What is acoustic ducting?
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
VAT will be calculated and added to your order on the payment step of the checkout.
Commercial Products
Commercial Products
Professional Growing Media
Plant Nutrition
Plant Health
Sprayers & Protective Clothing
Pots, Planters & Trays
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Irrigation
Plant Support & Tree Care
Equipment
Tools
Plant Labels
Packaging
Lawn Care
Clearance
Retail Products
Retail Products
Growing Media
Plant Nutrition
Plant Health
Pots, Planters & Tanks
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Plant Support
Equipment
Tools
NEXT Working Day Delivery as Standard
Over 5,000 professional horticultural products in stock
Expert service tailored
for commercial growers
£21.75
Unit price / perEstimated delivery between October 03 and October 05.
127mm (5") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation fans are essential for controlling temperature, humidity and air exchange, but the noise they generate can travel through standard ducting. Air movement and turbulence within the duct can also contribute to the overall sound of an extraction system.
Mute Silent Ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical alternative to standard uninsulated flexible ducting where quieter ventilation is required.
With a 127mm (5") nominal diameter and 10m length, this version is particularly useful for longer ventilation runs, larger installations or projects requiring several shorter sections of acoustic ducting.
Standard flexible ducting provides an effective route for moving air, but it can also carry sound generated by the fan and turbulent airflow. That sound can travel along the duct and become audible at other points in the ventilation system.
Acoustic ducting surrounds the flexible inner duct with an insulating layer designed to help absorb transmitted sound. This can reduce the amount of fan and airflow noise carried along the duct run.
It is particularly useful on duct sections immediately before or after an extraction fan, between compatible ventilation components and on longer exhaust routes where transmitted noise may otherwise be noticeable.
Acoustic ducting is a noise-reduction component rather than a complete silencing solution. Fan motor noise, vibration, airflow velocity and the design of the overall ventilation system can all influence the final sound level.
A correctly designed extraction system helps remove excess heat and humidity while maintaining regular air exchange within an indoor growing environment.
Where the extraction system operates continuously or for extended periods, fan and airflow noise can become particularly noticeable. Using acoustic ducting helps reduce sound transmitted through the ductwork while retaining the flexibility needed for practical grow room installations.
The 10m length is especially useful where the extraction point is positioned some distance from the growing area or where several sections of 127mm acoustic ducting are required within the same installation.
Longer duct runs create more airflow resistance than short, direct installations. For this reason, careful routing becomes increasingly important when using a substantial length of flexible ducting.
Use only the length required and extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This helps reduce excessive internal corrugation and provides a less restrictive path for moving air.
Avoid crushed sections and very tight bends wherever possible. Where a significant change in direction is required, an appropriately sized rigid elbow can provide a cleaner airflow route than forcing flexible ducting around an extremely tight corner.
Carbon filters, silencers, reducers, bends and other fittings also add resistance. The complete duct route should therefore be considered when selecting and setting up an extraction fan.
Measure the required route before cutting the ducting. The full 10m length can be used for a longer continuous run or divided into shorter sections depending on the ventilation layout.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct to the connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the connection. Suitable HVAC foil tape can also be used where additional sealing is required.
Longer insulated duct runs should be supported at suitable intervals. Avoid allowing the full weight of the ducting to hang directly from a fan, carbon filter or other ventilation component.
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of adjoining equipment before installation. Nominal metric and imperial ventilation sizes are frequently used together, but exact connection dimensions can vary slightly between manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 10m length.
Yes, provided the fan has a compatible nominal 127mm / 5" connection.
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level.
Its insulated construction is specifically intended to reduce transmitted sound compared with basic uninsulated flexible ventilation ducting.
Yes. It can be used with compatible 127mm / 5" carbon filters, extraction fans and other appropriately sized ventilation components.
Yes. Acoustic ducting and a compatible ventilation silencer can be used together where further reduction of transmitted ventilation noise is required.
Yes. The ducting can be cut to suit the installation using suitable tools, taking care when cutting the flexible inner duct, reinforcement and surrounding insulation.
Yes. It can be incorporated into compatible intake systems as well as extraction installations.
Longer duct runs create more resistance than short runs. The actual effect depends on the fan, bends, filters and other components, so unnecessary excess ducting should be avoided.
It should be extended sufficiently for the required route rather than left heavily compressed. This helps reduce excessive internal corrugation and unnecessary airflow resistance.
Yes. Its flexible construction allows changes in direction, although very tight bends that crush or significantly restrict the inner duct should be avoided.
Secure the inner duct to compatible fittings using an appropriately sized duct clamp or clip. Suitable HVAC foil tape can be added where further sealing is required.
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable.
Use correctly sized ducting, minimise unnecessary bends, isolate fan vibration and consider suitable fan-speed control and compatible acoustic silencers where appropriate.
£21.75
Unit price / perBack in Stock
Sign up to be the first to know when it's back in stock.
127mm (5") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise transmitted through extraction and intake systems.
Ventilation fans are essential for controlling temperature, humidity and air exchange, but the noise they generate can travel through standard ducting. Air movement and turbulence within the duct can also contribute to the overall sound of an extraction system.
Mute Silent Ducting uses an insulated construction around the flexible inner airflow duct to help absorb transmitted sound. It provides a practical alternative to standard uninsulated flexible ducting where quieter ventilation is required.
With a 127mm (5") nominal diameter and 10m length, this version is particularly useful for longer ventilation runs, larger installations or projects requiring several shorter sections of acoustic ducting.
Standard flexible ducting provides an effective route for moving air, but it can also carry sound generated by the fan and turbulent airflow. That sound can travel along the duct and become audible at other points in the ventilation system.
Acoustic ducting surrounds the flexible inner duct with an insulating layer designed to help absorb transmitted sound. This can reduce the amount of fan and airflow noise carried along the duct run.
It is particularly useful on duct sections immediately before or after an extraction fan, between compatible ventilation components and on longer exhaust routes where transmitted noise may otherwise be noticeable.
Acoustic ducting is a noise-reduction component rather than a complete silencing solution. Fan motor noise, vibration, airflow velocity and the design of the overall ventilation system can all influence the final sound level.
A correctly designed extraction system helps remove excess heat and humidity while maintaining regular air exchange within an indoor growing environment.
Where the extraction system operates continuously or for extended periods, fan and airflow noise can become particularly noticeable. Using acoustic ducting helps reduce sound transmitted through the ductwork while retaining the flexibility needed for practical grow room installations.
The 10m length is especially useful where the extraction point is positioned some distance from the growing area or where several sections of 127mm acoustic ducting are required within the same installation.
Longer duct runs create more airflow resistance than short, direct installations. For this reason, careful routing becomes increasingly important when using a substantial length of flexible ducting.
Use only the length required and extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This helps reduce excessive internal corrugation and provides a less restrictive path for moving air.
Avoid crushed sections and very tight bends wherever possible. Where a significant change in direction is required, an appropriately sized rigid elbow can provide a cleaner airflow route than forcing flexible ducting around an extremely tight corner.
Carbon filters, silencers, reducers, bends and other fittings also add resistance. The complete duct route should therefore be considered when selecting and setting up an extraction fan.
Measure the required route before cutting the ducting. The full 10m length can be used for a longer continuous run or divided into shorter sections depending on the ventilation layout.
When connecting to a compatible fan, carbon filter, silencer or rigid fitting, secure the inner duct to the connection using an appropriately sized duct clamp or clip.
Arrange the insulation and outer covering neatly around the connection. Suitable HVAC foil tape can also be used where additional sealing is required.
Longer insulated duct runs should be supported at suitable intervals. Avoid allowing the full weight of the ducting to hang directly from a fan, carbon filter or other ventilation component.
This ducting is intended for nominal 127mm (5") round ventilation installations and can be used with appropriately sized components including:
Always check the actual connection diameter of adjoining equipment before installation. Nominal metric and imperial ventilation sizes are frequently used together, but exact connection dimensions can vary slightly between manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 127mm / 5" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 127mm / 5" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture, propagation areas, workshops & general ventilation installations |
Acoustic ducting is flexible ventilation ducting surrounded by insulation designed to help reduce sound transmitted through the ventilation system.
It has a nominal diameter of 127mm, approximately 5 inches, and is supplied in a 10m length.
Yes, provided the fan has a compatible nominal 127mm / 5" connection.
No. It helps reduce noise transmitted through the ductwork, but fan motor noise, vibration and airflow can still contribute to the overall sound level.
Its insulated construction is specifically intended to reduce transmitted sound compared with basic uninsulated flexible ventilation ducting.
Yes. It can be used with compatible 127mm / 5" carbon filters, extraction fans and other appropriately sized ventilation components.
Yes. Acoustic ducting and a compatible ventilation silencer can be used together where further reduction of transmitted ventilation noise is required.
Yes. The ducting can be cut to suit the installation using suitable tools, taking care when cutting the flexible inner duct, reinforcement and surrounding insulation.
Yes. It can be incorporated into compatible intake systems as well as extraction installations.
Longer duct runs create more resistance than short runs. The actual effect depends on the fan, bends, filters and other components, so unnecessary excess ducting should be avoided.
It should be extended sufficiently for the required route rather than left heavily compressed. This helps reduce excessive internal corrugation and unnecessary airflow resistance.
Yes. Its flexible construction allows changes in direction, although very tight bends that crush or significantly restrict the inner duct should be avoided.
Secure the inner duct to compatible fittings using an appropriately sized duct clamp or clip. Suitable HVAC foil tape can be added where further sealing is required.
Yes. It is particularly useful for indoor horticultural installations using compatible 5-inch extraction equipment where reducing ventilation noise is desirable.
Use correctly sized ducting, minimise unnecessary bends, isolate fan vibration and consider suitable fan-speed control and compatible acoustic silencers where appropriate.
Pay with
Your transaction is protected with advanced security measures to keep your information confidential
Share
£21.75
Unit price / perStay up-to-date and enjoy discounts and limited time offers, new products and events!
About Us
Creation Horticulture is an independent UK distributor of wholesale garden supplies serving commercial growers, nurseries, landscapers and garden centres. With expert advice, tailored trade support, and thousands of professional products, we help horticultural businesses grow with confidence.
Need help
Got questions?
01889 579 444Need help with your order?
sales@creationhorticulture.co.ukOffice Opening Hours
Monday - Friday 9:00am - 5:00pm