What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
VAT will be calculated and added to your order on the payment step of the checkout.
Commercial Products
Commercial Products
Professional Growing Media
Plant Nutrition
Plant Health
Sprayers & Protective Clothing
Pots, Planters & Trays
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Irrigation
Plant Support & Tree Care
Equipment
Tools
Plant Labels
Packaging
Lawn Care
Clearance
Retail Products
Retail Products
Growing Media
Plant Nutrition
Plant Health
Pots, Planters & Tanks
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Plant Support
Equipment
Tools
NEXT Working Day Delivery as Standard
Over 5,000 professional horticultural products in stock
Expert service tailored
for commercial growers
£11.50
Unit price / perEstimated delivery between October 03 and October 05.
127mm (5") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Standard flexible ducting moves air effectively, but it can also provide a direct route for sound generated by an extraction fan and turbulent airflow. This can make ventilation equipment considerably more noticeable, particularly in enclosed indoor growing environments.
Mute Silent Ducting surrounds the flexible inner airflow duct with acoustic insulation designed to absorb transmitted sound. It is a practical upgrade from standard uninsulated ducting where quieter ventilation is a priority.
With a 127mm (5") nominal diameter and 5m length, it is ideal for compatible 5-inch fans, carbon filters and ventilation equipment used in grow rooms, propagation areas, indoor horticulture, workshops and other ventilation installations.
Noise within a ventilation system does not come solely from the fan motor. Air moving through the fan, ductwork, filters and fittings can also generate sound, while the duct itself can carry noise from one part of the installation to another.
Acoustic ducting uses an insulating layer around the flexible inner duct to help absorb this transmitted sound. This makes it particularly useful on duct sections immediately before or after an extraction fan and on routes carrying exhaust air away from the growing area.
It can also be used alongside compatible acoustic silencers and suitable fan-speed controllers where a greater level of ventilation noise management is required.
Acoustic ducting reduces transmitted noise rather than making a ventilation system completely silent. Fan motor noise, vibration, airflow velocity and the overall installation all influence the final sound level.
Extraction is essential for controlling temperature, humidity and air exchange in indoor growing environments, but continuously operating fans can become one of the most noticeable sources of background noise.
Replacing standard flexible ducting with insulated acoustic ducting helps reduce sound transmitted along the ventilation route while retaining the flexibility needed to install ductwork around grow room equipment.
The 127mm size is suited to compatible 5-inch ventilation systems and provides a useful balance between airflow capacity and physical size for smaller and medium-sized indoor horticultural installations.
Any ducting system creates some resistance to airflow, and flexible ducting should be installed carefully to avoid adding unnecessary restriction.
Extend the duct sufficiently for the required route rather than leaving large sections heavily compressed. This reduces excessive internal corrugation and provides a smoother route for moving air.
Keep duct runs as short and direct as practical and avoid crushing the duct or creating extremely tight bends. Where a sharp change in direction is required, a compatible rigid metal elbow can provide a cleaner turn.
Carbon filters, silencers, reducers, bends and long duct runs all add resistance to a ventilation system, so the complete installation should be considered when selecting an extraction fan.
Measure the required ventilation route before cutting the ducting. The 5m length can be used as a continuous run or divided into shorter sections depending on the installation.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct over the connection using an appropriately sized duct clamp or clip.
Arrange the surrounding insulation and outer covering neatly around the joint. Suitable HVAC foil tape can also be used where additional sealing is required.
Support longer sections of insulated ducting adequately rather than allowing their full weight to hang from a fan, carbon filter or other ventilation component.
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of the equipment before installation. Nominal metric and imperial ventilation sizes are commonly used together, but exact dimensions can vary slightly between manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 5m length.
Yes, provided the fan uses a compatible nominal 127mm / 5" connection.
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level.
Its insulated construction is specifically designed to reduce transmitted sound compared with basic uninsulated flexible ducting.
Yes. It can be used to connect compatible 127mm / 5" carbon filters, fans and other ventilation equipment.
Yes. Acoustic ducting can be combined with a compatible ventilation silencer where additional noise reduction is required.
Yes. The ducting can be cut to the required length using suitable tools, taking care when cutting the inner duct, reinforcement and insulation.
Yes. It can be incorporated into compatible intake systems as well as extraction installations.
All ductwork introduces some resistance. Keeping the duct reasonably extended and avoiding unnecessary length, compression and tight bends helps minimise additional pressure loss.
Extend it sufficiently for the required run rather than leaving unnecessary sections heavily compressed. This creates a less restrictive internal airflow path.
Yes. Its flexible construction allows it to follow changes in direction, although excessively tight bends that crush or significantly restrict the inner duct should be avoided.
Use an appropriately sized duct clamp or clip to secure the inner duct to compatible fittings. Suitable HVAC foil tape can be added where further sealing is required.
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable.
Correctly sized ducting, smooth airflow routes, vibration isolation, suitable fan-speed control and compatible acoustic silencers can all help create a quieter ventilation system.
£11.50
Unit price / perBack in Stock
Sign up to be the first to know when it's back in stock.
127mm (5") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Standard flexible ducting moves air effectively, but it can also provide a direct route for sound generated by an extraction fan and turbulent airflow. This can make ventilation equipment considerably more noticeable, particularly in enclosed indoor growing environments.
Mute Silent Ducting surrounds the flexible inner airflow duct with acoustic insulation designed to absorb transmitted sound. It is a practical upgrade from standard uninsulated ducting where quieter ventilation is a priority.
With a 127mm (5") nominal diameter and 5m length, it is ideal for compatible 5-inch fans, carbon filters and ventilation equipment used in grow rooms, propagation areas, indoor horticulture, workshops and other ventilation installations.
Noise within a ventilation system does not come solely from the fan motor. Air moving through the fan, ductwork, filters and fittings can also generate sound, while the duct itself can carry noise from one part of the installation to another.
Acoustic ducting uses an insulating layer around the flexible inner duct to help absorb this transmitted sound. This makes it particularly useful on duct sections immediately before or after an extraction fan and on routes carrying exhaust air away from the growing area.
It can also be used alongside compatible acoustic silencers and suitable fan-speed controllers where a greater level of ventilation noise management is required.
Acoustic ducting reduces transmitted noise rather than making a ventilation system completely silent. Fan motor noise, vibration, airflow velocity and the overall installation all influence the final sound level.
Extraction is essential for controlling temperature, humidity and air exchange in indoor growing environments, but continuously operating fans can become one of the most noticeable sources of background noise.
Replacing standard flexible ducting with insulated acoustic ducting helps reduce sound transmitted along the ventilation route while retaining the flexibility needed to install ductwork around grow room equipment.
The 127mm size is suited to compatible 5-inch ventilation systems and provides a useful balance between airflow capacity and physical size for smaller and medium-sized indoor horticultural installations.
Any ducting system creates some resistance to airflow, and flexible ducting should be installed carefully to avoid adding unnecessary restriction.
Extend the duct sufficiently for the required route rather than leaving large sections heavily compressed. This reduces excessive internal corrugation and provides a smoother route for moving air.
Keep duct runs as short and direct as practical and avoid crushing the duct or creating extremely tight bends. Where a sharp change in direction is required, a compatible rigid metal elbow can provide a cleaner turn.
Carbon filters, silencers, reducers, bends and long duct runs all add resistance to a ventilation system, so the complete installation should be considered when selecting an extraction fan.
Measure the required ventilation route before cutting the ducting. The 5m length can be used as a continuous run or divided into shorter sections depending on the installation.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct over the connection using an appropriately sized duct clamp or clip.
Arrange the surrounding insulation and outer covering neatly around the joint. Suitable HVAC foil tape can also be used where additional sealing is required.
Support longer sections of insulated ducting adequately rather than allowing their full weight to hang from a fan, carbon filter or other ventilation component.
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of the equipment before installation. Nominal metric and imperial ventilation sizes are commonly used together, but exact dimensions can vary slightly between manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 5m length.
Yes, provided the fan uses a compatible nominal 127mm / 5" connection.
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level.
Its insulated construction is specifically designed to reduce transmitted sound compared with basic uninsulated flexible ducting.
Yes. It can be used to connect compatible 127mm / 5" carbon filters, fans and other ventilation equipment.
Yes. Acoustic ducting can be combined with a compatible ventilation silencer where additional noise reduction is required.
Yes. The ducting can be cut to the required length using suitable tools, taking care when cutting the inner duct, reinforcement and insulation.
Yes. It can be incorporated into compatible intake systems as well as extraction installations.
All ductwork introduces some resistance. Keeping the duct reasonably extended and avoiding unnecessary length, compression and tight bends helps minimise additional pressure loss.
Extend it sufficiently for the required run rather than leaving unnecessary sections heavily compressed. This creates a less restrictive internal airflow path.
Yes. Its flexible construction allows it to follow changes in direction, although excessively tight bends that crush or significantly restrict the inner duct should be avoided.
Use an appropriately sized duct clamp or clip to secure the inner duct to compatible fittings. Suitable HVAC foil tape can be added where further sealing is required.
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable.
Correctly sized ducting, smooth airflow routes, vibration isolation, suitable fan-speed control and compatible acoustic silencers can all help create a quieter ventilation system.
Pay with
Your transaction is protected with advanced security measures to keep your information confidential
Share
£11.50
Unit price / perStay up-to-date and enjoy discounts and limited time offers, new products and events!
About Us
Creation Horticulture is an independent UK distributor of wholesale garden supplies serving commercial growers, nurseries, landscapers and garden centres. With expert advice, tailored trade support, and thousands of professional products, we help horticultural businesses grow with confidence.
Need help
Got questions?
01889 579 444Need help with your order?
sales@creationhorticulture.co.ukOffice Opening Hours
Monday - Friday 9:00am - 5:00pm