16 Way MDF Lighting Timer Board - 16 Timed Sockets & 2 Auxiliary Fan Sockets

Please sign in to see pricing

£59.95

Back in Stock

Sign up to be the first to know when it's back in stock.

The 16 Way + 2 MDF Lighting Timer Board provides centralised switching and power distribution for larger lighting installations, combining 16 timed lighting sockets with 2 auxiliary sockets for compatible fans and supporting equipment.

Rather than controlling numerous lights with individual plug-in timers, the board brings the lighting connections together around a single timer and contactor-controlled switching system.

The 16 timed UK sockets allow compatible lighting equipment to operate from the same automatic schedule, while the 2 auxiliary sockets provide separate connections for compatible ventilation or environmental equipment.

Components are mounted together on a rigid MDF board, creating an organised central control point for larger horticultural lighting installations.

Why choose the 16 Way + 2 MDF Lighting Timer Board?

  • 16 timed lighting sockets - centralised automatic switching for a large multi-light installation.
  • 2 auxiliary sockets - additional connections for compatible fans and supporting equipment.
  • Integrated mechanical timer - controls the daily lighting schedule from one central point.
  • Contactor-controlled lighting - suitable architecture for switching multiple lighting loads.
  • Centralised power distribution - keeps numerous lighting connections together in an organised installation.
  • Reduced reliance on individual timers - one central system replaces the need to programme multiple separate plug-in lighting timers.
  • MDF mounting board - sockets, switching components and timer are arranged on a rigid mounting surface.
  • Suitable for larger installations - designed for applications where ordinary single-socket lighting timers are impractical.

16 timed sockets for centralised lighting control

The main section of the board provides 16 timed UK sockets, allowing multiple compatible lighting systems to follow the same automatic operating schedule.

Centralised switching helps maintain a consistent lighting cycle across the installation and avoids having numerous individual timers that each need to be set and checked separately.

This is particularly useful where all lighting within an area needs to switch simultaneously at the beginning and end of each programmed lighting period.

The total electrical load must always be considered when specifying the installation. Socket count alone does not determine the number or wattage of lights that can safely be connected.

Contactor-controlled switching

Larger lighting installations place much greater demands on switching equipment than a single low-load appliance. Lighting systems can also produce significant starting or inrush currents depending on the technology and control gear being used.

The timer board uses a contactor-controlled arrangement. The timer determines when the lighting should operate, while the contactor system performs the switching of the connected lighting circuit.

This separates the timing function from the high-load switching function and provides a more appropriate arrangement for controlling multiple lighting systems than attempting to place the complete load through an ordinary domestic timer.

2 auxiliary sockets for fans & supporting equipment

Alongside the 16 lighting outlets are 2 auxiliary sockets intended for compatible supporting equipment such as ventilation fans.

Providing separate auxiliary connections makes it easier to integrate equipment that may need to operate independently from the main lighting schedule.

Typical applications can include compatible extraction or intake fans, circulation equipment and other environmental devices, subject to their electrical requirements and the design of the installation.

A central control point for larger installations

As the number of lights increases, power distribution can quickly become difficult to manage if it is assembled from numerous individual extension leads, timers and separate connections.

A dedicated timer board provides a much more organised approach by locating the lighting sockets, auxiliary connections, timer and switching components together.

This also makes the installation easier to understand and inspect because the principal lighting connections are located in one central area rather than distributed across multiple independent timers.

Professional fixed installation

A 16-way lighting timer board forms part of a substantial electrical installation. The available electrical supply, connected equipment, circuit protection and cabling must therefore be considered as a complete system.

The MDF board should be securely mounted in a suitable dry location with sufficient access for operation, inspection and maintenance. Keep the complete assembly protected from irrigation water, spray, condensation and excessive moisture.

The electrical supply and installation requirements should be assessed and completed by a suitably qualified electrician.

16 Way + 2 MDF Lighting Timer Board product details

Product type MDF lighting contactor and timer board
Timed lighting sockets 16
Auxiliary sockets 2
Socket format UK sockets
Lighting control Integrated timer with contactor-controlled switching
Mounting format MDF board
Primary application Centralised control of larger multi-light installations
Typical auxiliary applications Compatible ventilation fans and supporting environmental equipment
Outer case quantity 4 boards

16 Way + 2 MDF Lighting Timer Board FAQs

What does 16 Way + 2 mean?

The board provides 16 sockets for the main timed lighting circuit plus 2 additional auxiliary sockets for compatible supporting equipment such as fans.

Why use a lighting timer board instead of individual plug-in timers?

A timer board centralises the lighting connections and switching system. This makes a larger installation easier to organise and allows the connected lighting circuit to follow one common schedule rather than relying on numerous separately programmed timers.

What does the contactor do?

The timer determines when the lighting should switch, while the contactor handles the electrical switching of the connected lighting circuit. This separates the timing function from the higher-load switching function.

What can the two auxiliary sockets be used for?

They are intended for compatible supporting electrical equipment, with ventilation fans being a typical application. Always check the electrical requirements of the equipment before connection.

Can I use all 16 lighting sockets?

The usable lighting capacity depends on the electrical characteristics of the connected equipment and the supply available to the board. The complete connected load must be assessed rather than assuming capacity from the number of sockets alone.

Can this timer board control LED lighting?

Compatible LED lighting can be used where its drivers, total connected load and starting or inrush characteristics are suitable for the electrical installation and switching equipment.

Is a timer board only for HID lighting?

No. Timer boards can be used with compatible lighting technologies where the electrical characteristics of the connected equipment are suitable. The installation should be specified according to the actual lighting equipment being used.

Will all connected lights switch at the same time?

Lights connected to the same timed circuit follow the board's common timer schedule, allowing the lighting installation to switch together rather than relying on independently programmed timers.

Where should the MDF timer board be installed?

Mount the board securely in a suitable dry location protected from irrigation water, spray, condensation and excessive moisture. It should remain accessible for operation, inspection and maintenance.

Does this board need professional electrical installation?

The board forms part of a high-capacity multi-way electrical installation. The supply, circuit protection, cabling and connected load should be assessed and installed by a suitably qualified electrician.

How do I know how many lights the board can safely operate?

This must be determined from the actual electrical characteristics of the lighting equipment, including running load and any starting or inrush current, together with the board and electrical supply specifications. Socket count alone should not be used to calculate electrical capacity.

How many 16 Way + 2 timer boards are in an outer case?

The outer case quantity is 4 boards.

Pay with

  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • Shop Pay
  • Union Pay
  • Visa

Your transaction is protected with advanced security measures to keep your information confidential

£59.95