What is the airflow of the K-Line+ 12.5" Silent EC Fan?
The 12.5" K-Line+ is rated at a maximum airflow of 3200m³/h, making it suitable for high-capacity ventilation applications.
4 products
4 products
Sort by:
£265.00
Unit price per£265.00
Unit price perThe K-Line+ 12.5" Silent EC Fan combines powerful 3200m³/h airflow with an acoustically treated cylindrical housing and energy-efficient EC fan technology, providing high-capacity ventilation with reduced operating noise.
Designed for demanding extraction and air-movement applications, this larger K-Line+ model delivers a maximum airflow of 3200m³/h through a 12.5" duct connection. It is particularly well suited to larger controlled horticultural environments where substantial airflow is required but fan noise needs to be kept under control.
Unlike a conventional inline fan installed inside a separate silencer, the K-Line+ combines the fan and acoustic treatment within one compact cylindrical assembly. This helps reduce the amount of additional ventilation equipment required while keeping installation straightforward.
At the centre of the unit is an electronically commutated EC fan. EC technology combines efficient motor operation with variable-speed capability, allowing airflow to be matched more closely to the requirements of the ventilation system rather than continually operating at maximum output.
Why choose the K-Line+ 12.5" Silent EC Fan?
High airflow without a conventional bare fan housing
High-capacity ventilation fans can generate noise from several sources, including the motor, impeller, moving air and vibration transferred into the connected ductwork.
The K-Line+ is designed specifically as a silenced inline fan. The fan assembly sits within the larger cylindrical acoustic housing rather than using the compact exposed casing typically found on a conventional inline fan.
This construction helps reduce fan noise at source while maintaining a straight-through ventilation path. For installations where noise control is important, it can be combined with acoustic ducting, vibration-isolating connectors and correctly supported duct runs to further reduce noise transmission through the ventilation system.
As with any high-output ventilation fan, the K-Line+ should not be considered completely silent. Airflow noise will still depend on fan speed, duct diameter, restrictions and the design of the complete ventilation system.
Efficient EC fan technology
EC stands for electronically commutated. An EC fan uses integrated electronic motor control rather than the simpler motor technology found in many traditional AC ventilation fans.
One of the major advantages is efficient variable-speed operation. Instead of treating the fan simply as an on/off device, a compatible control system can reduce airflow when full extraction capacity is unnecessary and increase it as ventilation demand rises.
This makes EC ventilation particularly useful in controlled environments where airflow requirements change with temperature, humidity, lighting load, crop development and seasonal conditions.
3200m³/h maximum airflow
With a rated maximum airflow of 3200 cubic metres per hour, this 12.5" K-Line+ is intended for applications requiring substantial air exchange.
The quoted figure represents the fan's maximum nominal airflow. Actual airflow through an installed ventilation system will normally be lower because every component introduces resistance.
Carbon filters, long duct runs, bends, reducers, silencers, intake restrictions and compressed flexible ducting can all reduce the volume of air delivered by the complete system.
When specifying ventilation, the fan should therefore be selected according to the resistance and required operating airflow of the complete installation rather than simply matching the room volume to the fan's maximum free-air rating.
12.5" high-capacity duct connection
The K-Line+ 3200m³/h model is designed around a 12.5" nominal duct connection, placing it firmly in the high-airflow end of an environmental ventilation system.
Keeping the ductwork at the correct diameter helps minimise unnecessary static pressure and air velocity. Reducing immediately into substantially smaller ducting can restrict airflow and increase turbulence and noise.
For best performance, use appropriately sized ducting and fittings, keep the route as short and direct as practical, and avoid unnecessary tight bends.
Building a quieter ventilation system
A silenced fan can significantly improve the acoustic performance of a ventilation system, but the complete installation determines the final noise level.
Correct system design can reduce turbulence, restriction and vibration while allowing the EC fan to deliver the required airflow at the lowest practical operating speed.
Using the K-Line+ with a carbon filter
The K-Line+ can be incorporated into a filtered extraction system using a suitably sized carbon filter and compatible ductwork.
The filter must be capable of handling the required airflow. An undersized filter can create excessive resistance, reducing extraction performance and potentially increasing airflow noise.
Remember that the fan's 3200m³/h rating is its maximum nominal airflow rather than a guarantee of 3200m³/h through a filter and complete duct system. Filter resistance should be considered when sizing the installation.
K-Line+ 12.5" Silent EC Fan product details
| Brand | K-Line+ |
|---|---|
| Product type | Silenced inline EC ventilation fan |
| Nominal size | 12.5" |
| Maximum airflow | 3200m³/h |
| Motor technology | EC - electronically commutated |
| Speed capability | Variable-speed EC fan |
| Construction | Cylindrical silenced inline fan assembly |
| Installation type | Inline ventilation |
| Typical application | High-capacity extraction, intake & controlled-environment ventilation |
| Pallet quantity | 12 fans |
K-Line+ 12.5" Silent EC Fan FAQs
What is the airflow of the K-Line+ 12.5" Silent EC Fan?
The 12.5" K-Line+ is rated at a maximum airflow of 3200m³/h, making it suitable for high-capacity ventilation applications. Is the K-Line+ 3200m³/h fan completely silent?
No high-output ventilation fan is completely silent. The K-Line+ uses a silenced construction designed to reduce operating noise, but the final sound level will also depend on fan speed, ductwork, filters, airflow restrictions and installation method. What does EC mean on the K-Line+ fan?
EC means electronically commutated. EC motors use integrated electronics to provide efficient operation and variable-speed capability. Can the K-Line+ EC fan be speed controlled?
EC fan technology is designed for variable-speed operation. The control method used must be electrically compatible with the specific fan and its control interface. What size ducting should I use with the 12.5" K-Line+?
Use ducting and fittings matched to the fan's nominal 12.5" connection wherever practical. Maintaining the correct diameter helps reduce unnecessary restriction, turbulence and airflow noise. Can the K-Line+ be used with acoustic ducting?
Yes. Acoustic insulated ducting can be used as part of a low-noise ventilation installation and can help reduce noise transmitted along the duct run. Can the K-Line+ be connected to a carbon filter?
Yes. A suitable carbon filter can be incorporated into the extraction system, but it should be correctly sized for the required airflow and its resistance should be considered when specifying the fan. Will I get exactly 3200m³/h through a carbon filter?
Not normally. The 3200m³/h figure is the fan's maximum nominal airflow. Filters, ducting, bends and other restrictions create resistance and reduce the airflow delivered by the complete installed system. Do bends in ducting reduce airflow?
Yes. Bends increase resistance and turbulence, particularly when they are tight or numerous. Keeping the duct route short and direct helps preserve airflow and reduce noise. Why use a larger 12.5" ventilation connection?
A larger duct diameter allows substantial volumes of air to be moved without forcing the same airflow through a much smaller cross-sectional area. Correctly sized ducting can therefore help reduce restriction and excessive air velocity. Can I reduce the K-Line+ into smaller ducting?
A suitable reducer can be used where necessary, but reducing duct diameter increases system resistance and may reduce airflow while increasing turbulence and noise. Keep the full fan diameter for as much of the system as practical. Can the K-Line+ be used as an intake fan?
It can form part of an intake or extraction ventilation system where its airflow, direction, duct size and control requirements are appropriate for the installation. How can I make a K-Line+ installation quieter?
Use correctly sized ducting, minimise sharp bends and restrictions, consider acoustic ducting, isolate vibration where practical and operate the EC fan at the lowest speed that still provides the required environmental airflow. Is the 3200m³/h K-Line+ suitable for larger controlled environments?
Yes. Its high maximum airflow makes it particularly suited to larger controlled horticultural environments and ventilation systems where a smaller inline fan cannot provide sufficient air movement. How many K-Line+ 12.5" fans are on a pallet?
The pallet quantity for this SKU is 12 fans.
£195.00
Unit price per£195.00
Unit price perThe K-Line+ 10" Silent EC Fan combines powerful 2300m³/h airflow with an acoustically treated cylindrical housing and energy-efficient EC fan technology, providing high-capacity ventilation with reduced operating noise.
Designed for demanding extraction and air-movement applications, this K-Line+ model delivers a maximum airflow of 2300m³/h through a 10" duct connection. It provides substantial ventilation capacity for larger controlled horticultural environments while keeping fan noise under control.
The K-Line+ combines the fan and acoustic treatment within one compact inline assembly. This reduces the need to install a conventional exposed inline fan inside a separate acoustic enclosure and provides a clean, straightforward solution for high-airflow ventilation systems.
At the centre of the unit is an electronically commutated EC fan. EC technology provides efficient motor operation together with variable-speed capability, allowing airflow to be adjusted to suit the ventilation demand rather than continually operating at maximum output.
Why choose the K-Line+ 10" Silent EC Fan?
High airflow with reduced fan noise
High-output ventilation can generate significant noise from the fan motor, impeller, airflow turbulence and vibration transmitted into connected ductwork.
The K-Line+ is designed specifically as a silenced inline fan. Its fan assembly is contained within a larger cylindrical acoustic housing rather than relying on the compact exposed casing found on many conventional inline fans.
This construction helps reduce fan noise at source while maintaining the straight-through airflow path required for an efficient ducted ventilation system.
For installations where acoustic performance is particularly important, the fan can be combined with insulated acoustic ducting, vibration-reducing connectors and correctly supported ductwork to further reduce noise transmission.
No high-capacity ventilation fan is completely silent. The final sound level will depend on fan speed, airflow, ducting, filters, bends, restrictions and the way the complete ventilation system is installed.
Efficient EC fan technology
EC stands for electronically commutated. EC motors use integrated electronic control to provide efficient operation and effective variable-speed performance.
This is particularly useful in controlled horticultural environments because maximum extraction is not necessarily required continuously. Ventilation demand can change throughout the day as temperature, humidity, lighting load and external conditions change.
With an appropriate compatible control method, the K-Line+ can be operated at a reduced speed when ventilation demand is lower and increased when additional airflow is required.
Running the fan only as hard as necessary can also help reduce airflow noise compared with operating a high-capacity ventilation system continuously at full output.
2300m³/h maximum airflow
The 10" K-Line+ provides a maximum nominal airflow of 2300 cubic metres per hour, giving it the capacity required for substantial extraction and air-exchange systems.
Maximum fan airflow should not be confused with the airflow that will necessarily be achieved once the fan is installed. Every component within a ventilation system introduces resistance.
Carbon filters, long duct runs, bends, reducers, silencers, intake restrictions and compressed flexible ducting can all reduce actual airflow.
When specifying a ventilation system, consider both the required air-exchange rate and the resistance created by the complete installation.
10" high-airflow duct connection
This K-Line+ model is designed around a 10" nominal duct connection, making it suitable for ventilation systems where substantial volumes of air need to be moved efficiently.
Maintaining the correct duct diameter helps minimise unnecessary static pressure and excessive air velocity. Reducing immediately into significantly smaller ductwork can restrict the system, lower airflow and increase turbulence and noise.
For best performance, use correctly sized ducting and fittings, keep the duct route as short and direct as practical and minimise unnecessary tight bends.
Suitable for filtered extraction systems
The K-Line+ can be incorporated into a filtered extraction system using an appropriately sized carbon filter and compatible ductwork.
Filter capacity is important. An undersized filter can create excessive resistance, significantly reducing airflow through the installation and potentially increasing fan and airflow noise.
The fan's 2300m³/h figure is its maximum nominal airflow. Actual airflow through a carbon filter and complete duct system will normally be lower, so the resistance of the filter and ductwork should be considered when sizing the system.
Getting the best performance from the K-Line+
A well-designed ventilation system reduces unnecessary resistance and allows the fan to provide the required environmental airflow at the lowest practical operating speed.
K-Line+ 10" Silent EC Fan product details
| Brand | K-Line+ |
|---|---|
| Product type | Silenced inline EC ventilation fan |
| Nominal size | 10" |
| Maximum airflow | 2300m³/h |
| Motor technology | EC - electronically commutated |
| Speed capability | Variable-speed EC fan |
| Construction | Cylindrical silenced inline fan assembly |
| Installation type | Inline ventilation |
| Typical applications | Extraction, intake, filtered ventilation & controlled-environment air movement |
| Pallet quantity | 15 fans |
K-Line+ 10" Silent EC Fan FAQs
What is the airflow of the K-Line+ 10" Silent EC Fan?
The 10" K-Line+ is rated at a maximum airflow of 2300m³/h. Is the K-Line+ 2300m³/h fan completely silent?
No. The K-Line+ uses an acoustically treated construction to reduce operating noise, but any high-output ventilation system will still produce some fan and airflow noise. What does EC mean?
EC stands for electronically commutated. This motor technology provides efficient operation and allows effective variable-speed control when used with an appropriate compatible controller. Can the K-Line+ 10" EC fan be speed controlled?
Yes. EC fan technology supports variable-speed operation, although the controller and control method must be compatible with the fan. What size ducting should I use with this K-Line+ fan?
Use ducting and fittings matched to the fan's nominal 10" connection wherever practical. Correctly sized ductwork helps minimise restriction, turbulence and excessive airflow noise. Can I use acoustic ducting with the K-Line+?
Yes. Acoustic insulated ducting can complement the fan's silenced construction by helping reduce noise transmitted along the ventilation system. Can the K-Line+ be connected to a carbon filter?
Yes. The fan can form part of a filtered extraction system when used with an appropriately sized carbon filter and compatible ductwork. Will a carbon filter reduce the 2300m³/h airflow?
Yes. A carbon filter creates resistance, so actual installed airflow will be lower than the fan's maximum nominal airflow. The amount of reduction depends on the filter and the rest of the ventilation system. Do duct bends reduce airflow?
Yes. Bends increase resistance and turbulence. Keeping the duct route as straight and direct as practical helps preserve airflow and reduce unnecessary noise. Can I reduce the fan into smaller ducting?
A suitable reducer can be used where necessary, but reducing the duct diameter increases resistance and can reduce airflow while increasing air velocity and noise. Can the K-Line+ 2300m³/h fan be used for intake?
Yes. It can form part of either an intake or extraction system where the required airflow, duct sizing and installation design are appropriate. How can I reduce ventilation noise further?
Use correctly sized ducting, minimise bends and restrictions, consider acoustic ducting, isolate vibration where practical and use compatible EC speed control so the fan does not operate faster than necessary. Is 2300m³/h the actual airflow after installation?
Not necessarily. 2300m³/h is the maximum nominal fan airflow. Filters, duct length, bends, reducers and other restrictions will affect the actual airflow delivered by the installed system. Is this fan suitable for larger controlled horticultural environments?
Yes. Its combination of 2300m³/h maximum airflow, 10" connection, EC technology and silenced construction makes it well suited to larger controlled environments requiring substantial ventilation. How many K-Line+ 10" 2300m³/h fans are on a pallet?
The pallet quantity for this SKU is 15 fans.
£92.50
Unit price per£92.50
Unit price perThe U-GO 8" 200mm EC Extraction Fan delivers up to 1230m³/h of airflow using an efficient 9-pole digital EC brushless motor, with a detachable digital thermostatic controller included as standard for variable-speed and temperature-responsive ventilation control.
Designed for powerful but controllable air movement, the U-GO combines a 200mm / 8" connection with 1230m³/h maximum airflow. Its EC motor technology provides efficient variable-speed operation while producing the static pressure required to work effectively within real ventilation systems containing ducting, bends and carbon filters.
Unlike a basic fixed-speed extraction fan, the U-GO is supplied with its own detachable digital controller. This provides fully variable fan-speed control together with thermostatic temperature control, allowing ventilation to respond more closely to changing environmental conditions.
The fan is built around a sturdy steel housing with ABEC 7 ball bearings and is also compatible with external 0-10V control via RJ9 or RJ11 connection, providing additional options when integrating it into a more advanced environmental-control system.
Why choose the U-GO 8" EC Extraction Fan?
9-pole digital EC brushless motor
At the centre of the U-GO is a 9-pole digital EC brushless motor. EC stands for electronically commutated, combining a brushless motor design with electronic control.
This technology is particularly well suited to environmental ventilation because fan speed can be varied efficiently rather than relying solely on full-power operation.
U-GO states a fan efficiency of 7.85 CFM per watt, with the design intended to provide both strong linear airflow and static-pressure performance.
Static pressure becomes particularly important once a fan is connected to real ventilation equipment. Carbon filters, ducting, bends and other components all resist airflow, so a fan's ability to maintain useful airflow against resistance matters as much as its unrestricted maximum airflow figure.
Digital thermostatic controller included
Every U-GO fan is supplied with a detachable digital controller, giving the user direct control over fan operation without needing to purchase a separate basic speed controller.
The controller provides fully variable speed adjustment and thermostatic temperature control. This allows ventilation to be configured around the required environment rather than simply running the extraction fan at maximum speed continuously.
When environmental demand is lower, reducing fan speed can decrease unnecessary airflow, electrical consumption and ventilation noise. As additional cooling or air exchange becomes necessary, fan output can be increased.
This makes the U-GO particularly useful where ventilation requirements vary as lighting load, external temperature and other environmental conditions change.
1230m³/h high-airflow ventilation
The 8" U-GO provides a maximum airflow of 1230 cubic metres per hour, making it suitable for substantial intake or extraction applications.
Maximum airflow figures describe fan performance under defined conditions and should not be confused with the airflow that will necessarily be achieved after installation.
Carbon filters, long duct runs, tight bends, reducers, silencers and compressed flexible ducting all introduce resistance and can reduce actual system airflow.
Keeping the ventilation route short, correctly sized and as direct as practical helps the U-GO make better use of its available airflow and static-pressure capability.
0-10V environmental controller compatibility
In addition to its supplied digital controller, the U-GO supports 0-10V external control via RJ9 or RJ11 connection.
A 0-10V control signal allows compatible environmental-control equipment to regulate EC fan speed without controlling the fan by simply reducing its mains supply.
This provides scope for integrating the fan into more advanced ventilation strategies where compatible equipment is being used.
Always confirm the connection, control signal and cable requirements of the external controller before connecting third-party environmental-control equipment.
Ideal for carbon-filtered extraction
The U-GO's combination of high airflow and static-pressure performance makes it well suited to carbon-filtered extraction systems.
A carbon filter naturally creates resistance as air is pulled through the activated carbon bed. The fan therefore needs enough pressure capability to maintain the required ventilation rate once the filter is installed.
For best results, match the fan with a carbon filter of suitable airflow capacity and connection diameter. A variable-speed EC fan is particularly useful because airflow can then be adjusted to suit both the filter and the environmental requirement.
Getting the best performance from the U-GO 200mm Fan
Correct ventilation design allows the fan to provide the required air exchange at the lowest practical operating speed, helping balance environmental control, energy use and noise.
U-GO 8" 200mm EC Fan product details
| Brand | U-GO |
|---|---|
| Product type | Digital EC inline extraction fan |
| Nominal connection | 8" / 200mm |
| Maximum airflow | 1230m³/h |
| Motor technology | 9-pole digital EC brushless motor |
| Stated fan efficiency | 7.85 CFM per watt |
| Speed control | Fully variable |
| Digital controller | Included |
| Temperature control | Thermostatic control via supplied digital controller |
| External control | 0-10V compatible |
| Control connection | RJ9 or RJ11 |
| Housing | Steel |
| Bearings | ABEC 7 ball bearings |
| Typical applications | Extraction, intake, carbon-filtered ventilation & controlled-environment air movement |
U-GO 8" 200mm EC Extraction Fan FAQs
What is the airflow of the U-GO 8" fan?
The 200mm / 8" U-GO EC Fan has a maximum airflow rating of 1230m³/h. Does the U-GO fan include a controller?
Yes. A detachable digital thermostatic fan controller is included with the fan as standard. Can I vary the speed of the U-GO fan?
Yes. The supplied controller provides fully variable fan-speed control, allowing airflow to be adjusted to the requirements of the ventilation system. Does the controller respond to temperature?
Yes. The supplied digital controller provides thermostatic temperature control as well as variable fan-speed adjustment. What does EC mean?
EC stands for electronically commutated. The U-GO uses a 9-pole digital EC brushless motor designed for efficient and controllable fan operation. How efficient is the U-GO EC fan?
U-GO states fan efficiency at 7.85 CFM per watt for this EC fan range. Can I use an external 0-10V controller?
Yes. The U-GO is compatible with 0-10V control via an appropriate RJ9 or RJ11 connection. Always check the requirements of the external controller and cable before connection. Can I connect the U-GO to a carbon filter?
Yes. Its airflow and static-pressure capability make it suitable for carbon-filtered extraction when paired with an appropriately sized filter. What size carbon filter should I use?
Ideally use a 200mm / 8" carbon filter with airflow capacity appropriate to the fan and required ventilation rate. Filter resistance should also be considered when sizing the complete system. Will a carbon filter reduce the fan's 1230m³/h airflow?
Yes. A carbon filter creates resistance, so actual installed airflow will normally be lower than the fan's unrestricted maximum airflow rating. What size ducting does the U-GO 8" fan require?
The fan has a nominal 200mm / 8" connection, so matching 200mm ducting and fittings should be used wherever practical. Can I reduce the U-GO fan into smaller ducting?
A reducer can be used where necessary, but reducing duct diameter increases system resistance and air velocity and can reduce overall airflow. What are ABEC 7 ball bearings?
The U-GO motor assembly uses ABEC 7 ball bearings, providing a precision bearing system for smooth fan operation. Can the U-GO be used as an intake fan?
Yes. The fan can be incorporated into appropriately designed intake or extraction ventilation systems. How can I get the best airflow from the U-GO fan?
Use correctly sized 200mm ducting, minimise tight bends and restrictions, avoid compressed flexible ducting and ensure filters and other ventilation components are appropriately sized for the required airflow.
£119.00
Unit price per£119.00
Unit price perThe U-GO 10" 250mm EC Extraction Fan delivers up to 1840m³/h of airflow using a 9-pole digital EC brushless motor, with a detachable digital thermostatic controller included for fully variable fan-speed and temperature-responsive ventilation control.
Designed for high-capacity ventilation systems, the U-GO combines a 250mm / 10" connection with 1840m³/h maximum airflow. Its EC motor technology provides efficient variable-speed operation together with strong static-pressure performance for installations containing carbon filters, ducting and other airflow restrictions.
A detachable digital controller is included, providing both variable fan-speed adjustment and thermostatic control. This allows ventilation to be matched more closely to changing environmental conditions instead of operating the fan continuously at maximum output.
The fan features a sturdy steel housing and ABEC 7 ball bearings. It is also compatible with external 0-10V control via RJ9 or RJ11 connection, providing additional flexibility for integration with suitable environmental-control equipment.
Why choose the U-GO 10" EC Extraction Fan?
9-pole digital EC brushless motor
The U-GO uses a 9-pole digital EC brushless motor. EC, or electronically commutated, technology combines a brushless motor with electronic control to provide efficient variable-speed operation.
Variable-speed capability is particularly useful in controlled environments because maximum ventilation is not required continuously. Temperature and air-exchange requirements can change considerably throughout the day.
U-GO states a fan efficiency of 7.85 CFM per watt, with the fan designed to provide strong linear airflow together with useful static-pressure performance.
Static pressure is especially important once a fan is installed in a real ventilation system. Carbon filters, long duct runs, bends and other components all create resistance that the fan must overcome to maintain airflow.
Digital thermostatic controller included
The U-GO 250mm EC Fan is supplied with its own detachable digital controller, allowing fan speed and temperature-responsive ventilation to be managed without purchasing a separate basic speed controller.
Fully variable speed control allows the airflow to be reduced when maximum extraction is unnecessary and increased as ventilation demand rises.
Thermostatic control adds another level of automation by allowing ventilation to respond to environmental temperature.
Operating the fan only as hard as necessary can help reduce unnecessary energy consumption, airflow noise and excessive air exchange while maintaining the required environmental conditions.
1840m³/h high-capacity airflow
With a maximum airflow of 1840 cubic metres per hour, this 10" U-GO is designed for larger ventilation applications requiring substantial air movement.
Maximum airflow is not the same as the airflow that will necessarily be achieved once the fan is installed. Every component added to the system introduces some degree of resistance.
Carbon filters, silencers, duct length, bends, reducers and compressed flexible ducting can all lower the actual airflow delivered by the complete installation.
Keeping ductwork correctly sized, reasonably straight and free from unnecessary restrictions allows the fan to make better use of its available airflow and pressure capability.
250mm / 10" ventilation connection
The fan uses a nominal 250mm / 10" connection for integration with compatible high-airflow ducting, carbon filters and ventilation fittings.
Maintaining the 250mm diameter throughout as much of the system as practical helps minimise unnecessary static pressure and excessive air velocity.
Reducing immediately into substantially smaller ducting can restrict airflow and increase turbulence and noise, limiting the performance available from a high-capacity fan.
0-10V environmental controller compatibility
In addition to the supplied digital controller, the U-GO supports 0-10V external control via RJ9 or RJ11 connection.
A compatible 0-10V controller can regulate the EC fan through a low-voltage control signal rather than attempting to regulate fan speed by altering its mains power supply.
This provides additional options for integrating the U-GO into compatible environmental-control systems where centralised or automated fan-speed control is required.
Always confirm controller compatibility, cable configuration and control-signal requirements before connecting third-party equipment.
Excellent choice for carbon-filtered extraction
High-capacity carbon filters create significant resistance as air is drawn through the activated carbon bed. The extraction fan therefore needs both sufficient airflow and useful static-pressure capability.
The U-GO's combination of 1840m³/h maximum airflow, EC speed control and strong static-pressure performance makes it well suited to larger filtered extraction systems.
Ideally, use a carbon filter with a matching 250mm connection and an airflow rating appropriate to the fan's operating airflow.
Because the U-GO is fully variable, its output can be adjusted to match the carbon filter and environmental requirement rather than simply operating continuously at maximum speed.
Getting the best performance from the U-GO 250mm Fan
A properly designed ventilation system allows the fan to provide the required air exchange at the lowest practical operating speed, helping balance airflow, environmental stability, energy use and noise.
U-GO 10" 250mm EC Fan product details
| Brand | U-GO |
|---|---|
| Product type | Digital EC inline extraction fan |
| Nominal connection | 10" / 250mm |
| Maximum airflow | 1840m³/h |
| Motor technology | 9-pole digital EC brushless motor |
| Stated fan efficiency | 7.85 CFM per watt |
| Speed control | Fully variable |
| Digital controller | Included |
| Temperature control | Thermostatic control via supplied digital controller |
| External control | 0-10V compatible |
| Control connection | RJ9 or RJ11 |
| Housing | Steel |
| Bearings | ABEC 7 ball bearings |
| Typical applications | Extraction, intake, carbon-filtered ventilation & controlled-environment air movement |
U-GO 10" 250mm EC Extraction Fan FAQs
What is the airflow of the U-GO 10" fan?
The 250mm / 10" U-GO EC Fan has a maximum airflow rating of 1840m³/h. Does the U-GO 250mm fan include a controller?
Yes. A detachable digital thermostatic controller is included with the fan. Can I vary the fan speed?
Yes. The supplied digital controller provides fully variable fan-speed adjustment, allowing airflow to be matched to the requirements of the environment. Does the controller automatically respond to temperature?
Yes. The supplied controller provides thermostatic temperature control as well as variable fan-speed adjustment. What does EC mean?
EC stands for electronically commutated. The U-GO uses a 9-pole digital EC brushless motor designed for efficient, variable-speed ventilation. How efficient is the U-GO fan?
U-GO states a fan efficiency of 7.85 CFM per watt for this EC fan design. Can the U-GO be controlled by a 0-10V controller?
Yes. The fan supports 0-10V control via an appropriate RJ9 or RJ11 connection. Compatibility and cable configuration should be confirmed before connecting third-party control equipment. Can I use the U-GO 10" fan with a carbon filter?
Yes. Its airflow and static-pressure capability make it suitable for filtered extraction when paired with an appropriately sized carbon filter. What size carbon filter should I use?
A 250mm / 10" filter provides the most straightforward connection. Its airflow capacity should also be suitable for the actual operating airflow of the fan. Will a carbon filter reduce the 1840m³/h airflow?
Yes. Carbon filters create airflow resistance, so actual installed airflow will normally be lower than the fan's unrestricted maximum airflow rating. What size ducting does the U-GO 250mm fan require?
The fan has a nominal 250mm / 10" connection, so matching 250mm ducting and fittings should be used wherever practical. Can I reduce the fan into smaller ducting?
A reducer can be used where necessary, but reducing duct diameter increases resistance and air velocity and can reduce the airflow available from the system. Why is static pressure important?
Static-pressure capability helps the fan maintain useful airflow when resistance is added by carbon filters, ducting, bends and other ventilation components. What are ABEC 7 ball bearings?
The U-GO motor assembly uses ABEC 7 ball bearings, providing a precision bearing system for smooth fan operation. Can the U-GO 250mm fan be used for intake as well as extraction?
Yes. The fan can be incorporated into appropriately designed intake or extraction ventilation systems.