What is acoustic ducting?
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
VAT will be calculated and added to your order on the payment step of the checkout.
Commercial Products
Commercial Products
Professional Growing Media
Plant Nutrition
Plant Health
Sprayers & Protective Clothing
Pots, Planters & Trays
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Irrigation
Plant Support & Tree Care
Equipment
Tools
Plant Labels
Packaging
Lawn Care
Clearance
Retail Products
Retail Products
Growing Media
Plant Nutrition
Plant Health
Pots, Planters & Tanks
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Plant Support
Equipment
Tools
NEXT Working Day Delivery as Standard
Over 5,000 professional horticultural products in stock
Expert service tailored
for commercial growers
£21.80
Unit price / perEstimated delivery between October 03 and October 05.
254mm (10") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in powerful extraction and intake systems.
High-capacity ventilation equipment can generate significant noise from the fan itself and from fast-moving air travelling through the ductwork. This insulated ducting provides a practical solution where quieter ventilation is required without sacrificing the flexibility of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound transmitted along the ventilation system. It is particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a 5 metre length with a nominal 254mm / 10" diameter, it is suitable for compatible 10-inch fans, carbon filters and ventilation fittings and can be cut to the required length during installation.
Noise from an extraction system does not only come directly from the fan. Fan noise, vibration and turbulent airflow can travel along ordinary ductwork, allowing sound to become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct run.
It can be particularly effective when used immediately before or after an extraction fan, between a fan and carbon filter, or along duct runs where ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make an extraction system completely silent. Fan type, speed, vibration, airflow velocity and installation quality will all influence the final sound level.
Larger grow rooms and indoor horticultural environments often require powerful ventilation to remove excess heat and humidity and maintain regular air exchange. As fan capacity increases, controlling ventilation noise becomes increasingly important.
The 254mm / 10" diameter makes this ducting suitable for compatible high-volume extraction and intake equipment, while its insulated construction helps reduce the sound transmitted through the ductwork.
It can be used as part of a complete ventilation system incorporating an inline fan, carbon filter, metal duct fittings, reducers and other appropriately sized components.
Good duct installation is important for maintaining the performance of an extraction fan. Every length of ducting, bend and fitting introduces some resistance to airflow.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This provides a smoother internal airflow path and helps reduce avoidable resistance.
Keep the ventilation route as short and direct as practical and avoid crushing the duct or creating unnecessarily tight bends. Gradual changes in direction are preferable to sharp turns.
The supplied 5m length does not need to be used in full. Cutting it to the length actually required can help create a cleaner and more efficient installation.
Before installation, check that the fan, carbon filter and other fittings are compatible with the nominal 254mm / 10" duct size.
Fit the flexible inner duct securely around the ventilation connection and fasten it using a suitably sized duct clamp or fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed connection so that the insulating layer remains as continuous as practical.
Longer sections should be supported appropriately along the route. Avoid allowing the full weight of the ducting to hang directly from an extraction fan, carbon filter or other ventilation component.
254mm acoustic ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of individual components before installation, as dimensions can vary slightly between different ventilation equipment manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 5 metre length.
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Always check the fan connection dimensions before installation.
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of a correctly sized extraction system.
No. It helps reduce noise transmitted through the ductwork but cannot completely eliminate fan motor noise, vibration or airflow noise.
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting.
Yes. The ducting can be incorporated into compatible extraction or fresh-air intake systems.
Yes. It can be cut to suit the required installation, allowing one length to be divided into several sections if necessary.
Only if required. Keeping duct runs reasonably short and direct generally helps reduce resistance and maintain ventilation performance.
Every duct run introduces resistance. Longer routes, tight bends and additional fittings can increase this resistance and reduce the effective airflow delivered by the system.
Yes. Sharp bends increase resistance, so gradual changes in direction are preferable wherever the installation allows.
It should be extended sufficiently for the installation rather than left heavily compressed, helping provide a smoother path for airflow.
It can be used throughout a compatible ventilation route. Sections close to powerful extraction fans can be particularly useful for reducing sound transmitted into the duct system.
Long runs should be adequately supported so the weight of the duct is not carried entirely by the fan, filter or connecting fittings.
Good duct routing, correctly sized ventilation equipment, vibration isolation, suitable fan-speed control and ventilation silencers can all help reduce overall system noise.
£21.80
Unit price / perBack in Stock
Sign up to be the first to know when it's back in stock.
254mm (10") x 5m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in powerful extraction and intake systems.
High-capacity ventilation equipment can generate significant noise from the fan itself and from fast-moving air travelling through the ductwork. This insulated ducting provides a practical solution where quieter ventilation is required without sacrificing the flexibility of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound transmitted along the ventilation system. It is particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a 5 metre length with a nominal 254mm / 10" diameter, it is suitable for compatible 10-inch fans, carbon filters and ventilation fittings and can be cut to the required length during installation.
Noise from an extraction system does not only come directly from the fan. Fan noise, vibration and turbulent airflow can travel along ordinary ductwork, allowing sound to become noticeable elsewhere in the installation.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling through the duct run.
It can be particularly effective when used immediately before or after an extraction fan, between a fan and carbon filter, or along duct runs where ventilation noise needs to be controlled.
Acoustic ducting is intended to reduce transmitted noise rather than make an extraction system completely silent. Fan type, speed, vibration, airflow velocity and installation quality will all influence the final sound level.
Larger grow rooms and indoor horticultural environments often require powerful ventilation to remove excess heat and humidity and maintain regular air exchange. As fan capacity increases, controlling ventilation noise becomes increasingly important.
The 254mm / 10" diameter makes this ducting suitable for compatible high-volume extraction and intake equipment, while its insulated construction helps reduce the sound transmitted through the ductwork.
It can be used as part of a complete ventilation system incorporating an inline fan, carbon filter, metal duct fittings, reducers and other appropriately sized components.
Good duct installation is important for maintaining the performance of an extraction fan. Every length of ducting, bend and fitting introduces some resistance to airflow.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. This provides a smoother internal airflow path and helps reduce avoidable resistance.
Keep the ventilation route as short and direct as practical and avoid crushing the duct or creating unnecessarily tight bends. Gradual changes in direction are preferable to sharp turns.
The supplied 5m length does not need to be used in full. Cutting it to the length actually required can help create a cleaner and more efficient installation.
Before installation, check that the fan, carbon filter and other fittings are compatible with the nominal 254mm / 10" duct size.
Fit the flexible inner duct securely around the ventilation connection and fasten it using a suitably sized duct clamp or fixing. HVAC foil tape can also be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed connection so that the insulating layer remains as continuous as practical.
Longer sections should be supported appropriately along the route. Avoid allowing the full weight of the ducting to hang directly from an extraction fan, carbon filter or other ventilation component.
254mm acoustic ducting can be incorporated into appropriately sized ventilation systems using components such as:
Always check the actual connection diameter of individual components before installation, as dimensions can vary slightly between different ventilation equipment manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 5m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 5 metre length.
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Always check the fan connection dimensions before installation.
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of a correctly sized extraction system.
No. It helps reduce noise transmitted through the ductwork but cannot completely eliminate fan motor noise, vibration or airflow noise.
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting.
Yes. The ducting can be incorporated into compatible extraction or fresh-air intake systems.
Yes. It can be cut to suit the required installation, allowing one length to be divided into several sections if necessary.
Only if required. Keeping duct runs reasonably short and direct generally helps reduce resistance and maintain ventilation performance.
Every duct run introduces resistance. Longer routes, tight bends and additional fittings can increase this resistance and reduce the effective airflow delivered by the system.
Yes. Sharp bends increase resistance, so gradual changes in direction are preferable wherever the installation allows.
It should be extended sufficiently for the installation rather than left heavily compressed, helping provide a smoother path for airflow.
It can be used throughout a compatible ventilation route. Sections close to powerful extraction fans can be particularly useful for reducing sound transmitted into the duct system.
Long runs should be adequately supported so the weight of the duct is not carried entirely by the fan, filter or connecting fittings.
Good duct routing, correctly sized ventilation equipment, vibration isolation, suitable fan-speed control and ventilation silencers can all help reduce overall system noise.
Pay with
Your transaction is protected with advanced security measures to keep your information confidential
Share
£21.80
Unit price / perStay up-to-date and enjoy discounts and limited time offers, new products and events!
About Us
Creation Horticulture is an independent UK distributor of wholesale garden supplies serving commercial growers, nurseries, landscapers and garden centres. With expert advice, tailored trade support, and thousands of professional products, we help horticultural businesses grow with confidence.
Need help
Got questions?
01889 579 444Need help with your order?
sales@creationhorticulture.co.ukOffice Opening Hours
Monday - Friday 9:00am - 5:00pm