What does 16 Way + 2 mean?
The board provides 16 sockets for the main timed lighting circuit plus 2 additional auxiliary sockets for compatible supporting equipment such as fans.
VAT will be calculated and added to your order on the payment step of the checkout.
Commercial Products
Commercial Products
Professional Growing Media
Plant Nutrition
Plant Health
Sprayers & Protective Clothing
Pots, Planters & Trays
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Irrigation
Plant Support & Tree Care
Equipment
Tools
Plant Labels
Packaging
Lawn Care
Clearance
Retail Products
Retail Products
Growing Media
Plant Nutrition
Plant Health
Pots, Planters & Tanks
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Plant Support
Equipment
Tools
NEXT Working Day Delivery as Standard
Over 5,000 professional horticultural products in stock
Expert service tailored
for commercial growers
£59.95
Unit price / perEstimated delivery between November 01 and November 03.
The 16 Way + 2 MDF Lighting Timer Board provides centralised switching and power distribution for larger lighting installations, combining 16 timed lighting sockets with 2 auxiliary sockets for compatible fans and supporting equipment.
Rather than controlling numerous lights with individual plug-in timers, the board brings the lighting connections together around a single timer and contactor-controlled switching system.
The 16 timed UK sockets allow compatible lighting equipment to operate from the same automatic schedule, while the 2 auxiliary sockets provide separate connections for compatible ventilation or environmental equipment.
Components are mounted together on a rigid MDF board, creating an organised central control point for larger horticultural lighting installations.
The main section of the board provides 16 timed UK sockets, allowing multiple compatible lighting systems to follow the same automatic operating schedule.
Centralised switching helps maintain a consistent lighting cycle across the installation and avoids having numerous individual timers that each need to be set and checked separately.
This is particularly useful where all lighting within an area needs to switch simultaneously at the beginning and end of each programmed lighting period.
The total electrical load must always be considered when specifying the installation. Socket count alone does not determine the number or wattage of lights that can safely be connected.
Larger lighting installations place much greater demands on switching equipment than a single low-load appliance. Lighting systems can also produce significant starting or inrush currents depending on the technology and control gear being used.
The timer board uses a contactor-controlled arrangement. The timer determines when the lighting should operate, while the contactor system performs the switching of the connected lighting circuit.
This separates the timing function from the high-load switching function and provides a more appropriate arrangement for controlling multiple lighting systems than attempting to place the complete load through an ordinary domestic timer.
Alongside the 16 lighting outlets are 2 auxiliary sockets intended for compatible supporting equipment such as ventilation fans.
Providing separate auxiliary connections makes it easier to integrate equipment that may need to operate independently from the main lighting schedule.
Typical applications can include compatible extraction or intake fans, circulation equipment and other environmental devices, subject to their electrical requirements and the design of the installation.
As the number of lights increases, power distribution can quickly become difficult to manage if it is assembled from numerous individual extension leads, timers and separate connections.
A dedicated timer board provides a much more organised approach by locating the lighting sockets, auxiliary connections, timer and switching components together.
This also makes the installation easier to understand and inspect because the principal lighting connections are located in one central area rather than distributed across multiple independent timers.
A 16-way lighting timer board forms part of a substantial electrical installation. The available electrical supply, connected equipment, circuit protection and cabling must therefore be considered as a complete system.
The MDF board should be securely mounted in a suitable dry location with sufficient access for operation, inspection and maintenance. Keep the complete assembly protected from irrigation water, spray, condensation and excessive moisture.
The electrical supply and installation requirements should be assessed and completed by a suitably qualified electrician.
| Product type | MDF lighting contactor and timer board |
|---|---|
| Timed lighting sockets | 16 |
| Auxiliary sockets | 2 |
| Socket format | UK sockets |
| Lighting control | Integrated timer with contactor-controlled switching |
| Mounting format | MDF board |
| Primary application | Centralised control of larger multi-light installations |
| Typical auxiliary applications | Compatible ventilation fans and supporting environmental equipment |
| Outer case quantity | 4 boards |
The board provides 16 sockets for the main timed lighting circuit plus 2 additional auxiliary sockets for compatible supporting equipment such as fans.
A timer board centralises the lighting connections and switching system. This makes a larger installation easier to organise and allows the connected lighting circuit to follow one common schedule rather than relying on numerous separately programmed timers.
The timer determines when the lighting should switch, while the contactor handles the electrical switching of the connected lighting circuit. This separates the timing function from the higher-load switching function.
They are intended for compatible supporting electrical equipment, with ventilation fans being a typical application. Always check the electrical requirements of the equipment before connection.
The usable lighting capacity depends on the electrical characteristics of the connected equipment and the supply available to the board. The complete connected load must be assessed rather than assuming capacity from the number of sockets alone.
Compatible LED lighting can be used where its drivers, total connected load and starting or inrush characteristics are suitable for the electrical installation and switching equipment.
No. Timer boards can be used with compatible lighting technologies where the electrical characteristics of the connected equipment are suitable. The installation should be specified according to the actual lighting equipment being used.
Lights connected to the same timed circuit follow the board's common timer schedule, allowing the lighting installation to switch together rather than relying on independently programmed timers.
Mount the board securely in a suitable dry location protected from irrigation water, spray, condensation and excessive moisture. It should remain accessible for operation, inspection and maintenance.
The board forms part of a high-capacity multi-way electrical installation. The supply, circuit protection, cabling and connected load should be assessed and installed by a suitably qualified electrician.
This must be determined from the actual electrical characteristics of the lighting equipment, including running load and any starting or inrush current, together with the board and electrical supply specifications. Socket count alone should not be used to calculate electrical capacity.
The outer case quantity is 4 boards.
£59.95
Unit price / perBack in Stock
Sign up to be the first to know when it's back in stock.
The 16 Way + 2 MDF Lighting Timer Board provides centralised switching and power distribution for larger lighting installations, combining 16 timed lighting sockets with 2 auxiliary sockets for compatible fans and supporting equipment.
Rather than controlling numerous lights with individual plug-in timers, the board brings the lighting connections together around a single timer and contactor-controlled switching system.
The 16 timed UK sockets allow compatible lighting equipment to operate from the same automatic schedule, while the 2 auxiliary sockets provide separate connections for compatible ventilation or environmental equipment.
Components are mounted together on a rigid MDF board, creating an organised central control point for larger horticultural lighting installations.
The main section of the board provides 16 timed UK sockets, allowing multiple compatible lighting systems to follow the same automatic operating schedule.
Centralised switching helps maintain a consistent lighting cycle across the installation and avoids having numerous individual timers that each need to be set and checked separately.
This is particularly useful where all lighting within an area needs to switch simultaneously at the beginning and end of each programmed lighting period.
The total electrical load must always be considered when specifying the installation. Socket count alone does not determine the number or wattage of lights that can safely be connected.
Larger lighting installations place much greater demands on switching equipment than a single low-load appliance. Lighting systems can also produce significant starting or inrush currents depending on the technology and control gear being used.
The timer board uses a contactor-controlled arrangement. The timer determines when the lighting should operate, while the contactor system performs the switching of the connected lighting circuit.
This separates the timing function from the high-load switching function and provides a more appropriate arrangement for controlling multiple lighting systems than attempting to place the complete load through an ordinary domestic timer.
Alongside the 16 lighting outlets are 2 auxiliary sockets intended for compatible supporting equipment such as ventilation fans.
Providing separate auxiliary connections makes it easier to integrate equipment that may need to operate independently from the main lighting schedule.
Typical applications can include compatible extraction or intake fans, circulation equipment and other environmental devices, subject to their electrical requirements and the design of the installation.
As the number of lights increases, power distribution can quickly become difficult to manage if it is assembled from numerous individual extension leads, timers and separate connections.
A dedicated timer board provides a much more organised approach by locating the lighting sockets, auxiliary connections, timer and switching components together.
This also makes the installation easier to understand and inspect because the principal lighting connections are located in one central area rather than distributed across multiple independent timers.
A 16-way lighting timer board forms part of a substantial electrical installation. The available electrical supply, connected equipment, circuit protection and cabling must therefore be considered as a complete system.
The MDF board should be securely mounted in a suitable dry location with sufficient access for operation, inspection and maintenance. Keep the complete assembly protected from irrigation water, spray, condensation and excessive moisture.
The electrical supply and installation requirements should be assessed and completed by a suitably qualified electrician.
| Product type | MDF lighting contactor and timer board |
|---|---|
| Timed lighting sockets | 16 |
| Auxiliary sockets | 2 |
| Socket format | UK sockets |
| Lighting control | Integrated timer with contactor-controlled switching |
| Mounting format | MDF board |
| Primary application | Centralised control of larger multi-light installations |
| Typical auxiliary applications | Compatible ventilation fans and supporting environmental equipment |
| Outer case quantity | 4 boards |
The board provides 16 sockets for the main timed lighting circuit plus 2 additional auxiliary sockets for compatible supporting equipment such as fans.
A timer board centralises the lighting connections and switching system. This makes a larger installation easier to organise and allows the connected lighting circuit to follow one common schedule rather than relying on numerous separately programmed timers.
The timer determines when the lighting should switch, while the contactor handles the electrical switching of the connected lighting circuit. This separates the timing function from the higher-load switching function.
They are intended for compatible supporting electrical equipment, with ventilation fans being a typical application. Always check the electrical requirements of the equipment before connection.
The usable lighting capacity depends on the electrical characteristics of the connected equipment and the supply available to the board. The complete connected load must be assessed rather than assuming capacity from the number of sockets alone.
Compatible LED lighting can be used where its drivers, total connected load and starting or inrush characteristics are suitable for the electrical installation and switching equipment.
No. Timer boards can be used with compatible lighting technologies where the electrical characteristics of the connected equipment are suitable. The installation should be specified according to the actual lighting equipment being used.
Lights connected to the same timed circuit follow the board's common timer schedule, allowing the lighting installation to switch together rather than relying on independently programmed timers.
Mount the board securely in a suitable dry location protected from irrigation water, spray, condensation and excessive moisture. It should remain accessible for operation, inspection and maintenance.
The board forms part of a high-capacity multi-way electrical installation. The supply, circuit protection, cabling and connected load should be assessed and installed by a suitably qualified electrician.
This must be determined from the actual electrical characteristics of the lighting equipment, including running load and any starting or inrush current, together with the board and electrical supply specifications. Socket count alone should not be used to calculate electrical capacity.
The outer case quantity is 4 boards.
Pay with
Your transaction is protected with advanced security measures to keep your information confidential
Share
£59.95
Unit price / perStay up-to-date and enjoy discounts and limited time offers, new products and events!
About Us
Creation Horticulture is an independent UK distributor of wholesale garden supplies serving commercial growers, nurseries, landscapers and garden centres. With expert advice, tailored trade support, and thousands of professional products, we help horticultural businesses grow with confidence.
Need help
Got questions?
01889 579 444Need help with your order?
sales@creationhorticulture.co.ukOffice Opening Hours
Monday - Friday 9:00am - 5:00pm

