducting surrounds the flexible inner air passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling along the duct route.
It can be particularly useful immediately before or after powerful extraction fans, between compatible ventilation components and along exhaust routes where controlling transmitted sound is important.
Acoustic ducting is designed to reduce transmitted ventilation noise rather than make a system completely silent. Fan design, airflow velocity, vibration, duct routing and installation quality all influence the final sound level.
Large-diameter ducting for high-volume grow room ventilation
Larger indoor growing environments can require substantial airflow to remove excess heat and humidity and maintain a regular exchange of air. High-capacity extraction systems therefore commonly use larger fans, filters and ductwork.
The 317mm / 12.5" diameter makes this ducting suitable for compatible large-scale ventilation installations, while the acoustic insulation helps control the noise transmitted through the ductwork.
The 10m length is particularly useful for larger rooms, longer exhaust routes and installations where several sections of acoustic ducting are required.
Maintaining efficient airflow
Correct duct installation is important in any extraction system, particularly where large volumes of air are being moved. Every metre of ducting, bend and fitting creates resistance that the ventilation fan must overcome.
Extend flexible ducting sufficiently rather than leaving large sections heavily compressed. A properly extended duct provides a smoother internal airflow path and reduces unnecessary resistance.
Keep the route as short and direct as the installation allows. Avoid crushing the duct, creating excessively tight bends or leaving unnecessary lengths coiled within the ventilation system.
Although this product provides 10m of ducting, there is no requirement to use the complete length in a single run. Cutting the duct to the required length can help keep the system efficient.
Installing 317mm Mute Silent Ducting
Plan the ventilation route before cutting the duct and check that the fan, filter and any connectors or fittings are compatible with the nominal 317mm / 12.5" size.
Connect the inner flexible duct securely around the compatible ventilation connection using a suitably sized duct clamp or fixing. Suitable HVAC foil tape can be used where additional sealing is required.
Arrange the insulation and outer covering neatly around the completed connection so the acoustic layer remains as continuous as practical.
Large-diameter insulated ducting can become relatively bulky over a long run. Provide suitable support along the route rather than allowing the entire weight of the duct to hang directly from the extraction fan, carbon filter or another ventilation component.
Compatible ventilation equipment
This ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of adjoining equipment before installation. Nominal ventilation sizes and the exact outside diameter of individual fittings can vary slightly between manufacturers.
317mm (12.5") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible high-volume ventilation installations |
317mm (12.5") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ductwork. What size is this ducting?
This version has a nominal diameter of 317mm, approximately 12.5 inches, and is supplied in a 10m length. What is 317mm ducting used for?
Its large diameter makes it suitable for compatible high-volume ventilation systems used in larger grow rooms and other environments requiring substantial extraction or intake airflow. Does acoustic ducting make an extraction system silent?
No. It helps reduce sound transmitted through the ductwork but cannot completely eliminate fan motor noise, vibration or airflow noise. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting. Can I connect it to a carbon filter?
Yes, provided the carbon filter connection is compatible with the nominal 317mm / 12.5" duct size. Can I use it with an extraction fan?
Yes. It can be connected to appropriately sized extraction equipment as part of a compatible ventilation system. Can this ducting be used for air intake?
Yes. It can be used for compatible intake systems as well as extraction ductwork. Can I cut the 10m roll into shorter lengths?
Yes. The duct can be cut to suit the installation, allowing the roll to be used for one long ventilation route or several shorter sections. Should I use the entire 10m length?
Only where the installation requires it. Using the shortest practical duct route generally helps minimise airflow resistance. Does duct length affect extraction performance?
Yes. Longer duct runs create additional resistance, particularly when combined with multiple bends and fittings. Do bends in ducting reduce airflow?
Bends increase resistance, especially when they are sharp or tightly compressed. Smooth, gradual changes in direction are preferable wherever possible. Should flexible ducting be fully extended?
It should be sufficiently extended for the required route rather than left heavily compressed, as excessive internal corrugation can increase airflow resistance. How should a long run of acoustic ducting be supported?
Use suitable supports along the route so that the weight of the ducting is not carried entirely by the extraction fan, carbon filter or connecting fittings. What else can help reduce extraction-system noise?
Good duct routing, suitable fan sizing, vibration isolation, appropriate fan-speed control and compatible ventilation silencers can all contribute to a quieter ventilation installation.
£47.50
Unit price per£47.50
Unit price per254mm (10") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in high-capacity extraction and intake systems.
Powerful ventilation equipment can generate considerable noise from both the fan and the movement of air through the ductwork. This insulated ducting provides a practical way to reduce sound transmission while retaining the flexibility and straightforward installation of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound travelling along the ventilation system. This makes it particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a generous 10 metre length with a nominal 254mm / 10" diameter, the duct can be used as one extended run or cut into shorter sections to suit the installation.
Why choose 254mm acoustic silent ducting?
How does acoustic ducting reduce ventilation noise?
Ventilation noise does not only originate directly from an extraction fan. Fan sound, vibration and turbulent airflow can travel through ordinary ductwork and become audible at other points in the ventilation route.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling along the duct run.
It can be particularly useful immediately before or after an extraction fan, between a fan and carbon filter, or along longer ventilation routes where transmitted sound needs to be controlled.
Acoustic ducting is designed to reduce ventilation noise rather than make an extraction system completely silent. Fan design, fan speed, airflow velocity, vibration, duct routing and installation quality will all influence the final noise level.
Designed for high-capacity grow room ventilation
Larger grow rooms and controlled horticultural environments can require substantial air movement to manage heat, humidity and general air exchange. As ventilation capacity increases, controlling the associated noise becomes increasingly important.
The 254mm / 10" diameter is suitable for compatible high-volume extraction equipment, while the insulated construction helps reduce sound transmitted through the ducting.
It can be incorporated into complete ventilation systems using compatible inline fans, carbon filters, metal duct fittings, reducers, bends and other appropriately sized components.
Maintaining good airflow through flexible ducting
Correct installation is important because every length of duct, bend and fitting introduces resistance to airflow. This becomes especially relevant with longer ventilation runs.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. A more fully extended inner duct provides a smoother airflow path and can help reduce avoidable turbulence and resistance.
Keep the route as short and direct as the installation allows. Avoid crushing the duct and minimise tight bends, with gradual changes in direction preferable wherever possible.
Although this product provides 10 metres of ducting, there is no requirement to use the full length. Cutting each section to the amount actually required can help create a cleaner and more efficient ventilation installation.
Installing 254mm Mute Silent Ducting
Check that the fan, carbon filter and other ventilation fittings have compatible nominal 254mm / 10" connections before installation.
Fit the flexible inner duct securely over the ventilation connection and fasten it using an appropriately sized duct clamp or suitable fixing. HVAC foil tape can be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed joint so that the insulating layer remains as continuous as practical.
Long duct runs should be supported at suitable intervals. Avoid allowing the full weight of a long section of ducting to hang directly from the extraction fan, carbon filter or another ventilation component.
Compatible ventilation equipment
Always check the actual connection dimensions of individual components before installation, as nominal sizes and connection details can vary between ventilation equipment manufacturers.
254mm (10") x 10m Mute Silent Ducting product details
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
254mm (10") Mute Silent Ducting FAQs
What is acoustic ducting?
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system. What size is this ducting?
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 10 metre length. Is this suitable for a 10-inch extraction fan?
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Check the fan connection dimensions before installation. Can it be connected to a 10-inch carbon filter?
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of an appropriately sized extraction system. Does acoustic ducting make an extraction fan silent?
No. Acoustic ducting helps reduce noise transmitted through the ductwork, but it cannot completely eliminate fan motor noise, vibration or the sound created by moving air. Is acoustic ducting quieter than standard flexible ducting?
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting. Can this ducting be used for intake as well as extraction?
Yes. It can be incorporated into compatible fresh-air intake systems as well as extraction systems. Can I cut the 10m duct into shorter lengths?
Yes. The ducting can be cut to suit the installation, making the 10m version useful when several individual duct sections are required. Do I need to use the entire 10 metre length?
No. Use only the amount required. Keeping ventilation routes reasonably short and direct generally helps minimise unnecessary resistance. Does a longer duct run reduce airflow?
Longer duct runs introduce additional resistance. Bends, fittings and compressed flexible duct can add further resistance, so ventilation systems should be planned with the total duct route in mind. Do bends in the duct affect extraction performance?
Yes. Tight bends can increase airflow resistance, so smooth and gradual changes in direction are preferable where the installation allows. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the required run rather than left unnecessarily compressed. This helps provide a smoother internal path for airflow. Where is the best place to use acoustic ducting?
It can be used throughout a compatible ventilation route. Sections immediately around powerful extraction fans can be particularly useful where reducing transmitted fan noise is a priority. Does a 10m run need supporting?
Yes. Longer duct runs should be supported appropriately rather than allowing their weight to hang entirely from the fan, filter or connecting fittings. How can I make a grow room extraction system quieter?
Acoustic ducting can form part of a quieter installation alongside sensible duct routing, correctly sized fans and filters, vibration isolation, suitable fan-speed control and ventilation silencers.
£8.95
Unit price per£8.95
Unit price per203mm (8") x 5m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce noise transmission while moving air through horticultural extraction and intake systems.
Ventilation fans generate both mechanical noise and sound from the movement of air. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting uses an insulating layer around the inner duct to help absorb transmitted sound.
This makes acoustic ducting particularly useful for indoor horticulture and controlled growing environments where extraction equipment may operate for long periods and keeping fan and airflow noise under control is important.
Supplied in a 5 metre length with a nominal 203mm / 8" diameter, it can be used with compatible fans, carbon filters and 8-inch ventilation fittings. The flexible construction allows it to be routed around equipment and cut to the required length during installation.
Why choose 203mm acoustic ducting?
How does acoustic ducting work?
A horticultural ventilation system can produce noise from several sources. The fan motor itself creates sound, while fast-moving air can generate additional noise and turbulence as it passes through the ducting.
Acoustic ducting incorporates an insulating layer around the flexible inner air passage. This insulation helps absorb sound energy that would otherwise travel along the ductwork, reducing the amount of ventilation noise transmitted through the system.
It can be particularly useful close to an extraction fan, between a fan and carbon filter, and along sections of duct where transmitted noise would otherwise be noticeable.
Acoustic ducting is designed to reduce noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow, vibration and the layout of the ductwork will all affect the overall noise level.
Ideal for horticultural extraction systems
Effective ventilation is essential for managing temperature, humidity and air exchange in indoor horticultural environments. However, moving large quantities of air can make extraction systems one of the main sources of environmental-control noise.
Replacing basic uninsulated ducting with acoustic ducting can help control the amount of sound transmitted through the ventilation route while still providing a flexible connection between compatible components.
The 203mm / 8" size is suitable for appropriately sized medium to high-capacity ventilation systems using compatible inline fans, carbon filters and duct fittings.
Getting the best airflow from acoustic ducting
Correct duct installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, as excessive compression creates a less efficient internal airflow path.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction increase resistance and can reduce the effective airflow delivered by the extraction fan.
Where a change of direction is required, use a gradual bend wherever possible. The 5m duct can also be cut down so that only the length actually required is installed.
Installing 203mm acoustic ducting
Before installation, confirm that the fan, carbon filter and other ventilation components have compatible nominal 203mm / 8" connections.
Fit the flexible inner duct securely over the connection and fasten it using a suitable duct clamp or fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the joint so that the acoustic layer remains as continuous as practical.
Support longer sections of ducting appropriately rather than allowing their full weight to hang directly from a fan, carbon filter or other ventilation component.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as dimensions can vary slightly between manufacturers.
203mm (8") x 5m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 203mm / 8" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 203mm / 8" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, controlled growing environments & compatible ventilation installations |
203mm (8") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal 203mm / 8" diameter and is supplied in a 5 metre length. Is this suitable for an 8-inch extraction fan?
Yes, provided the fan has a compatible nominal 203mm / 8" duct connection. Can I use it with an 8-inch carbon filter?
Yes. It can be used to connect compatible 203mm / 8" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not eliminate noise produced directly by the fan itself. Is acoustic ducting quieter than ordinary ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where noise reduction is a priority. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural extraction systems where temperature, humidity and air exchange need to be managed while keeping ventilation noise under control. Can it also be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 5m length?
Yes. The duct can be cut to suit the required ventilation route or divided into shorter sections. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends reduce airflow?
Yes. Tight bends increase resistance and turbulence, so gradual changes in direction are preferable wherever possible. Does longer ducting affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. Where should acoustic ducting be installed?
It can be used throughout a compatible ventilation route. Sections around the extraction fan are particularly useful where transmitted fan noise is a concern. How should acoustic ducting be secured?
Use appropriately sized duct clamps or suitable ventilation fixings, with HVAC foil tape where additional sealing is required. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£16.99
Unit price per£16.99
Unit price per203mm (8") x 10m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce noise transmission while moving air through extraction and intake systems.
Ventilation fans generate both mechanical noise and sound from the movement of air. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting uses an insulating layer around the inner duct to help absorb transmitted sound.
This makes acoustic ducting particularly useful for indoor horticulture and controlled growing environments where extraction equipment may operate for long periods and keeping fan and airflow noise under control is important.
Supplied in a generous 10 metre length with a nominal 203mm / 8" diameter, it can be used with compatible fans, carbon filters and ventilation fittings. The flexible construction allows it to be routed around equipment and cut into the exact lengths required for the installation.
Why choose 203mm acoustic ducting?
How does acoustic ducting work?
A ventilation system can produce noise from several sources. The fan motor itself creates sound, while fast-moving air can generate additional noise and turbulence as it passes through the ducting.
Acoustic ducting incorporates an insulating layer around the flexible inner air passage. This insulation helps absorb sound energy that would otherwise travel along the ductwork, reducing the amount of ventilation noise transmitted through the system.
It can be particularly useful close to an extraction fan, between a fan and carbon filter, and along longer sections of duct where transmitted noise would otherwise be noticeable.
Acoustic ducting is designed to reduce noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow, vibration and the layout of the ductwork will all affect the overall noise level.
Ideal for horticultural extraction systems
Effective ventilation is essential for managing temperature, humidity and air exchange in indoor horticultural environments. However, moving large quantities of air can make extraction systems one of the main sources of environmental-control noise.
Replacing basic uninsulated ducting with acoustic ducting can help control the amount of sound transmitted through the ventilation route while still providing a flexible connection between compatible components.
The 203mm / 8" size is suitable for appropriately sized medium to high-capacity ventilation systems using compatible inline fans, carbon filters and duct fittings.
The 10m length is particularly useful for larger growing areas, longer ventilation routes or installations requiring several individual sections of acoustic ducting.
Getting the best airflow from acoustic ducting
Correct duct installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, as excessive compression creates a less efficient internal airflow path.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction increase resistance and can reduce the effective airflow delivered by the extraction fan.
Where a change of direction is required, use a gradual bend wherever possible. Although 10 metres of ducting is supplied, there is no requirement to use the complete length in one continuous run.
Cutting each section to the length actually required can help minimise unnecessary airflow resistance while leaving the remaining duct available for other parts of the ventilation installation.
Installing 203mm acoustic ducting
Before installation, confirm that the fan, carbon filter and other ventilation components have compatible nominal 203mm / 8" connections.
Fit the flexible inner duct securely over the connection and fasten it using a suitable duct clamp or fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the joint so that the acoustic layer remains as continuous as practical.
Longer sections of ducting should be supported appropriately rather than allowing their full weight to hang directly from a fan, carbon filter or other ventilation component.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as dimensions can vary slightly between manufacturers.
203mm (8") x 10m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 203mm / 8" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 203mm / 8" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, controlled growing environments & compatible ventilation installations |
203mm (8") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal 203mm / 8" diameter and is supplied in a 10 metre length. Is this suitable for an 8-inch extraction fan?
Yes, provided the fan has a compatible nominal 203mm / 8" duct connection. Can I use it with an 8-inch carbon filter?
Yes. It can be used to connect compatible 203mm / 8" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not eliminate noise produced directly by the fan itself. Is acoustic ducting quieter than ordinary ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where noise reduction is a priority. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural extraction systems where temperature, humidity and air exchange need to be managed while keeping ventilation noise under control. Can it also be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 10m length?
Yes. The duct can be cut to suit the required ventilation route or divided into several shorter sections. Do I need to use the full 10 metres?
No. Use only the amount required for the installation. Keeping duct routes reasonably short and direct generally helps minimise unnecessary airflow resistance. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends reduce airflow?
Yes. Tight bends increase resistance and turbulence, so gradual changes in direction are preferable wherever possible. Does a longer duct run affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. How should a long run of acoustic ducting be supported?
Longer runs should be supported at suitable intervals so that the weight of the duct is not carried entirely by the fan, filter or connecting fittings. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£5.99
Unit price per£5.99
Unit price per127mm (5") x 5m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation fans generate sound from both the fan itself and the movement of air through the system. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted sound.
This makes it particularly useful for indoor horticulture, propagation areas and controlled growing environments where ventilation equipment may operate for extended periods and reducing unnecessary noise is desirable.
Supplied in a 5 metre length with a nominal 127mm / 5" diameter, it can be connected to compatible fans, carbon filters and ventilation fittings. The flexible construction allows the duct to be routed around equipment and cut to the required length during installation.
Why choose 127mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. Some of this sound can travel along ordinary flexible duct and become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct route.
It can be particularly useful around extraction fans, between compatible fans and carbon filters, and along sections of ventilation duct where transmitted noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Acoustic ducting for indoor horticulture
Reliable ventilation helps manage temperature, humidity and air exchange within controlled growing environments. Extraction and intake equipment can, however, become a significant source of noise when operating continuously or at higher fan speeds.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect ventilation equipment and route air around an installation.
The 127mm / 5" size is suitable for compatible ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
Getting the best airflow from acoustic ducting
Good installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, helping create a smoother internal path for moving air.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction create additional resistance and can reduce the effective airflow delivered by the fan.
Where the duct needs to change direction, use gradual bends wherever possible. The supplied 5m length can be cut so that only the amount actually required is installed.
Installing 127mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 127mm / 5" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Support longer sections appropriately rather than allowing the entire weight of the ducting to hang directly from a fan, filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as dimensions can vary slightly between manufacturers.
127mm (5") x 5m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, controlled growing environments & compatible ventilation installations |
127mm (5") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 127mm, equivalent to 5 inches, and is supplied in a 5 metre length. Is this suitable for a 5-inch extraction fan?
Yes, provided the fan has a compatible nominal 127mm / 5" connection. Can it be used with a 5-inch carbon filter?
Yes. It can be used with compatible 127mm / 5" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 5m duct into shorter sections?
Yes. It can be cut to suit the required ventilation route or divided into several individual sections. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does duct length affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. Where should acoustic ducting be installed?
It can be used throughout a compatible ventilation route. Sections around the extraction fan can be particularly useful where transmitted fan noise is a concern. How should acoustic ducting be secured?
Use appropriately sized duct clamps or suitable ventilation fixings, with HVAC foil tape where additional sealing is required. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£10.50
Unit price per£10.50
Unit price per127mm (5") x 10m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation fans generate sound from both the fan itself and the movement of air through the system. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted sound.
This makes it particularly useful for indoor horticulture, propagation areas and controlled growing environments where ventilation equipment may operate for extended periods and reducing unnecessary noise is desirable.
Supplied in a generous 10 metre length with a nominal 127mm / 5" diameter, it can be connected to compatible fans, carbon filters and ventilation fittings. The flexible construction allows it to be routed around equipment and cut into the exact lengths required for the installation.
Why choose 127mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. Some of this sound can travel along ordinary flexible duct and become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct route.
It can be particularly useful around extraction fans, between compatible fans and carbon filters, and along longer sections of ventilation duct where transmitted noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Acoustic ducting for indoor horticulture
Reliable ventilation helps manage temperature, humidity and air exchange within controlled growing environments. Extraction and intake equipment can, however, become a significant source of noise when operating continuously or at higher fan speeds.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect ventilation equipment and route air around an installation.
The 127mm / 5" size is suitable for compatible ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
The 10m length is particularly useful for larger installations, longer ventilation routes or applications where several separate sections of acoustic ducting are required.
Getting the best airflow from acoustic ducting
Good installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, helping create a smoother internal path for moving air.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction create additional resistance and can reduce the effective airflow delivered by the fan.
Where the duct needs to change direction, use gradual bends wherever possible. Although this product provides 10 metres of ducting, there is no need to use the entire length in one continuous run.
Cutting each section to the length actually required can help minimise unnecessary resistance while leaving the remaining duct available for other parts of the ventilation installation.
Installing 127mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 127mm / 5" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Longer sections should be supported appropriately rather than allowing the entire weight of the ducting to hang directly from a fan, filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as dimensions can vary slightly between manufacturers.
127mm (5") x 10m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, controlled growing environments & compatible ventilation installations |
127mm (5") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 127mm, equivalent to 5 inches, and is supplied in a 10 metre length. Is this suitable for a 5-inch extraction fan?
Yes, provided the fan has a compatible nominal 127mm / 5" connection. Can it be used with a 5-inch carbon filter?
Yes. It can be used with compatible 127mm / 5" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 10m duct into shorter sections?
Yes. It can be cut to suit the required ventilation route or divided into several individual sections. Do I need to use the full 10 metre length?
No. Use only the amount required for the installation. Keeping duct routes reasonably short and direct generally helps minimise unnecessary airflow resistance. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does a longer duct run affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. How should a long run of acoustic ducting be supported?
Longer sections should be supported at suitable intervals so that their weight is not carried entirely by the fan, filter or connecting fittings. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£14.99
Unit price per£14.99
Unit price per317mm (12.5") x 5m Acoustic Ducting is a large-diameter insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through high-capacity extraction and intake systems.
Powerful ventilation systems generate sound from both the fan itself and the movement of large volumes of air. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted sound.
This makes it particularly useful for indoor horticulture, commercial growing areas and controlled growing environments where substantial ventilation equipment may operate for extended periods and controlling unnecessary noise is important.
Supplied in a 5 metre length with a nominal 317mm / 12.5" diameter, it can be connected to compatible high-capacity fans, carbon filters and ventilation fittings. The flexible construction allows the duct to be routed around equipment and cut to the required length during installation.
Why choose 317mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. With larger ventilation systems, substantial airflow can make transmitted sound particularly noticeable.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct route.
It can be particularly useful around high-capacity extraction fans, between compatible fans and carbon filters, and along sections of ductwork where transmitted ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Large-diameter acoustic ducting for indoor horticulture
Larger indoor horticultural environments can require substantial air movement to manage temperature, humidity and air exchange. High-capacity extraction and intake systems can consequently become a significant source of environmental-control noise.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect large ventilation components and route air through the installation.
The 317mm / 12.5" diameter is suitable for compatible high-capacity ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
Getting the best airflow from acoustic ducting
Correct installation is particularly important with large-diameter ventilation systems. Every length of duct, bend and fitting introduces resistance that the fan must overcome.
Flexible ducting should be extended sufficiently rather than left heavily compressed. This provides a smoother internal path for moving air and helps minimise unnecessary resistance and turbulence.
Keep the ventilation route as short and direct as practical. Avoid crushed sections and excessively tight bends, using gradual changes in direction wherever possible.
The supplied 5m length does not need to be used in full. Cutting the duct to the length actually required can help maintain an efficient airflow path.
Installing 317mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 317mm / 12.5" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Large-diameter insulated ducting can become bulky and relatively heavy over longer runs. Support the duct appropriately rather than allowing its full weight to hang directly from a fan, carbon filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as nominal sizes and connection dimensions can vary between manufacturers.
317mm (12.5") x 5m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable applications | Indoor horticulture, commercial growing areas, controlled growing environments & compatible ventilation installations |
317mm (12.5") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 317mm, equivalent to 12.5 inches, and is supplied in a 5 metre length. What is 317mm acoustic ducting typically used for?
Its large diameter makes it suitable for compatible high-capacity ventilation systems where substantial volumes of air need to be moved. Can it be used with a carbon filter?
Yes. It can be used with a carbon filter that has a compatible nominal 317mm / 12.5" connection. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 5m duct into shorter sections?
Yes. The duct can be cut to suit the required ventilation route or divided into several individual sections. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does duct length affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. Does large acoustic ducting need supporting?
Yes. Large-diameter insulated duct should be supported appropriately so its weight is not carried entirely by the fan, filter or connecting fittings. How should acoustic ducting be secured?
Use appropriately sized duct clamps or suitable ventilation fixings, with HVAC foil tape where additional sealing is required. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£23.95
Unit price per£23.95
Unit price per317mm (12.5") x 10m Acoustic Ducting is a large-diameter insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through high-capacity extraction and intake systems.
Powerful ventilation systems generate sound from both the fan itself and the movement of large volumes of air. Standard uninsulated ducting can allow this noise to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted sound.
This makes it particularly useful for indoor horticulture, commercial growing areas and controlled growing environments where substantial ventilation equipment may operate for extended periods and controlling unnecessary noise is important.
Supplied in a generous 10 metre length with a nominal 317mm / 12.5" diameter, it can be connected to compatible high-capacity fans, carbon filters and ventilation fittings. The flexible construction allows it to be routed around equipment and cut into the exact lengths required for the installation.
Why choose 317mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. With larger ventilation systems, substantial airflow can make transmitted sound particularly noticeable.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct route.
It can be particularly useful around high-capacity extraction fans, between compatible fans and carbon filters, and along longer sections of ductwork where transmitted ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Large-diameter acoustic ducting for indoor horticulture
Larger indoor horticultural environments can require substantial air movement to manage temperature, humidity and air exchange. High-capacity extraction and intake systems can consequently become a significant source of environmental-control noise.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect large ventilation components and route air through the installation.
The 317mm / 12.5" diameter is suitable for compatible high-capacity ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
The 10m length is particularly useful for larger growing areas, longer ventilation routes or installations requiring several separate sections of acoustic ducting.
Getting the best airflow from acoustic ducting
Correct installation is particularly important with large-diameter ventilation systems. Every length of duct, bend and fitting introduces resistance that the fan must overcome.
Flexible ducting should be extended sufficiently rather than left heavily compressed. This provides a smoother internal path for moving air and helps minimise unnecessary resistance and turbulence.
Keep the ventilation route as short and direct as practical. Avoid crushed sections and excessively tight bends, using gradual changes in direction wherever possible.
Although 10 metres of ducting is supplied, there is no requirement to use the complete length in one continuous run. Cutting each section to the length actually required can help minimise unnecessary airflow resistance.
Installing 317mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 317mm / 12.5" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Large-diameter insulated ducting can become bulky and relatively heavy over longer runs. Support the duct appropriately rather than allowing its full weight to hang directly from a fan, carbon filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as nominal sizes and connection dimensions can vary between manufacturers.
317mm (12.5") x 10m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable applications | Indoor horticulture, commercial growing areas, controlled growing environments & compatible ventilation installations |
317mm (12.5") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 317mm, equivalent to 12.5 inches, and is supplied in a 10 metre length. What is 317mm acoustic ducting typically used for?
Its large diameter makes it suitable for compatible high-capacity ventilation systems where substantial volumes of air need to be moved. Can it be used with a carbon filter?
Yes. It can be used with a carbon filter that has a compatible nominal 317mm / 12.5" connection. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 10m duct into shorter sections?
Yes. It can be cut to suit the required ventilation route or divided into several individual sections. Do I need to use the full 10 metre length?
No. Use only the amount required for the installation. Keeping duct routes reasonably short and direct generally helps minimise unnecessary airflow resistance. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does a longer duct run affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. Does large acoustic ducting need supporting?
Yes. Large-diameter insulated duct should be supported appropriately so its weight is not carried entirely by the fan, filter or connecting fittings. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£12.99
Unit price per£12.99
Unit price per254mm (10") x 5m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Powerful ventilation equipment can generate noise from both the fan itself and the movement of air through the system. Standard uninsulated ducting can allow this sound to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted noise.
This makes it particularly useful for indoor horticulture, propagation areas, commercial growing areas and controlled growing environments where ventilation equipment may operate for extended periods.
Supplied in a 5 metre length with a nominal 254mm / 10" diameter, it can be connected to compatible fans, carbon filters and ventilation fittings. Its flexible construction allows the duct to be routed around equipment and cut to the required length during installation.
Why choose 254mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. Some of this sound can travel along ordinary flexible duct and become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the ventilation route.
It can be particularly useful around extraction fans, between compatible fans and carbon filters, and along sections of ductwork where transmitted ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Acoustic ducting for controlled growing environments
Effective ventilation is important for managing temperature, humidity and air exchange within indoor growing environments. Higher-capacity extraction and intake equipment can, however, become a significant source of environmental-control noise.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect ventilation equipment and route air through the installation.
The 254mm / 10" size is suitable for compatible higher-capacity ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
Getting the best airflow from acoustic ducting
Correct duct installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, helping create a smoother internal path for moving air.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction create additional resistance and can reduce the effective airflow delivered by the fan.
Where the duct needs to change direction, use gradual bends wherever possible. The supplied 5m length can be cut so that only the amount actually required is installed.
Installing 254mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 254mm / 10" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Larger insulated ducting should be supported appropriately rather than allowing its full weight to hang directly from a fan, carbon filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as nominal sizes and connection dimensions can vary between manufacturers.
254mm (10") x 5m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, commercial growing areas, controlled growing environments & compatible ventilation installations |
254mm (10") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 5 metre length. Is this suitable for a 10-inch extraction fan?
Yes, provided the fan has a compatible nominal 254mm / 10" duct connection. Can it be used with a 10-inch carbon filter?
Yes. It can be used with compatible 254mm / 10" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 5m duct into shorter sections?
Yes. It can be cut to suit the required ventilation route or divided into several individual sections. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does duct length affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. Does larger acoustic ducting need supporting?
Yes. Larger insulated duct should be supported appropriately so its weight is not carried entirely by the fan, filter or connecting fittings. How should acoustic ducting be secured?
Use appropriately sized duct clamps or suitable ventilation fixings, with HVAC foil tape where additional sealing is required. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£17.50
Unit price per£17.50
Unit price per254mm (10") x 10m Acoustic Ducting is an insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through high-capacity extraction and intake systems.
Powerful ventilation equipment can generate noise from both the fan itself and the movement of air through the system. Standard uninsulated ducting can allow this sound to travel along the ventilation route, while acoustic ducting incorporates an insulating layer around the inner duct to help absorb transmitted noise.
This makes it particularly useful for indoor horticulture, propagation areas, commercial growing areas and controlled growing environments where ventilation equipment may operate for extended periods and controlling unnecessary noise is important.
Supplied in a generous 10 metre length with a nominal 254mm / 10" diameter, it can be connected to compatible fans, carbon filters and ventilation fittings. Its flexible construction allows the duct to be routed around equipment and cut into the exact lengths required for the installation.
Why choose 254mm acoustic ducting?
How does acoustic ducting reduce noise?
Noise within a ventilation system can come from the fan motor, vibration and turbulent air moving through the ductwork. Some of this sound can travel along ordinary flexible duct and become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner airflow passage with insulation designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the ventilation route.
It can be particularly useful around extraction fans, between compatible fans and carbon filters, and along longer sections of ductwork where transmitted ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make a ventilation system completely silent. Fan design, fan speed, airflow velocity, vibration and installation quality all contribute to the final noise level.
Acoustic ducting for controlled growing environments
Effective ventilation is important for managing temperature, humidity and air exchange within indoor growing environments. Higher-capacity extraction and intake equipment can, however, become a significant source of environmental-control noise.
Acoustic ducting provides a practical way to reduce sound transmission while maintaining the flexibility needed to connect ventilation equipment and route air through the installation.
The 254mm / 10" size is suitable for compatible higher-capacity ventilation systems using appropriately sized inline fans, carbon filters, connectors and other round duct fittings.
The 10m length is particularly useful for larger growing areas, longer ventilation routes or installations requiring several separate sections of acoustic ducting.
Getting the best airflow from acoustic ducting
Correct duct installation is important for maintaining ventilation performance. Flexible ducting should be extended sufficiently rather than left heavily compressed, helping create a smoother internal path for moving air.
Keep the duct route as short and direct as practical. Tight bends, crushed sections and unnecessary changes in direction create additional resistance and can reduce the effective airflow delivered by the fan.
Where the duct needs to change direction, use gradual bends wherever possible. Although this product provides 10 metres of ducting, there is no need to use the entire length in one continuous run.
Cutting each section to the length actually required can help minimise unnecessary airflow resistance while leaving the remaining duct available for other parts of the ventilation installation.
Installing 254mm acoustic ducting
Before installation, check that the fan, carbon filter and other ventilation components have compatible nominal 254mm / 10" connections.
Fit the flexible inner duct securely over the ventilation connection and fasten it using a suitably sized duct clamp or appropriate fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the surrounding insulation and outer covering neatly around the completed connection so that the acoustic layer remains as continuous as practical.
Larger insulated ducting should be supported appropriately rather than allowing its full weight to hang directly from a fan, carbon filter or connecting fitting.
Compatible ventilation equipment
Check the actual connection diameter of individual ventilation components before installation, as nominal sizes and connection dimensions can vary between manufacturers.
254mm (10") x 10m Acoustic Ducting product details
| Product type | Insulated acoustic flexible ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Acoustically insulated flexible ventilation duct |
| Primary purpose | Air movement with reduced transmission of ventilation noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Indoor horticulture, propagation areas, commercial growing areas, controlled growing environments & compatible ventilation installations |
254mm (10") Acoustic Ducting FAQs
What is acoustic ducting?
Acoustic ducting is insulated flexible ventilation duct designed to help absorb and reduce sound transmitted through an extraction or intake system. What size is this acoustic duct?
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 10 metre length. Is this suitable for a 10-inch extraction fan?
Yes, provided the fan has a compatible nominal 254mm / 10" duct connection. Can it be used with a 10-inch carbon filter?
Yes. It can be used with compatible 254mm / 10" carbon filters and extraction fans as part of an appropriately sized ventilation system. Does acoustic ducting reduce fan noise?
It helps reduce fan and airflow sound transmitted along the ductwork. It does not completely eliminate noise generated directly by the fan. Is acoustic ducting quieter than ordinary flexible ducting?
Its insulating layer is specifically intended to absorb transmitted sound, making it useful where reducing ventilation noise is important. Can acoustic ducting be used for horticultural extraction?
Yes. It is well suited to indoor horticultural ventilation systems where temperature, humidity and air exchange need to be managed while keeping transmitted ventilation noise under control. Can it be used for air intake?
Yes. Acoustic ducting can be incorporated into compatible intake as well as extraction systems. Can I cut the 10m duct into shorter sections?
Yes. It can be cut to suit the required ventilation route or divided into several individual sections. Do I need to use the full 10 metre length?
No. Use only the amount required for the installation. Keeping duct routes reasonably short and direct generally helps minimise unnecessary airflow resistance. Should flexible acoustic ducting be fully extended?
It should be extended sufficiently for the installation rather than left unnecessarily compressed. This helps create a smoother internal path for airflow. Do bends in acoustic ducting affect airflow?
Yes. Tight bends increase resistance and turbulence, so smooth and gradual changes in direction are preferable wherever possible. Does a longer duct run affect extraction performance?
Every length of duct introduces some resistance. Longer runs, multiple bends and additional fittings can therefore reduce the effective airflow of a ventilation system. How should a long run of acoustic ducting be supported?
Longer sections should be supported at suitable intervals so that their weight is not carried entirely by the fan, filter or connecting fittings. How can horticultural ventilation noise be reduced further?
Correct fan sizing, sensible duct routing, vibration isolation, suitable fan-speed control and ventilation silencers can be combined with acoustic ducting to create a quieter overall system.
£0.49
Unit price per£0.49
Unit price per200mm (8") Quick Release Ducting Clip provides a strong, secure and removable connection for compatible 200mm round ventilation ducting, fans, filters and fittings.
A secure duct connection is important for maintaining an efficient ventilation system. Loose connections can allow ducting to move, create unwanted air leakage and make servicing more difficult. This adjustable metal clip fits around the outside of the duct and tightens securely around the connection point.
The quick-release design is particularly useful where ventilation equipment may need to be disconnected for cleaning, maintenance or replacement. Rather than permanently fixing the ductwork, the clip can be released and refitted when access is required.
Sized for 200mm / 8" ventilation systems, it is suitable for connecting compatible flexible ducting and acoustic ducting to fans, carbon filters, rigid fittings and other round ventilation components.
Why choose a quick release ducting clip?
Secure 200mm ventilation connections
Quick release ducting clips are designed to create a reliable mechanical connection between flexible ducting and round ventilation equipment.
They are particularly useful in indoor horticultural ventilation systems where fans, filters and ductwork may need periodic inspection, cleaning or replacement.
The clip can be used around the flexible inner section of acoustic ducting or around compatible standard flexible ducting, securing it to an appropriately sized spigot or connector.
How to fit a quick release ducting clip
Position the ducting over the compatible 200mm connection and place the clip around the outside of the duct. Make sure sufficient ducting overlaps the connection before tightening the clip.
Tighten the band until the duct is held securely. The connection should be firm without unnecessarily crushing or damaging the ducting.
Where a particularly airtight connection is required, suitable HVAC foil tape can also be used in conjunction with the mechanical fixing.
When equipment needs to be removed, release the clip, disconnect the duct and refit the clip when the system is reassembled.
What can a 200mm ducting clip be used with?
Always check the actual outside diameter of the connection and the required clamping range before installation, particularly when combining components from different manufacturers.
200mm (8") Quick Release Ducting Clip product details
| Product type | Quick release ventilation ducting clip |
|---|---|
| Nominal size | 200mm / 8" |
| Construction | Metal band clamp |
| Fastening type | Adjustable quick-release fastening |
| Primary purpose | Securing ducting to compatible round ventilation connections |
| Suitable ducting | Compatible flexible & acoustic ventilation ducting |
| Suitable equipment | Fans, carbon filters, connectors & compatible round ventilation fittings |
| Outer case quantity | 100 clips |
200mm (8") Quick Release Ducting Clip FAQs
What is a quick release ducting clip?
It is an adjustable metal band clamp used to secure flexible ducting around a compatible round ventilation connection. What size ventilation system is this clip for?
This version is intended for compatible nominal 200mm / 8" ventilation connections. Can I use this with flexible ducting?
Yes. It is designed for securing compatible flexible ventilation ducting to round fans, filters, connectors and fittings. Can it be used with acoustic ducting?
Yes. It can be used to secure the flexible duct section of compatible 200mm acoustic ducting to an appropriately sized connection. Can I use it to connect ducting to an extraction fan?
Yes, provided the fan connection and ducting are compatible with the clip's 200mm nominal size. Can it secure ducting to a carbon filter?
Yes. It is suitable for compatible 200mm carbon filter connections. Why use a ducting clip instead of tape?
A ducting clip provides a mechanical fixing around the connection and can be released when equipment needs servicing. Foil tape can still be added where additional air sealing is required. Is the ducting clip reusable?
Yes. The quick-release fastening allows the clip to be opened and refitted when ventilation components need to be disconnected. How tight should the clip be?
It should be tightened sufficiently to hold the duct securely without unnecessarily crushing or damaging the ducting or connection. Does a ducting clip help prevent air leaks?
A secure mechanical connection helps keep ducting firmly seated on the fitting. Where additional sealing is required, suitable HVAC foil tape can be used alongside the clip. Can it be used on intake and extraction systems?
Yes. The clip can be used on compatible duct connections in both intake and extraction ventilation systems. Is this suitable for horticultural ventilation systems?
Yes. It is suitable for compatible ventilation installations used in propagation areas, indoor growing areas and other controlled horticultural environments. Can it connect two pieces of ducting directly together?
A suitable duct connector or coupler is normally placed between the two duct sections, with a separate clip securing the duct at each end. Should I check the connection diameter before ordering?
Yes. Check the nominal and actual connection dimensions of your fan, filter or fitting, particularly when combining ventilation equipment from different manufacturers.
£0.38
Unit price per£0.38
Unit price per125mm (5") Quick Release Ducting Clip provides a strong, secure and removable connection for compatible 125mm round ventilation ducting, fans, filters and fittings.
A secure duct connection is important for maintaining an efficient ventilation system. Loose connections can allow ducting to move and create unwanted air leakage. This adjustable metal clip fits around the outside of the duct and tightens securely around the connection point.
The quick-release design is particularly useful where ventilation equipment may need to be disconnected for cleaning, maintenance or replacement. The clip can be released and refitted, providing a practical alternative to relying solely on tape for mechanical fixing.
Sized for 125mm / 5" ventilation systems, it is suitable for connecting compatible flexible ducting and acoustic ducting to fans, carbon filters, rigid fittings and other round ventilation components.
Why choose a quick release ducting clip?
Secure 125mm ventilation connections
Quick release ducting clips are designed to create a reliable mechanical connection between flexible ducting and round ventilation equipment.
They are particularly useful in indoor horticultural ventilation systems where fans, filters and ductwork may need periodic inspection, cleaning or replacement.
The clip can be used around compatible standard flexible ducting or the flexible inner section of acoustic ducting, securing it to an appropriately sized spigot or connector.
How to fit a 125mm quick release ducting clip
Position the ducting over the compatible 125mm connection and place the clip around the outside of the duct. Make sure sufficient ducting overlaps the connection before tightening the clip.
Tighten the band until the duct is held securely. The connection should be firm without unnecessarily crushing or damaging the ducting.
Where a particularly airtight connection is required, suitable HVAC foil tape can also be used in conjunction with the mechanical fixing.
When equipment needs to be removed for cleaning or maintenance, release the clip, disconnect the duct and refit the clip when the system is reassembled.
What can a 125mm ducting clip be used with?
Always check the actual outside diameter of the connection and the required clamping range before installation, particularly when combining components from different manufacturers.
125mm (5") Quick Release Ducting Clip product details
| Product type | Quick release ventilation ducting clip |
|---|---|
| Nominal size | 125mm / 5" |
| Construction | Metal band clamp |
| Fastening type | Adjustable quick-release fastening |
| Primary purpose | Securing ducting to compatible round ventilation connections |
| Suitable ducting | Compatible flexible & acoustic ventilation ducting |
| Suitable equipment | Fans, carbon filters, connectors & compatible round ventilation fittings |
| Outer case quantity | 100 clips |
125mm (5") Quick Release Ducting Clip FAQs
What is a quick release ducting clip?
It is an adjustable metal band clamp used to secure flexible ducting around a compatible round ventilation connection. What size ventilation system is this clip for?
This version is intended for compatible nominal 125mm / 5" ventilation connections. Can I use this with flexible ducting?
Yes. It is designed for securing compatible flexible ventilation ducting to round fans, filters, connectors and fittings. Can it be used with acoustic ducting?
Yes. It can be used to secure the flexible duct section of compatible 125mm acoustic ducting to an appropriately sized connection. Can I use it to connect ducting to an extraction fan?
Yes, provided the fan connection and ducting are compatible with the clip's 125mm nominal size. Can it secure ducting to a carbon filter?
Yes. It is suitable for compatible 125mm carbon filter connections. Why use a ducting clip instead of tape?
A ducting clip provides a mechanical fixing around the connection and can be released when equipment needs servicing. Foil tape can still be added where additional air sealing is required. Is the ducting clip reusable?
Yes. The quick-release fastening allows the clip to be opened and refitted when ventilation components need to be disconnected. How tight should the clip be?
It should be tightened sufficiently to hold the duct securely without unnecessarily crushing or damaging the ducting or connection. Does a ducting clip help prevent air leaks?
A secure mechanical connection helps keep ducting firmly seated on the fitting. Where additional sealing is required, suitable HVAC foil tape can be used alongside the clip. Can it be used on intake and extraction systems?
Yes. The clip can be used on compatible duct connections in both intake and extraction ventilation systems. Is this suitable for horticultural ventilation systems?
Yes. It is suitable for compatible ventilation installations used in propagation areas, indoor growing areas and other controlled horticultural environments. Can it connect two pieces of ducting directly together?
A suitable duct connector or coupler is normally placed between the two duct sections, with a separate clip securing the duct at each end. Should I check the connection diameter before ordering?
Yes. Check the nominal and actual connection dimensions of your fan, filter or fitting, particularly when combining ventilation equipment from different manufacturers.
£0.35
Unit price per£0.35
Unit price per100mm (4") Quick Release Ducting Clip provides a strong, secure and removable connection for compatible 100mm round ventilation ducting, fans, filters and fittings.
A secure duct connection is important for maintaining an efficient ventilation system. Loose connections can allow ducting to move and create unwanted air leakage. This adjustable metal clip fits around the outside of the duct and tightens securely around the connection point.
The quick-release design is particularly useful where ventilation equipment may need to be disconnected for cleaning, maintenance or replacement. The clip can be released and refitted, providing a practical alternative to relying solely on tape for mechanical fixing.
Sized for 100mm / 4" ventilation systems, it is suitable for connecting compatible flexible ducting and acoustic ducting to fans, carbon filters, rigid fittings and other round ventilation components.
Why choose a quick release ducting clip?
Secure 100mm ventilation connections
Quick release ducting clips are designed to create a reliable mechanical connection between flexible ducting and round ventilation equipment.
They are particularly useful in indoor horticultural ventilation systems where fans, filters and ductwork may need periodic inspection, cleaning or replacement.
The clip can be used around compatible standard flexible ducting or the flexible inner section of acoustic ducting, securing it to an appropriately sized spigot or connector.
How to fit a 100mm quick release ducting clip
Position the ducting over the compatible 100mm connection and place the clip around the outside of the duct. Make sure sufficient ducting overlaps the connection before tightening the clip.
Tighten the band until the duct is held securely. The connection should be firm without unnecessarily crushing or damaging the ducting.
Where a particularly airtight connection is required, suitable HVAC foil tape can also be used in conjunction with the mechanical fixing.
When equipment needs to be removed for cleaning or maintenance, release the clip, disconnect the duct and refit the clip when the system is reassembled.
What can a 100mm ducting clip be used with?
Always check the actual outside diameter of the connection and the required clamping range before installation, particularly when combining components from different manufacturers.
100mm (4") Quick Release Ducting Clip product details
| Product type | Quick release ventilation ducting clip |
|---|---|
| Nominal size | 100mm / 4" |
| Construction | Metal band clamp |
| Fastening type | Adjustable quick-release fastening |
| Primary purpose | Securing ducting to compatible round ventilation connections |
| Suitable ducting | Compatible flexible & acoustic ventilation ducting |
| Suitable equipment | Fans, carbon filters, connectors & compatible round ventilation fittings |
| Outer case quantity | 100 clips |
100mm (4") Quick Release Ducting Clip FAQs
What is a quick release ducting clip?
It is an adjustable metal band clamp used to secure flexible ducting around a compatible round ventilation connection. What size ventilation system is this clip for?
This version is intended for compatible nominal 100mm / 4" ventilation connections. Can I use this with flexible ducting?
Yes. It is designed for securing compatible flexible ventilation ducting to round fans, filters, connectors and fittings. Can it be used with acoustic ducting?
Yes. It can be used to secure the flexible duct section of compatible 100mm acoustic ducting to an appropriately sized connection. Can I use it to connect ducting to an extraction fan?
Yes, provided the fan connection and ducting are compatible with the clip's 100mm nominal size. Can it secure ducting to a carbon filter?
Yes. It is suitable for compatible 100mm carbon filter connections. Why use a ducting clip instead of tape?
A ducting clip provides a mechanical fixing around the connection and can be released when equipment needs servicing. Foil tape can still be added where additional air sealing is required. Is the ducting clip reusable?
Yes. The quick-release fastening allows the clip to be opened and refitted when ventilation components need to be disconnected. How tight should the clip be?
It should be tightened sufficiently to hold the duct securely without unnecessarily crushing or damaging the ducting or connection. Does a ducting clip help prevent air leaks?
A secure mechanical connection helps keep ducting firmly seated on the fitting. Where additional sealing is required, suitable HVAC foil tape can be used alongside the clip. Can it be used on intake and extraction systems?
Yes. The clip can be used on compatible duct connections in both intake and extraction ventilation systems. Is this suitable for horticultural ventilation systems?
Yes. It is suitable for compatible ventilation installations used in propagation areas, indoor growing areas and other controlled horticultural environments. Can it connect two pieces of ducting directly together?
A suitable duct connector or coupler is normally placed between the two duct sections, with a separate clip securing the duct at each end. Should I check the connection diameter before ordering?
Yes. Check the nominal and actual connection dimensions of your fan, filter or fitting, particularly when combining ventilation equipment from different manufacturers.
£0.99
Unit price per£0.99
Unit price per315mm (12.5") Quick Release Ducting Clip provides a strong, secure and removable connection for compatible 315mm round ventilation ducting, fans, filters and fittings.
A secure duct connection is important for maintaining an efficient ventilation system. Loose connections can allow ducting to move and create unwanted air leakage. This adjustable metal clip fits around the outside of the duct and tightens securely around the connection point.
The quick-release design is particularly useful where ventilation equipment may need to be disconnected for cleaning, maintenance or replacement. The clip can be released and refitted, providing a practical alternative to relying solely on tape for mechanical fixing.
Sized for 315mm / 12.5" ventilation systems, it is suitable for connecting compatible flexible ducting and acoustic ducting to fans, carbon filters, rigid fittings and other round ventilation components.
Why choose a quick release ducting clip?
Secure 315mm ventilation connections
Quick release ducting clips are designed to create a reliable mechanical connection between flexible ducting and round ventilation equipment.
They are particularly useful in indoor horticultural ventilation systems where fans, filters and ductwork may need periodic inspection, cleaning or replacement.
The 315mm size is suited to larger ventilation installations where high-capacity fans and filters require substantial duct connections. The clip can be used around compatible standard flexible ducting or the flexible inner section of acoustic ducting.
How to fit a 315mm quick release ducting clip
Position the ducting over the compatible 315mm connection and place the clip around the outside of the duct. Make sure sufficient ducting overlaps the connection before tightening the clip.
Tighten the band until the duct is held securely. The connection should be firm without unnecessarily crushing or damaging the ducting.
Where a particularly airtight connection is required, suitable HVAC foil tape can also be used in conjunction with the mechanical fixing.
When equipment needs to be removed for cleaning or maintenance, release the clip, disconnect the duct and refit the clip when the system is reassembled.
What can a 315mm ducting clip be used with?
Always check the actual outside diameter of the connection and the required clamping range before installation, particularly when combining components from different manufacturers.
315mm (12.5") Quick Release Ducting Clip product details
| Product type | Quick release ventilation ducting clip |
|---|---|
| Nominal size | 315mm / 12.5" |
| Construction | Metal band clamp |
| Fastening type | Adjustable quick-release fastening |
| Primary purpose | Securing ducting to compatible round ventilation connections |
| Suitable ducting | Compatible flexible & acoustic ventilation ducting |
| Suitable equipment | Fans, carbon filters, connectors & compatible round ventilation fittings |
| Outer case quantity | 100 clips |
315mm (12.5") Quick Release Ducting Clip FAQs
What is a quick release ducting clip?
It is an adjustable metal band clamp used to secure flexible ducting around a compatible round ventilation connection. What size ventilation system is this clip for?
This version is intended for compatible nominal 315mm / 12.5" ventilation connections. Can I use this with flexible ducting?
Yes. It is designed for securing compatible flexible ventilation ducting to round fans, filters, connectors and fittings. Can it be used with acoustic ducting?
Yes. It can be used to secure the flexible duct section of compatible 315mm acoustic ducting to an appropriately sized connection. Can I use it to connect ducting to an extraction fan?
Yes, provided the fan connection and ducting are compatible with the clip's 315mm nominal size. Can it secure ducting to a carbon filter?
Yes. It is suitable for compatible 315mm carbon filter connections. Why use a ducting clip instead of tape?
A ducting clip provides a mechanical fixing around the connection and can be released when equipment needs servicing. Foil tape can still be added where additional air sealing is required. Is the ducting clip reusable?
Yes. The quick-release fastening allows the clip to be opened and refitted when ventilation components need to be disconnected. How tight should the clip be?
It should be tightened sufficiently to hold the duct securely without unnecessarily crushing or damaging the ducting or connection. Does a ducting clip help prevent air leaks?
A secure mechanical connection helps keep ducting firmly seated on the fitting. Where additional sealing is required, suitable HVAC foil tape can be used alongside the clip. Can it be used on intake and extraction systems?
Yes. The clip can be used on compatible duct connections in both intake and extraction ventilation systems. Is this suitable for horticultural ventilation systems?
Yes. It is suitable for compatible ventilation installations used in propagation areas, indoor growing areas and other controlled horticultural environments. Can it connect two pieces of ducting directly together?
A suitable duct connector or coupler is normally placed between the two duct sections, with a separate clip securing the duct at each end. Should I check the connection diameter before ordering?
Yes. Check the nominal and actual connection dimensions of your fan, filter or fitting, particularly when combining ventilation equipment from different manufacturers.
£0.89
Unit price per£0.89
Unit price per250mm (10") Quick Release Ducting Clip provides a strong, secure and removable connection for compatible 250mm round ventilation ducting, fans, filters and fittings.
A secure duct connection is important for maintaining an efficient ventilation system. Loose connections can allow ducting to move and create unwanted air leakage. This adjustable metal clip fits around the outside of the duct and tightens securely around the connection point.
The quick-release design is particularly useful where ventilation equipment may need to be disconnected for cleaning, maintenance or replacement. The clip can be released and refitted, providing a practical alternative to relying solely on tape for mechanical fixing.
Sized for 250mm / 10" ventilation systems, it is suitable for connecting compatible flexible ducting and acoustic ducting to fans, carbon filters, rigid fittings and other round ventilation components.
Why choose a quick release ducting clip?
Secure 250mm ventilation connections
Quick release ducting clips are designed to create a reliable mechanical connection between flexible ducting and round ventilation equipment.
They are particularly useful in controlled environment and horticultural ventilation systems where fans, filters and ductwork may need periodic inspection, cleaning or replacement.
The 250mm size is suitable for larger ventilation installations using compatible 10-inch fans, filters and ductwork. The clip can be used around standard flexible ducting or the flexible inner section of compatible acoustic ducting.
How to fit a 250mm quick release ducting clip
Position the ducting over the compatible 250mm connection and place the clip around the outside of the duct. Make sure sufficient ducting overlaps the connection before tightening the clip.
Tighten the band until the duct is held securely. The connection should be firm without unnecessarily crushing or damaging the ducting.
Where additional air sealing is required, suitable HVAC foil tape can also be used alongside the mechanical fixing.
When equipment needs to be removed for cleaning or maintenance, release the clip, disconnect the duct and refit the clip when the system is reassembled.
What can a 250mm ducting clip be used with?
Always check the actual outside diameter of the connection and the required clamping range before installation, particularly when combining components from different manufacturers.
250mm (10") Quick Release Ducting Clip product details
| Product type | Quick release ventilation ducting clip |
|---|---|
| Nominal size | 250mm / 10" |
| Construction | Metal band clamp |
| Fastening type | Adjustable quick-release fastening |
| Primary purpose | Securing ducting to compatible round ventilation connections |
| Suitable ducting | Compatible flexible & acoustic ventilation ducting |
| Suitable equipment | Fans, carbon filters, connectors & compatible round ventilation fittings |
| Outer case quantity | 100 clips |
250mm (10") Quick Release Ducting Clip FAQs
What is a quick release ducting clip?
It is an adjustable metal band clamp used to secure flexible ducting around a compatible round ventilation connection. What size ventilation system is this clip for?
This version is intended for compatible nominal 250mm / 10" ventilation connections. Can I use this with flexible ducting?
Yes. It is designed for securing compatible flexible ventilation ducting to round fans, filters, connectors and fittings. Can it be used with acoustic ducting?
Yes. It can be used to secure the flexible duct section of compatible 250mm acoustic ducting to an appropriately sized connection. Can I use it to connect ducting to an extraction fan?
Yes, provided the fan connection and ducting are compatible with the clip's 250mm nominal size. Can it secure ducting to a carbon filter?
Yes. It is suitable for compatible 250mm carbon filter connections. Why use a ducting clip instead of tape?
A ducting clip provides a mechanical fixing around the connection and can be released when equipment needs servicing. Foil tape can still be added where additional air sealing is required. Is the ducting clip reusable?
Yes. The quick-release fastening allows the clip to be opened and refitted when ventilation components need to be disconnected. How tight should the clip be?
It should be tightened sufficiently to hold the duct securely without unnecessarily crushing or damaging the ducting or connection. Does a ducting clip help prevent air leaks?
A secure mechanical connection helps keep ducting firmly seated on the fitting. Where additional sealing is required, suitable HVAC foil tape can be used alongside the clip. Can it be used on intake and extraction systems?
Yes. The clip can be used on compatible duct connections in both intake and extraction ventilation systems. Is this suitable for horticultural ventilation systems?
Yes. It can be used as part of compatible ventilation systems in propagation areas, indoor growing areas and other controlled horticultural environments. Can it connect two pieces of ducting directly together?
A suitable duct connector or coupler is normally placed between the two duct sections, with a separate clip securing the duct at each end. Should I check the connection diameter before ordering?
Yes. Check the nominal and actual connection dimensions of your fan, filter or fitting, particularly when combining ventilation equipment from different manufacturers.
£4.29
Unit price per£4.29
Unit price per127mm (5") x 5m COMBI Ducting is a flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length, making it a practical choice for both new ventilation installations and replacement duct runs.
With a nominal diameter of 127mm / 5", this 5 metre length is designed for use with compatible fans, filters, connectors, reducers and other round ventilation components.
Why choose COMBI ducting?
Flexible ducting for controlled environment ventilation
Effective ventilation depends on moving air between components with as little unnecessary resistance as practical. Flexible COMBI ducting makes it easier to create a complete duct route without requiring rigid sections throughout the installation.
It is suitable for connecting compatible extraction fans, air filters and ventilation fittings in propagation areas, growing areas, nurseries and other controlled horticultural environments.
The duct can also be used for general ventilation applications where a flexible 127mm air duct is required.
Installing 127mm COMBI ducting
Extend the ducting to the required length and plan the route before making the final connections. Keeping the duct run reasonably direct helps reduce unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct, as restrictions in the airflow path can reduce ventilation performance.
Fit the duct securely over compatible 127mm connections and use an appropriately sized ducting clip or clamp to create a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Longer runs should be supported where necessary rather than allowing excessive sections of ducting to hang unsupported.
Getting the best airflow from flexible ducting
Flexible ducting provides considerable installation freedom, but the route of the duct still affects the performance of the ventilation system.
For efficient airflow, use the shortest practical duct route, minimise unnecessary bends and avoid leaving excessive compressed duct between components. Where a direction change is required, a gradual bend is preferable to a tightly folded section.
Fan performance should always be considered across the complete ventilation system, including the duct length, bends, filters, silencers, reducers and other fittings installed in the airflow path.
127mm (5") x 5m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 5m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
127mm (5") x 5m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical and robust way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 127mm, commonly referred to as 5-inch ducting. How long is the ducting?
This product is supplied as a 5 metre length. Can COMBI ducting be used with a 5-inch extraction fan?
Yes, it can be used with compatible fans designed for nominal 127mm / 5" ventilation connections. Can it connect to a carbon filter?
Yes. The ducting can be connected to a compatible 127mm carbon filter or to suitable adapters where different component sizes are being combined. Can COMBI ducting be used for air intake?
Yes. It can be used for both extraction and intake applications within a compatible ventilation system. Can I cut the 5m duct to a shorter length?
Yes. Flexible ducting can be cut to suit the installation, allowing the 5 metre length to be divided or shortened as required. Do I need to use the full 5 metres?
No. Use only the length required. Keeping duct runs as short and direct as practical generally helps minimise resistance to airflow. How should COMBI ducting be attached?
Fit the duct over a compatible connection and secure it with an appropriately sized ducting clip or clamp. HVAC foil tape can be added where further air sealing is required. Can the ducting bend around obstacles?
Yes. Its flexible construction allows it to be routed around equipment and obstacles, although gradual bends are preferable to tight folds or sharp restrictions. Do bends in flexible ducting reduce airflow?
Every duct system creates some resistance. Excessive duct length, tight bends and compressed sections can increase that resistance, so a direct and unrestricted route is preferable. Can this ducting be used with reducers and connectors?
Yes. Compatible round connectors, reducers, elbows and other ventilation fittings can be incorporated into the duct system as required. Should long sections of flexible ducting be supported?
Yes. Supporting longer sections can help prevent excessive sagging and keep the intended airflow route in place. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce the transmission of fan and airflow noise. Is this suitable for horticultural ventilation?
Yes. It is suitable for compatible ventilation systems used in propagation, nursery and controlled growing environments, as well as general ventilation applications.
£7.99
Unit price per£7.99
Unit price per127mm (5") x 10m COMBI Ducting is a flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length. The generous 10 metre length is particularly useful for longer ventilation runs or where several shorter sections are required from one length.
With a nominal diameter of 127mm / 5", it is designed for use with compatible fans, filters, connectors, reducers and other round ventilation components.
Why choose COMBI ducting?
Flexible ducting for controlled environment ventilation
Effective ventilation depends on moving air between components with as little unnecessary resistance as practical. Flexible COMBI ducting makes it easier to create a complete duct route without requiring rigid sections throughout the installation.
It is suitable for connecting compatible extraction fans, air filters and ventilation fittings in propagation areas, growing areas, nurseries and other controlled horticultural environments.
The 10 metre length also provides useful flexibility on larger installations where equipment is positioned further apart or where multiple sections of 127mm ducting are required.
Installing 127mm COMBI ducting
Extend the ducting to the required length and plan the route before making the final connections. Keeping the duct run reasonably direct helps reduce unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct, as restrictions in the airflow path can reduce ventilation performance.
Fit the duct securely over compatible 127mm connections and use an appropriately sized ducting clip or clamp to create a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Longer duct runs should be supported where necessary rather than allowing excessive sections to sag or hang unsupported.
Getting the best airflow from flexible ducting
Although this product is supplied as a 10 metre length, there is no requirement to use the entire length in a single duct run. Using only the amount required for the installation can help reduce unnecessary resistance.
For efficient airflow, use the shortest practical route, minimise unnecessary bends and avoid leaving excessive compressed duct between components. Where a direction change is required, a gradual bend is preferable to a tightly folded section.
Fan performance should be considered across the complete ventilation system, including duct length, bends, filters, silencers, reducers and other fittings installed in the airflow path.
127mm (5") x 10m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 10m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
127mm (5") x 10m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical and robust way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 127mm, commonly referred to as 5-inch ducting. How long is the ducting?
This product is supplied as a 10 metre length. Can COMBI ducting be used with a 5-inch extraction fan?
Yes, it can be used with compatible fans designed for nominal 127mm / 5" ventilation connections. Can it connect to a carbon filter?
Yes. The ducting can be connected to a compatible 127mm carbon filter or to suitable adapters where different component sizes are being combined. Can COMBI ducting be used for air intake?
Yes. It can be used for both extraction and intake applications within a compatible ventilation system. Can I cut the 10m duct to shorter lengths?
Yes. Flexible ducting can be cut to suit the installation, making the 10 metre length useful where several shorter sections are required. Do I need to use the full 10 metres?
No. Use only the length required. Keeping duct runs as short and direct as practical generally helps minimise resistance to airflow. How should COMBI ducting be attached?
Fit the duct over a compatible connection and secure it with an appropriately sized ducting clip or clamp. HVAC foil tape can be added where further air sealing is required. Can the ducting bend around obstacles?
Yes. Its flexible construction allows it to be routed around equipment and obstacles, although gradual bends are preferable to tight folds or sharp restrictions. Do bends in flexible ducting reduce airflow?
Excessive duct length, tight bends and compressed sections can increase resistance to airflow, so a direct and unrestricted route is preferable. Can this ducting be used with reducers and connectors?
Yes. Compatible round connectors, reducers, elbows and other ventilation fittings can be incorporated into the duct system as required. Should a 10m duct run be supported?
Yes. Longer sections should be supported where necessary to help prevent excessive sagging and maintain the intended duct route. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce the transmission of fan and airflow noise. Is this suitable for horticultural ventilation?
Yes. It is suitable for compatible ventilation systems used in propagation, nursery and controlled growing environments, as well as general ventilation applications.
£3.45
Unit price per£3.45
Unit price per102mm (4") x 5m COMBI Ducting is a flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length, making this 5 metre section a practical choice for connecting ventilation equipment where rigid ductwork would be less convenient.
With a nominal diameter of 102mm / 4", it is designed for use with compatible fans, filters, connectors, reducers and other round ventilation components.
Why choose COMBI ducting?
Flexible ducting for controlled environment ventilation
Effective ventilation depends on moving air between components with as little unnecessary resistance as practical. Flexible COMBI ducting makes it easier to create a complete duct route without requiring rigid sections throughout the installation.
It is suitable for connecting compatible extraction fans, air filters and ventilation fittings in propagation areas, growing areas, nurseries and other controlled horticultural environments.
The 5 metre length is particularly useful for individual ventilation runs, equipment connections and installations where several shorter sections of 102mm ducting are required.
Installing 102mm COMBI ducting
Extend the ducting to the required length and plan the route before making the final connections. Keeping the duct run reasonably direct helps reduce unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct, as restrictions in the airflow path can reduce ventilation performance.
Fit the duct securely over compatible 102mm connections and use an appropriately sized ducting clip or clamp to create a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Support the duct where necessary to prevent excessive sagging and to maintain a clean, unrestricted airflow path between components.
Getting the best airflow from flexible ducting
For efficient airflow, use the shortest practical duct route and minimise unnecessary bends. Flexible ducting should be extended sufficiently to avoid excessive bunching or compression between components.
Where a change in direction is required, a gradual bend is preferable to a tightly folded section. Keeping the internal airflow path as open as possible helps the connected fan operate more effectively.
Fan performance should be considered across the complete ventilation system, including duct length, bends, filters, silencers, reducers and other fittings installed in the airflow path.
102mm (4") x 5m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 102mm / 4" |
| Length | 5m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 102mm / 4" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
102mm (4") x 5m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical and robust way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 102mm, commonly referred to as 4-inch ducting. How long is the ducting?
This product is supplied as a 5 metre length. Can COMBI ducting be used with a 4-inch extraction fan?
Yes, it can be used with compatible fans designed for nominal 102mm / 4" ventilation connections. Can it connect to a carbon filter?
Yes. The ducting can be connected to a compatible 102mm carbon filter or to suitable adapters where different component sizes are being combined. Can COMBI ducting be used for air intake?
Yes. It can be used for both extraction and intake applications within a compatible ventilation system. Can I cut the 5m duct to shorter lengths?
Yes. Flexible ducting can be cut to suit the installation, allowing a single length to be divided into shorter sections where required. How should COMBI ducting be attached?
Fit the duct over a compatible connection and secure it with an appropriately sized ducting clip or clamp. HVAC foil tape can be added where further air sealing is required. Can the ducting bend around obstacles?
Yes. Its flexible construction allows it to be routed around equipment and obstacles, although gradual bends are preferable to tight folds or sharp restrictions. Do bends in flexible ducting reduce airflow?
Excessive duct length, tight bends and compressed sections can increase resistance to airflow, so a direct and unrestricted route is preferable. Can this ducting be used with reducers and connectors?
Yes. Compatible round connectors, reducers, elbows and other ventilation fittings can be incorporated into the duct system as required. Should flexible ducting be fully extended?
Where practical, extending the duct rather than leaving it heavily compressed helps create a smoother airflow path and reduces unnecessary restriction. Does flexible ducting need supporting?
It should be supported where necessary to prevent excessive sagging, particularly across horizontal runs or between widely spaced connection points. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce the transmission of fan and airflow noise. Is this suitable for horticultural ventilation?
Yes. It is suitable for compatible ventilation systems used in propagation, nursery and controlled growing environments, as well as general ventilation applications.
£6.45
Unit price per£6.45
Unit price per102mm (4") x 10m COMBI Ducting is a flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length. The generous 10 metre length is particularly useful for longer ventilation runs or where several shorter sections are required from one length.
With a nominal diameter of 102mm / 4", it is designed for use with compatible fans, filters, connectors, reducers and other round ventilation components.
Why choose COMBI ducting?
Flexible ducting for controlled environment ventilation
Effective ventilation depends on moving air between components with as little unnecessary resistance as practical. Flexible COMBI ducting makes it easier to create a complete duct route without requiring rigid sections throughout the installation.
It is suitable for connecting compatible extraction fans, air filters and ventilation fittings in propagation areas, growing areas, nurseries and other controlled horticultural environments.
The 10 metre length provides additional flexibility for larger installations, longer equipment connections or projects where multiple shorter sections of 102mm ducting are required.
Installing 102mm COMBI ducting
Extend the ducting to the required length and plan the route before making the final connections. Keeping the duct run reasonably direct helps reduce unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct, as restrictions in the airflow path can reduce ventilation performance.
Fit the duct securely over compatible 102mm connections and use an appropriately sized ducting clip or clamp to create a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Longer sections should be supported where necessary to prevent excessive sagging and to maintain a clean, unrestricted airflow path between components.
Getting the best airflow from flexible ducting
Although this product is supplied as a 10 metre length, there is no requirement to use the entire length in a single duct run. Using only the amount required for the installation can help reduce unnecessary resistance.
For efficient airflow, use the shortest practical route, minimise unnecessary bends and avoid leaving excessive compressed duct between components. Where a direction change is required, a gradual bend is preferable to a tightly folded section.
Fan performance should be considered across the complete ventilation system, including duct length, bends, filters, silencers, reducers and other fittings installed in the airflow path.
102mm (4") x 10m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 102mm / 4" |
| Length | 10m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 102mm / 4" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
102mm (4") x 10m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical and robust way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 102mm, commonly referred to as 4-inch ducting. How long is the ducting?
This product is supplied as a 10 metre length. Can COMBI ducting be used with a 4-inch extraction fan?
Yes, it can be used with compatible fans designed for nominal 102mm / 4" ventilation connections. Can it connect to a carbon filter?
Yes. The ducting can be connected to a compatible 102mm carbon filter or to suitable adapters where different component sizes are being combined. Can COMBI ducting be used for air intake?
Yes. It can be used for both extraction and intake applications within a compatible ventilation system. Can I cut the 10m duct to shorter lengths?
Yes. Flexible ducting can be cut to suit the installation, making the 10 metre length useful where several shorter sections are required. Do I need to use the full 10 metres?
No. Use only the length required. Keeping duct runs as short and direct as practical generally helps minimise resistance to airflow. How should COMBI ducting be attached?
Fit the duct over a compatible connection and secure it with an appropriately sized ducting clip or clamp. HVAC foil tape can be added where further air sealing is required. Can the ducting bend around obstacles?
Yes. Its flexible construction allows it to be routed around equipment and obstacles, although gradual bends are preferable to tight folds or sharp restrictions. Do bends in flexible ducting reduce airflow?
Excessive duct length, tight bends and compressed sections can increase resistance to airflow, so a direct and unrestricted route is preferable. Can this ducting be used with reducers and connectors?
Yes. Compatible round connectors, reducers, elbows and other ventilation fittings can be incorporated into the duct system as required. Should flexible ducting be fully extended?
Where practical, extending the duct rather than leaving it heavily compressed helps create a smoother airflow path and reduces unnecessary restriction. Should a 10m duct run be supported?
Yes. Longer sections should be supported where necessary to help prevent excessive sagging and maintain the intended duct route. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce the transmission of fan and airflow noise.
£11.69
Unit price per£11.69
Unit price per317mm (12.5") x 5m COMBI Ducting is a large-diameter flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length. Its large 317mm diameter makes it particularly suitable for higher-airflow ventilation systems using correspondingly sized fans, filters and fittings.
Supplied in a practical 5 metre length, the duct can be used as a complete run or cut into shorter sections to suit the installation.
Why choose COMBI ducting?
Large-diameter flexible ventilation ducting
Larger ventilation installations often require greater airflow capacity, making duct diameter an important part of system design. This 317mm COMBI ducting provides a flexible connection between compatible high-airflow ventilation components without requiring rigid ductwork throughout the entire system.
It can be used to connect appropriately sized extraction fans, air filters and ventilation fittings in propagation facilities, nurseries, growing areas and other controlled environments.
The 5 metre length provides useful flexibility for individual equipment connections and ventilation runs while allowing excess ducting to be removed where a shorter route is required.
Installing 317mm COMBI ducting
Plan the duct route before making the final connections and extend the ducting to the required length. Keeping the route reasonably short and direct helps minimise unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct. Restrictions become particularly important in higher-airflow systems because unnecessary resistance can affect overall ventilation performance.
Fit the duct securely over compatible 317mm connections and use an appropriately sized ducting clip or clamp to provide a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
The duct should be supported where necessary, particularly across longer horizontal sections, to prevent excessive sagging and maintain a clear airflow path.
Getting the best airflow from 317mm ducting
The performance of a ventilation system depends on more than fan capacity alone. Duct diameter, total duct length, bends, filters, reducers and other fittings all contribute to resistance within the airflow path.
Keep flexible ducting as straight and properly extended as practical. Where a direction change is required, use a gradual bend rather than sharply folding or compressing the duct.
There is no need to use the complete 5 metre length where a shorter connection is sufficient. Removing unnecessary duct length can help create a cleaner and less restrictive installation.
317mm (12.5") x 5m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 5m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
317mm (12.5") x 5m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 317mm, commonly referred to as 12.5-inch ducting. How long is the ducting?
This product is supplied as a 5 metre length. What is 317mm ducting typically used for?
Its large diameter makes it suitable for compatible higher-airflow extraction and intake systems using correspondingly sized ventilation equipment. Can it be connected to an extraction fan?
Yes. It can be used with a compatible fan designed for a nominal 317mm / 12.5" duct connection. Can 317mm COMBI ducting connect to an air filter?
Yes. It can be connected to compatible 317mm filters or incorporated into systems using suitable reducers and adapters where component sizes differ. Can COMBI ducting be used for air intake?
Yes. It is suitable for both extraction and intake applications within an appropriately designed ventilation system. Can I cut the 5m duct to shorter lengths?
Yes. The flexible ducting can be cut to suit the installation, allowing the 5 metre length to be divided where required. How should 317mm COMBI ducting be attached?
Fit the duct over the compatible connection and secure it using an appropriately sized ducting clip or clamp. HVAC foil tape can be used where additional air sealing is required. Can this ducting bend around obstacles?
Yes. The flexible construction allows the duct to be routed around equipment and obstacles, although gradual bends are preferable to tight folds. Do bends reduce airflow?
Tight bends, excessive duct length and compressed sections can increase airflow resistance. Keeping the route direct and unrestricted helps maintain system performance. Can I use a reducer with 317mm COMBI ducting?
Yes. A suitable ventilation reducer can be used to transition between different duct diameters where required by the system design. Should large flexible ducting be supported?
Yes. Supporting the duct where necessary helps prevent excessive sagging and keeps the intended airflow path open. Should flexible ducting be fully extended?
Where practical, the duct should be extended rather than left heavily compressed. This helps create a smoother internal airflow path and reduces unnecessary restriction. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce transmitted fan and airflow noise.
£19.90
Unit price per£19.90
Unit price per317mm (12.5") x 10m COMBI Ducting is a large-diameter flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It is well suited to ventilation systems where ductwork needs to negotiate equipment, corners or other obstacles while remaining easy to position.
The flexible construction allows the duct to be extended, routed and cut to the required length. Its large 317mm diameter makes it particularly suitable for higher-airflow ventilation systems using correspondingly sized fans, filters and fittings.
Supplied in a generous 10 metre length, the duct can be used for a longer continuous run or cut into multiple shorter sections to suit the installation.
Why choose COMBI ducting?
Large-diameter flexible ventilation ducting
Larger ventilation installations often require greater airflow capacity, making duct diameter an important part of system design. This 317mm COMBI ducting provides a flexible connection between compatible high-airflow ventilation components without requiring rigid ductwork throughout the entire system.
It can be used to connect appropriately sized extraction fans, air filters and ventilation fittings in propagation facilities, nurseries, growing areas and other controlled environments.
The 10 metre length is particularly useful where a longer duct run is required or where several shorter sections are needed from a single length.
Installing 317mm COMBI ducting
Plan the duct route before making the final connections and cut the ducting to the length actually required. Keeping the route reasonably short and direct helps minimise unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct. Restrictions become particularly important in higher-airflow systems because unnecessary resistance can affect overall ventilation performance.
Fit the duct securely over compatible 317mm connections and use an appropriately sized ducting clip or clamp to provide a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Longer horizontal runs should be supported at suitable intervals to reduce sagging and help maintain a clear airflow path.
Getting the best airflow from 317mm ducting
The performance of a ventilation system depends on more than fan capacity alone. Duct diameter, total duct length, bends, filters, reducers and other fittings all contribute to resistance within the airflow path.
Keep flexible ducting as straight and properly extended as practical. Where a direction change is required, use a gradual bend rather than sharply folding or compressing the duct.
There is no need to use the entire 10 metre length where a shorter run will do the job. Cutting the duct to the required length can reduce unnecessary resistance and create a cleaner installation.
317mm (12.5") x 10m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 317mm / 12.5" |
| Length | 10m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 317mm / 12.5" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
317mm (12.5") x 10m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical way to connect ventilation equipment while retaining the flexibility needed for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 317mm, commonly referred to as 12.5-inch ducting. How long is the ducting?
This product is supplied as a 10 metre length. What is 317mm ducting typically used for?
Its large diameter makes it suitable for compatible higher-airflow extraction and intake systems using correspondingly sized ventilation equipment. Can it be connected to an extraction fan?
Yes. It can be used with a compatible fan designed for a nominal 317mm / 12.5" duct connection. Can 317mm COMBI ducting connect to an air filter?
Yes. It can be connected to compatible 317mm filters or incorporated into systems using suitable reducers and adapters where component sizes differ. Can COMBI ducting be used for air intake?
Yes. It is suitable for both extraction and intake applications within an appropriately designed ventilation system. Can I cut the 10m duct into shorter lengths?
Yes. The ducting can be cut to suit the installation, making the 10 metre length useful where several separate sections are required. Do I need to use the entire 10m length?
No. Use only the length required for the installation. Keeping duct runs reasonably short and direct can help reduce unnecessary airflow resistance. How should 317mm COMBI ducting be attached?
Fit the duct over the compatible connection and secure it using an appropriately sized ducting clip or clamp. HVAC foil tape can be used where additional air sealing is required. Can this ducting bend around obstacles?
Yes. The flexible construction allows the duct to be routed around equipment and obstacles, although gradual bends are preferable to tight folds. Do bends reduce airflow?
Tight bends, excessive duct length and compressed sections can increase airflow resistance. Keeping the route direct and unrestricted helps maintain system performance. Can I use a reducer with 317mm COMBI ducting?
Yes. A suitable ventilation reducer can be used to transition between different duct diameters where required by the system design. Should long runs of flexible ducting be supported?
Yes. Supporting longer duct runs helps prevent excessive sagging and keeps the intended airflow path open. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce transmitted fan and airflow noise.
£16.99
Unit price per£16.99
Unit price per254mm (10") x 10m COMBI Ducting is a large-diameter flexible reinforced ventilation duct designed for reliable air movement in extraction and intake systems.
COMBI ducting combines the flexibility required for straightforward installation with a more robust outer construction than basic foil ducting. It provides a practical solution for connecting ventilation equipment where rigid ductwork would be difficult or unnecessary.
The flexible construction allows the duct to be extended, routed around equipment and cut to the required length. Its 254mm diameter makes it particularly suitable for higher-airflow ventilation systems using correspondingly sized fans, filters and fittings.
Supplied in a generous 10 metre length, it can be installed as a longer continuous duct run or divided into several shorter sections to suit the ventilation layout.
Why choose COMBI ducting?
Large-diameter flexible ventilation ducting
The diameter of a ventilation system has a significant influence on the volume of air it can move efficiently. This 254mm COMBI ducting is intended for larger ventilation installations where compatible 10-inch fans, filters and fittings are being used.
It can be used to create flexible connections between ventilation components in propagation facilities, nurseries, growing areas, controlled environments and other applications requiring dependable air extraction or intake.
The 10 metre length provides additional flexibility when planning larger installations and can be divided into individual sections where several duct connections are required.
Installing 254mm COMBI ducting
Plan the duct route before making the final connections and cut the ducting to the length actually required. Keeping the route reasonably short and direct helps minimise unnecessary airflow resistance.
Avoid excessively tight bends, severe compression or crushing the duct. Restrictions within the airflow path can increase resistance and reduce the effective performance of the ventilation system.
Fit the duct securely over compatible 254mm connections and use an appropriately sized ducting clip or clamp to provide a reliable mechanical fixing. Suitable HVAC foil tape can also be used where additional air sealing is required.
Longer horizontal runs should be supported at suitable intervals to reduce sagging and help maintain a clear airflow path.
Getting the best airflow from 254mm ducting
Fan performance is affected by the complete ventilation route. Duct length, bends, filters, reducers, connectors and other fittings all introduce resistance, so careful duct routing can make a significant difference to system performance.
Extend flexible ducting properly and keep it as straight as practical. Where a direction change is required, use a gradual bend rather than sharply folding or compressing the duct.
There is no need to use the entire 10 metre length where a shorter run will do the job. Cutting the duct to the required length helps avoid unnecessary resistance and creates a cleaner installation.
254mm (10") x 10m COMBI Ducting product details
| Product type | Reinforced flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 10m |
| Duct type | Flexible |
| Primary purpose | Air extraction & intake ventilation |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable connections | Compatible fans, filters, connectors, reducers & round ventilation fittings |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation installations |
254mm (10") x 10m COMBI Ducting FAQs
What is COMBI ducting?
COMBI ducting is flexible ventilation ducting with a reinforced outer construction, providing a practical way to connect ventilation equipment while retaining the flexibility required for installation. What diameter is this COMBI ducting?
This version has a nominal diameter of 254mm, commonly referred to as 10-inch ducting. How long is the ducting?
This product is supplied as a 10 metre length. What is 254mm ducting typically used for?
Its large diameter makes it suitable for compatible higher-airflow extraction and intake systems using correspondingly sized ventilation equipment. Can it be connected to a 10-inch extraction fan?
Yes. It can be used with a compatible fan designed for a nominal 254mm / 10" duct connection. Can 254mm COMBI ducting connect to an air filter?
Yes. It can be connected to compatible 254mm filters or incorporated into systems using suitable reducers and adapters where component sizes differ. Can COMBI ducting be used for air intake?
Yes. It is suitable for both extraction and intake applications within an appropriately designed ventilation system. Can I cut the 10m duct into shorter lengths?
Yes. The ducting can be cut to suit the installation, making the 10 metre length useful where several separate sections are required. Do I need to use the entire 10m length?
No. Use only the length required for the installation. Keeping duct runs reasonably short and direct can help reduce unnecessary airflow resistance. How should 254mm COMBI ducting be attached?
Fit the duct over the compatible connection and secure it using an appropriately sized ducting clip or clamp. HVAC foil tape can be used where additional air sealing is required. Can this ducting bend around obstacles?
Yes. Its flexible construction allows it to be routed around equipment and obstacles, although gradual bends are preferable to tight folds. Do bends reduce airflow?
Tight bends, excessive duct length and compressed sections can increase airflow resistance. Keeping the route direct and unrestricted helps maintain system performance. Can I use a reducer with 254mm COMBI ducting?
Yes. A suitable ventilation reducer can be used to transition between different duct diameters where required by the system design. Should long runs of flexible ducting be supported?
Yes. Supporting longer duct runs helps prevent excessive sagging and keeps the intended airflow path open. Is COMBI ducting the same as acoustic ducting?
No. COMBI ducting is primarily a reinforced flexible air duct. Acoustic ducting incorporates additional insulation specifically intended to help reduce transmitted fan and airflow noise.
£3.35
Unit price per£3.35
Unit price perThe 315mm (12.5") Fast Clamp provides a strong, secure and vibration-reducing connection between compatible circular ventilation components such as inline fans, filters and rigid duct fittings.
Rather than joining two pieces of ventilation equipment with a short section of flexible ducting, a Fast Clamp fits around the adjoining circular spigots to create a neat mechanical connection. This makes it particularly useful when installing fans directly alongside filters, silencers and other compatible ventilation equipment.
The galvanised steel outer band provides a strong connection, while the cushioned inner lining helps isolate vibration between connected components. Reducing the direct transfer of fan vibration into adjoining ductwork can help reduce structure-borne noise within a ventilation system.
The clamp can also be released when equipment needs to be removed, making it a practical choice for installations where fans or other components may require periodic inspection, cleaning or servicing.
Why use a 315mm Fast Clamp?
Connecting fans, filters and ventilation equipment
Fast Clamps are particularly useful where two compatible pieces of circular ventilation equipment need to be connected directly together. Typical examples include joining an inline extraction fan to a filter or connecting a fan to compatible rigid circular ductwork.
The cushioned lining sits between the metal clamp and the connected components, helping provide a secure fit while reducing the direct transmission of vibration from operating equipment into the rest of the ventilation system.
This makes Fast Clamps useful in propagation facilities, nurseries, growing areas, controlled environments and general ventilation installations where both secure connections and vibration management are important.
How to install a 315mm Fast Clamp
Position the two compatible 315mm circular components together so that their connection points are correctly aligned. Open or loosen the Fast Clamp sufficiently to position it evenly around the joint.
Make sure the cushioned inner lining sits correctly around the connection before tightening the clamp. Tighten the fixings evenly until the components are held securely in position.
Avoid excessive tightening beyond what is required to produce a secure connection. Fans, filters and other heavy ventilation equipment should always be independently supported rather than relying on the Fast Clamp to carry their weight.
315mm (12.5") Fast Clamp product details
| Product type | Anti-vibration ventilation Fast Clamp |
|---|---|
| Nominal connection size | 315mm / 12.5" |
| Outer construction | Galvanised steel |
| Inner construction | Cushioned anti-vibration lining |
| Primary purpose | Connecting compatible circular ventilation components |
| Vibration control | Inner lining helps reduce vibration transfer between connected components |
| Typical connections | Fans, filters, rigid circular ductwork & compatible ventilation fittings |
| Maintenance | Removable connection allows compatible equipment to be disconnected for servicing or cleaning |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation systems |
315mm (12.5") Fast Clamp FAQs
What is a ventilation Fast Clamp?
A Fast Clamp is a metal connector designed to securely join compatible circular ventilation components while its cushioned inner lining helps isolate vibration between them. What size is this Fast Clamp?
This model is designed for compatible ventilation components with a nominal 315mm / 12.5" circular connection. Can I use it to connect a fan to a filter?
Yes. Connecting compatible fans and filters is one of the common applications for this type of Fast Clamp. Can it connect a fan directly to rigid ducting?
Yes, provided the components have compatible nominal 315mm circular connections suitable for this type of clamp. Does a Fast Clamp reduce vibration?
Yes. The cushioned inner lining helps isolate vibration rather than allowing it to transfer directly from an operating fan into adjoining ductwork or equipment. Can reducing vibration make a ventilation system quieter?
It can help. Mechanical vibration transferred from a fan into ductwork can contribute to system noise, so isolating the connection can reduce this source of transmitted noise. Is the clamp made from metal?
Yes. The outer clamp is manufactured from galvanised steel and incorporates a cushioned inner lining. Can I remove the clamp again?
Yes. Fast Clamps are designed to provide a removable mechanical connection, making them useful where equipment may need to be disconnected for inspection, cleaning or servicing. Is a Fast Clamp better than joining equipment with ducting?
Where two compatible rigid circular components are positioned directly together, a Fast Clamp can provide a neater and more compact connection than using a short section of flexible ducting between them. Can I use this with 315mm ducting?
It is designed for compatible nominal 315mm circular ventilation connections. Always check the actual connection arrangement of the equipment being joined before installation. Does the Fast Clamp support the weight of a fan or filter?
No. Fans, filters and other substantial ventilation equipment should be properly and independently supported. The clamp is intended to secure the connection rather than act as the equipment's primary support. Where can 315mm Fast Clamps be used?
They are suitable for compatible circular ventilation systems in controlled environments, propagation facilities, nurseries, growing areas and other commercial or general ventilation applications.
£2.95
Unit price per£2.95
Unit price perThe 250mm (10") Fast Clamp provides a strong, secure and vibration-reducing connection between compatible circular ventilation components such as inline fans, filters and rigid duct fittings.
Rather than joining two pieces of ventilation equipment with a short section of flexible ducting, a Fast Clamp fits around the adjoining circular spigots to create a neat mechanical connection. This makes it particularly useful when installing fans directly alongside filters, silencers and other compatible ventilation equipment.
The galvanised steel outer band provides a strong connection, while the cushioned inner lining helps isolate vibration between connected components. Reducing the direct transfer of fan vibration into adjoining ductwork can help reduce structure-borne noise within a ventilation system.
The clamp can also be released when equipment needs to be removed, making it a practical choice for installations where fans or other components may require periodic inspection, cleaning or servicing.
Why use a 250mm Fast Clamp?
Connecting fans, filters and ventilation equipment
Fast Clamps are particularly useful where two compatible pieces of circular ventilation equipment need to be connected directly together. Typical examples include joining an inline extraction fan to a filter or connecting a fan to compatible rigid circular ductwork.
The cushioned lining sits between the metal clamp and the connected components, helping provide a secure fit while reducing the direct transmission of vibration from operating equipment into the rest of the ventilation system.
This makes Fast Clamps useful in propagation facilities, nurseries, growing areas, controlled environments and general ventilation installations where both secure connections and vibration management are important.
How to install a 250mm Fast Clamp
Position the two compatible 250mm circular components together so that their connection points are correctly aligned. Open or loosen the Fast Clamp sufficiently to position it evenly around the joint.
Make sure the cushioned inner lining sits correctly around the connection before tightening the clamp. Tighten the fixings evenly until the components are held securely in position.
Avoid excessive tightening beyond what is required to produce a secure connection. Fans, filters and other heavy ventilation equipment should be independently supported rather than relying on the Fast Clamp to carry their weight.
250mm (10") Fast Clamp product details
| Product type | Anti-vibration ventilation Fast Clamp |
|---|---|
| Nominal connection size | 250mm / 10" |
| Outer construction | Galvanised steel |
| Inner construction | Cushioned anti-vibration lining |
| Primary purpose | Connecting compatible circular ventilation components |
| Vibration control | Inner lining helps reduce vibration transfer between connected components |
| Typical connections | Fans, filters, rigid circular ductwork & compatible ventilation fittings |
| Maintenance | Removable connection allows compatible equipment to be disconnected for servicing or cleaning |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation systems |
250mm (10") Fast Clamp FAQs
What is a ventilation Fast Clamp?
A Fast Clamp is a metal connector designed to securely join compatible circular ventilation components while its cushioned inner lining helps isolate vibration between them. What size is this Fast Clamp?
This model is designed for compatible ventilation components with a nominal 250mm / 10" circular connection. Can I use it to connect a fan to a filter?
Yes. Connecting compatible fans and filters is one of the common applications for this type of Fast Clamp. Can it connect a fan directly to rigid ducting?
Yes, provided the components have compatible nominal 250mm circular connections suitable for this type of clamp. Does a Fast Clamp reduce vibration?
Yes. The cushioned inner lining helps isolate vibration rather than allowing it to transfer directly from an operating fan into adjoining ductwork or equipment. Can reducing vibration make a ventilation system quieter?
It can help. Mechanical vibration transferred from a fan into ductwork can contribute to system noise, so isolating the connection can reduce this source of transmitted noise. Is the Fast Clamp made from metal?
Yes. The outer clamp is manufactured from galvanised steel and incorporates a cushioned inner lining. Can the Fast Clamp be removed again?
Yes. The mechanical connection can be released, making it useful where equipment needs to be disconnected for inspection, cleaning or servicing. Is a Fast Clamp suitable for a direct fan-to-filter connection?
Yes, where the fan and filter have compatible 250mm circular connections and are correctly supported. Can I use this with 250mm ducting?
It is designed for compatible nominal 250mm circular ventilation connections. Check the actual connection arrangement of the components being joined before installation. Does the Fast Clamp support the weight of a fan or filter?
No. Fans, filters and other substantial ventilation equipment should be properly and independently supported. The Fast Clamp secures the connection rather than acting as the primary equipment support. Where can a 250mm Fast Clamp be used?
It is suitable for compatible circular ventilation systems in controlled environments, propagation facilities, nurseries, growing areas and other commercial or general ventilation applications.
£2.75
Unit price per£2.75
Unit price perThe 200mm (8") Fast Clamp provides a strong, secure and vibration-reducing connection between compatible circular ventilation components such as inline fans, filters and rigid duct fittings.
Rather than joining two pieces of ventilation equipment with a short section of flexible ducting, a Fast Clamp fits around adjoining circular spigots to create a neat mechanical connection. This makes it particularly useful when installing fans directly alongside filters, silencers and other compatible ventilation equipment.
The metal outer band provides a strong connection, while the cushioned inner lining helps isolate vibration between connected components. Reducing the direct transfer of fan vibration into adjoining ductwork can help reduce structure-borne noise within a ventilation system.
The clamp can also be released when equipment needs to be removed, making it a practical choice for installations where fans, filters or other components require periodic inspection, cleaning or servicing.
Why use a 200mm Fast Clamp?
Connecting fans, filters and ventilation equipment
Fast Clamps are particularly useful where two compatible pieces of circular ventilation equipment need to be connected directly together. A common application is joining an inline extraction fan to a compatible filter, although they can also be used with suitable rigid circular ducting and other ventilation components.
The cushioned inner lining sits between the outer clamp and the connected components. This helps create a secure connection while reducing the direct transmission of vibration from operating equipment into adjoining parts of the ventilation system.
This makes the 200mm Fast Clamp useful in propagation facilities, nurseries, growing areas, controlled environments and general ventilation installations where both secure connections and vibration management are important.
How to install a 200mm Fast Clamp
Position the two compatible 200mm circular components together so that their connection points are correctly aligned. Open or loosen the Fast Clamp sufficiently to position it evenly around the joint.
Make sure the cushioned inner lining sits correctly around the connection before tightening the clamp. Tighten the fixings evenly until the components are held securely in position.
Avoid excessive tightening beyond what is required to produce a secure connection. Fans, filters and other substantial ventilation equipment should be independently supported rather than relying on the Fast Clamp to carry their weight.
200mm (8") Fast Clamp product details
| Product type | Anti-vibration ventilation Fast Clamp |
|---|---|
| Nominal connection size | 200mm / 8" |
| Outer construction | Metal clamping band |
| Inner construction | Cushioned anti-vibration lining |
| Primary purpose | Connecting compatible circular ventilation components |
| Vibration control | Inner lining helps reduce vibration transfer between connected components |
| Typical connections | Fans, filters, rigid circular ductwork & compatible ventilation fittings |
| Maintenance | Removable connection allows compatible equipment to be disconnected for servicing or cleaning |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation systems |
200mm (8") Fast Clamp FAQs
What is a ventilation Fast Clamp?
A Fast Clamp is a mechanical connector designed to securely join compatible circular ventilation components while its cushioned inner lining helps isolate vibration between them. What size is this Fast Clamp?
This model is designed for compatible ventilation components with a nominal 200mm / 8" circular connection. Can I use it to connect a fan to a filter?
Yes. Connecting compatible fans and filters is one of the common applications for this type of Fast Clamp. Can it connect a fan directly to rigid ducting?
Yes, provided the components have compatible nominal 200mm circular connections suitable for this type of clamp. Does a Fast Clamp reduce vibration?
Yes. The cushioned inner lining helps isolate vibration rather than allowing it to transfer directly from an operating fan into adjoining ductwork or equipment. Can reducing vibration make a ventilation system quieter?
It can help. Mechanical vibration transferred from a fan into ductwork can contribute to system noise, so isolating the connection can help reduce this source of transmitted noise. Is the Fast Clamp made from metal?
Yes. The Fast Clamp uses a strong metal outer clamping band together with a cushioned inner lining. Can the Fast Clamp be removed again?
Yes. The mechanical connection can be released, making it useful where equipment needs to be disconnected for inspection, cleaning or servicing. Is a Fast Clamp suitable for a direct fan-to-filter connection?
Yes, where the fan and filter have compatible 200mm circular connections and both components are correctly supported. Can I use this with 200mm ventilation equipment?
It is intended for compatible nominal 200mm circular connections. Check the connection size and arrangement of the components being joined before installation. Does the Fast Clamp support the weight of a fan or filter?
No. Fans, filters and other substantial ventilation equipment should be properly and independently supported. The Fast Clamp secures the connection rather than acting as the primary equipment support. Why use a Fast Clamp instead of flexible ducting between components?
Where two compatible circular components are positioned directly together, a Fast Clamp provides a compact mechanical connection while also helping isolate vibration between the components. Where can a 200mm Fast Clamp be used?
It is suitable for compatible circular ventilation systems in controlled environments, propagation facilities, nurseries, growing areas and other commercial or general ventilation applications.
£1.99
Unit price per£1.99
Unit price perThe 150mm (6") Fast Clamp provides a strong, secure and vibration-reducing connection between compatible circular ventilation components such as inline fans, filters and rigid duct fittings.
Rather than joining two pieces of ventilation equipment with a short section of flexible ducting, a Fast Clamp fits around adjoining circular spigots to create a neat mechanical connection. This makes it particularly useful when installing fans directly alongside filters, silencers and other compatible ventilation equipment.
The strong metal outer band provides a secure connection, while the cushioned inner lining helps isolate vibration between connected components. Reducing the direct transfer of fan vibration into adjoining equipment and ductwork can help reduce structure-borne noise within the ventilation system.
The clamp can also be released when equipment needs to be removed, making it a practical choice for installations where fans, filters or other components require periodic inspection, cleaning or servicing.
Why use a 150mm Fast Clamp?
Connecting fans, filters and ventilation equipment
Fast Clamps are particularly useful where two compatible pieces of circular ventilation equipment need to be connected directly together. A common application is joining an inline extraction fan to a compatible filter, although they can also be used with suitable silencers, rigid circular ductwork and other ventilation fittings.
The cushioned inner lining sits between the outer clamp and the connected components. This helps create a secure fit while reducing the direct transmission of vibration from operating equipment into adjoining parts of the ventilation system.
This makes the 150mm Fast Clamp useful in propagation facilities, nurseries, growing areas, controlled environments and general ventilation installations where secure connections and vibration management are important.
How to install a 150mm Fast Clamp
Position the two compatible 150mm circular components together so their connection points are correctly aligned. Open or loosen the Fast Clamp sufficiently to position it evenly around the joint.
Make sure the cushioned inner lining sits correctly around the connection before tightening the clamp. Tighten the fixings evenly until the components are held securely in position.
Avoid excessive tightening beyond what is required to produce a secure connection. Fans, filters and other substantial ventilation equipment should be independently supported rather than relying on the Fast Clamp to carry their weight.
150mm (6") Fast Clamp product details
| Product type | Anti-vibration ventilation Fast Clamp |
|---|---|
| Nominal connection size | 150mm / 6" |
| Outer construction | Metal clamping band |
| Inner construction | Cushioned anti-vibration lining |
| Primary purpose | Connecting compatible circular ventilation components |
| Vibration control | Inner lining helps reduce vibration transfer between connected components |
| Typical connections | Fans, filters, silencers, rigid circular ductwork & compatible ventilation fittings |
| Maintenance | Removable connection allows compatible equipment to be disconnected for servicing or cleaning |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation systems |
150mm (6") Fast Clamp FAQs
What is a ventilation Fast Clamp?
A Fast Clamp is a mechanical connector designed to securely join compatible circular ventilation components while its cushioned inner lining helps isolate vibration between them. What size is this Fast Clamp?
This model is designed for compatible ventilation components with a nominal 150mm / 6" circular connection. Can I use it to connect a 6-inch fan to a filter?
Yes. Connecting compatible fans and filters is one of the common applications for a 150mm Fast Clamp. Can it connect a fan directly to rigid ducting?
Yes, provided the components have compatible nominal 150mm circular connections suitable for this type of clamp. Can a Fast Clamp connect a fan to a silencer?
Yes. It can be used between compatible 150mm circular fan and silencer connections where the equipment is correctly aligned and independently supported. Does a Fast Clamp reduce vibration?
Yes. The cushioned inner lining helps isolate vibration rather than allowing it to transfer directly from an operating fan into adjoining ductwork or equipment. Can reducing vibration make a ventilation system quieter?
It can help. Mechanical vibration transferred from a fan into ductwork can contribute to system noise, so isolating the connection can help reduce this source of transmitted noise. Is the Fast Clamp made from metal?
Yes. The Fast Clamp uses a strong metal outer clamping band together with a cushioned inner lining. Can the Fast Clamp be removed again?
Yes. The mechanical connection can be released, making it useful where equipment needs to be disconnected for inspection, cleaning or servicing. Is a Fast Clamp suitable for a direct fan-to-filter connection?
Yes, where the fan and filter have compatible 150mm circular connections and both components are correctly supported. Does the Fast Clamp support the weight of a fan or filter?
No. Fans, filters and other substantial ventilation equipment should be properly and independently supported. The Fast Clamp secures the connection rather than acting as the primary equipment support. Why use a Fast Clamp instead of flexible ducting between components?
Where two compatible circular components are positioned directly together, a Fast Clamp provides a compact mechanical connection while also helping isolate vibration between the components. Where can a 150mm Fast Clamp be used?
It is suitable for compatible circular ventilation systems in controlled environments, propagation facilities, nurseries, growing areas and other commercial or general ventilation applications.
£1.45
Unit price per£1.45
Unit price perThe 100mm (4") Fast Clamp provides a strong, secure and vibration-reducing connection between compatible circular ventilation components such as inline fans, filters and rigid duct fittings.
Rather than joining two pieces of ventilation equipment with a short section of flexible ducting, a Fast Clamp fits around adjoining circular spigots to create a neat mechanical connection. This makes it particularly useful when installing fans directly alongside filters, silencers and other compatible ventilation equipment.
The strong metal outer band provides a secure connection, while the cushioned inner lining helps isolate vibration between connected components. Reducing the direct transfer of fan vibration into adjoining equipment and ductwork can help reduce structure-borne noise within the ventilation system.
The clamp can also be released when equipment needs to be removed, making it a practical choice for installations where fans, filters or other components require periodic inspection, cleaning or servicing.
Why use a 100mm Fast Clamp?
Connecting fans, filters and ventilation equipment
Fast Clamps are particularly useful where two compatible pieces of circular ventilation equipment need to be connected directly together. A common application is joining an inline extraction fan to a compatible filter, although they can also be used with suitable silencers, rigid circular ductwork and other ventilation fittings.
The cushioned inner lining sits between the outer clamp and the connected components. This helps create a secure fit while reducing the direct transmission of vibration from operating equipment into adjoining parts of the ventilation system.
This makes the 100mm Fast Clamp useful in propagation areas, nurseries, growing areas, controlled environments and general ventilation installations where secure connections and vibration management are important.
How to install a 100mm Fast Clamp
Position the two compatible 100mm circular components together so their connection points are correctly aligned. Open or loosen the Fast Clamp sufficiently to position it evenly around the joint.
Make sure the cushioned inner lining sits correctly around the connection before tightening the clamp. Tighten the fixings evenly until the components are held securely in position.
Avoid excessive tightening beyond what is required to produce a secure connection. Fans, filters and other substantial ventilation equipment should be independently supported rather than relying on the Fast Clamp to carry their weight.
100mm (4") Fast Clamp product details
| Product type | Anti-vibration ventilation Fast Clamp |
|---|---|
| Nominal connection size | 100mm / 4" |
| Outer construction | Metal clamping band |
| Inner construction | Cushioned anti-vibration lining |
| Primary purpose | Connecting compatible circular ventilation components |
| Vibration control | Inner lining helps reduce vibration transfer between connected components |
| Typical connections | Fans, filters, silencers, rigid circular ductwork & compatible ventilation fittings |
| Maintenance | Removable connection allows compatible equipment to be disconnected for servicing or cleaning |
| Suitable applications | Controlled environment, propagation, nursery, growing area & general ventilation systems |
100mm (4") Fast Clamp FAQs
What is a ventilation Fast Clamp?
A Fast Clamp is a mechanical connector designed to securely join compatible circular ventilation components while its cushioned inner lining helps isolate vibration between them. What size is this Fast Clamp?
This model is designed for compatible ventilation components with a nominal 100mm / 4" circular connection. Can I use it to connect a 4-inch fan to a filter?
Yes. Connecting compatible fans and filters is one of the common applications for a 100mm Fast Clamp. Can it connect a fan directly to rigid ducting?
Yes, provided the components have compatible nominal 100mm circular connections suitable for this type of clamp. Can a Fast Clamp connect a fan to a silencer?
Yes. It can be used between compatible 100mm circular fan and silencer connections where the equipment is correctly aligned and independently supported. Does a Fast Clamp reduce vibration?
Yes. The cushioned inner lining helps isolate vibration rather than allowing it to transfer directly from an operating fan into adjoining ductwork or equipment. Can reducing vibration make a ventilation system quieter?
It can help. Mechanical vibration transferred from a fan into ductwork can contribute to system noise, so isolating the connection can help reduce this source of transmitted noise. Is the Fast Clamp made from metal?
Yes. The Fast Clamp uses a strong metal outer clamping band together with a cushioned inner lining. Can the Fast Clamp be removed again?
Yes. The mechanical connection can be released, making it useful where equipment needs to be disconnected for inspection, cleaning or servicing. Is a Fast Clamp suitable for a direct fan-to-filter connection?
Yes, where the fan and filter have compatible 100mm circular connections and both components are correctly supported. Does the Fast Clamp support the weight of a fan or filter?
No. Fans, filters and other substantial ventilation equipment should be properly and independently supported. The Fast Clamp secures the connection rather than acting as the primary equipment support. Why use a Fast Clamp instead of flexible ducting between components?
Where two compatible circular components are positioned directly together, a Fast Clamp provides a compact mechanical connection while also helping isolate vibration between the components. Where can a 100mm Fast Clamp be used?
It is suitable for compatible circular ventilation systems in controlled environments, propagation facilities, nurseries, growing areas and other commercial or general ventilation applications.