What is acoustic ducting?
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
VAT will be calculated and added to your order on the payment step of the checkout.
Commercial Products
Commercial Products
Professional Growing Media
Plant Nutrition
Plant Health
Sprayers & Protective Clothing
Pots, Planters & Trays
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Irrigation
Plant Support & Tree Care
Equipment
Tools
Plant Labels
Packaging
Lawn Care
Clearance
Retail Products
Retail Products
Growing Media
Plant Nutrition
Plant Health
Pots, Planters & Tanks
Propagation
Baskets & Planters
Fabrics & Netting
Environment
Plant Lighting
Plant Support
Equipment
Tools
NEXT Working Day Delivery as Standard
Over 5,000 professional horticultural products in stock
Expert service tailored
for commercial growers
£47.50
Unit price / perEstimated delivery between October 03 and October 05.
254mm (10") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in high-capacity extraction and intake systems.
Powerful ventilation equipment can generate considerable noise from both the fan and the movement of air through the ductwork. This insulated ducting provides a practical way to reduce sound transmission while retaining the flexibility and straightforward installation of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound travelling along the ventilation system. This makes it particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a generous 10 metre length with a nominal 254mm / 10" diameter, the duct can be used as one extended run or cut into shorter sections to suit the installation.
Ventilation noise does not only originate directly from an extraction fan. Fan sound, vibration and turbulent airflow can travel through ordinary ductwork and become audible at other points in the ventilation route.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling along the duct run.
It can be particularly useful immediately before or after an extraction fan, between a fan and carbon filter, or along longer ventilation routes where transmitted sound needs to be controlled.
Acoustic ducting is designed to reduce ventilation noise rather than make an extraction system completely silent. Fan design, fan speed, airflow velocity, vibration, duct routing and installation quality will all influence the final noise level.
Larger grow rooms and controlled horticultural environments can require substantial air movement to manage heat, humidity and general air exchange. As ventilation capacity increases, controlling the associated noise becomes increasingly important.
The 254mm / 10" diameter is suitable for compatible high-volume extraction equipment, while the insulated construction helps reduce sound transmitted through the ducting.
It can be incorporated into complete ventilation systems using compatible inline fans, carbon filters, metal duct fittings, reducers, bends and other appropriately sized components.
Correct installation is important because every length of duct, bend and fitting introduces resistance to airflow. This becomes especially relevant with longer ventilation runs.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. A more fully extended inner duct provides a smoother airflow path and can help reduce avoidable turbulence and resistance.
Keep the route as short and direct as the installation allows. Avoid crushing the duct and minimise tight bends, with gradual changes in direction preferable wherever possible.
Although this product provides 10 metres of ducting, there is no requirement to use the full length. Cutting each section to the amount actually required can help create a cleaner and more efficient ventilation installation.
Check that the fan, carbon filter and other ventilation fittings have compatible nominal 254mm / 10" connections before installation.
Fit the flexible inner duct securely over the ventilation connection and fasten it using an appropriately sized duct clamp or suitable fixing. HVAC foil tape can be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed joint so that the insulating layer remains as continuous as practical.
Long duct runs should be supported at suitable intervals. Avoid allowing the full weight of a long section of ducting to hang directly from the extraction fan, carbon filter or another ventilation component.
Always check the actual connection dimensions of individual components before installation, as nominal sizes and connection details can vary between ventilation equipment manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 10 metre length.
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Check the fan connection dimensions before installation.
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of an appropriately sized extraction system.
No. Acoustic ducting helps reduce noise transmitted through the ductwork, but it cannot completely eliminate fan motor noise, vibration or the sound created by moving air.
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting.
Yes. It can be incorporated into compatible fresh-air intake systems as well as extraction systems.
Yes. The ducting can be cut to suit the installation, making the 10m version useful when several individual duct sections are required.
No. Use only the amount required. Keeping ventilation routes reasonably short and direct generally helps minimise unnecessary resistance.
Longer duct runs introduce additional resistance. Bends, fittings and compressed flexible duct can add further resistance, so ventilation systems should be planned with the total duct route in mind.
Yes. Tight bends can increase airflow resistance, so smooth and gradual changes in direction are preferable where the installation allows.
It should be extended sufficiently for the required run rather than left unnecessarily compressed. This helps provide a smoother internal path for airflow.
It can be used throughout a compatible ventilation route. Sections immediately around powerful extraction fans can be particularly useful where reducing transmitted fan noise is a priority.
Yes. Longer duct runs should be supported appropriately rather than allowing their weight to hang entirely from the fan, filter or connecting fittings.
Acoustic ducting can form part of a quieter installation alongside sensible duct routing, correctly sized fans and filters, vibration isolation, suitable fan-speed control and ventilation silencers.
£47.50
Unit price / perBack in Stock
Sign up to be the first to know when it's back in stock.
254mm (10") x 10m Mute Silent Ducting is an acoustically insulated flexible ventilation duct designed to help reduce fan and airflow noise in high-capacity extraction and intake systems.
Powerful ventilation equipment can generate considerable noise from both the fan and the movement of air through the ductwork. This insulated ducting provides a practical way to reduce sound transmission while retaining the flexibility and straightforward installation of conventional flexible duct.
The flexible inner airflow duct is surrounded by an acoustic insulation layer that helps absorb sound travelling along the ventilation system. This makes it particularly useful in grow rooms and indoor horticultural environments where extraction equipment may operate for extended periods.
Supplied in a generous 10 metre length with a nominal 254mm / 10" diameter, the duct can be used as one extended run or cut into shorter sections to suit the installation.
Ventilation noise does not only originate directly from an extraction fan. Fan sound, vibration and turbulent airflow can travel through ordinary ductwork and become audible at other points in the ventilation route.
Acoustic ducting surrounds the flexible inner air passage with an insulating layer designed to absorb transmitted sound. This helps reduce the amount of fan and airflow noise travelling along the duct run.
It can be particularly useful immediately before or after an extraction fan, between a fan and carbon filter, or along longer ventilation routes where transmitted sound needs to be controlled.
Acoustic ducting is designed to reduce ventilation noise rather than make an extraction system completely silent. Fan design, fan speed, airflow velocity, vibration, duct routing and installation quality will all influence the final noise level.
Larger grow rooms and controlled horticultural environments can require substantial air movement to manage heat, humidity and general air exchange. As ventilation capacity increases, controlling the associated noise becomes increasingly important.
The 254mm / 10" diameter is suitable for compatible high-volume extraction equipment, while the insulated construction helps reduce sound transmitted through the ducting.
It can be incorporated into complete ventilation systems using compatible inline fans, carbon filters, metal duct fittings, reducers, bends and other appropriately sized components.
Correct installation is important because every length of duct, bend and fitting introduces resistance to airflow. This becomes especially relevant with longer ventilation runs.
Extend the duct sufficiently rather than leaving unnecessary sections heavily compressed. A more fully extended inner duct provides a smoother airflow path and can help reduce avoidable turbulence and resistance.
Keep the route as short and direct as the installation allows. Avoid crushing the duct and minimise tight bends, with gradual changes in direction preferable wherever possible.
Although this product provides 10 metres of ducting, there is no requirement to use the full length. Cutting each section to the amount actually required can help create a cleaner and more efficient ventilation installation.
Check that the fan, carbon filter and other ventilation fittings have compatible nominal 254mm / 10" connections before installation.
Fit the flexible inner duct securely over the ventilation connection and fasten it using an appropriately sized duct clamp or suitable fixing. HVAC foil tape can be used where additional sealing is required.
Arrange the acoustic insulation and outer covering neatly around the completed joint so that the insulating layer remains as continuous as practical.
Long duct runs should be supported at suitable intervals. Avoid allowing the full weight of a long section of ducting to hang directly from the extraction fan, carbon filter or another ventilation component.
Always check the actual connection dimensions of individual components before installation, as nominal sizes and connection details can vary between ventilation equipment manufacturers.
| Product type | Acoustic insulated flexible ventilation ducting |
|---|---|
| Nominal diameter | 254mm / 10" |
| Length | 10m |
| Duct type | Flexible |
| Construction | Insulated acoustic ducting |
| Primary purpose | Ventilation with reduced transmission of fan and airflow noise |
| Suitable airflow | Extraction & intake |
| Compatible system size | Nominal 254mm / 10" round ventilation systems |
| Suitable applications | Grow rooms, indoor horticulture & other compatible ventilation installations |
Acoustic ducting is flexible ventilation duct surrounded by insulation designed to help reduce sound transmitted through a ventilation system.
This version has a nominal diameter of 254mm, equivalent to 10 inches, and is supplied in a 10 metre length.
Yes, provided the fan has a compatible nominal 254mm / 10" connection. Check the fan connection dimensions before installation.
Yes. It can be used with a compatible 254mm / 10" carbon filter as part of an appropriately sized extraction system.
No. Acoustic ducting helps reduce noise transmitted through the ductwork, but it cannot completely eliminate fan motor noise, vibration or the sound created by moving air.
Its insulated construction is specifically intended to reduce transmitted ventilation noise compared with basic uninsulated flexible ducting.
Yes. It can be incorporated into compatible fresh-air intake systems as well as extraction systems.
Yes. The ducting can be cut to suit the installation, making the 10m version useful when several individual duct sections are required.
No. Use only the amount required. Keeping ventilation routes reasonably short and direct generally helps minimise unnecessary resistance.
Longer duct runs introduce additional resistance. Bends, fittings and compressed flexible duct can add further resistance, so ventilation systems should be planned with the total duct route in mind.
Yes. Tight bends can increase airflow resistance, so smooth and gradual changes in direction are preferable where the installation allows.
It should be extended sufficiently for the required run rather than left unnecessarily compressed. This helps provide a smoother internal path for airflow.
It can be used throughout a compatible ventilation route. Sections immediately around powerful extraction fans can be particularly useful where reducing transmitted fan noise is a priority.
Yes. Longer duct runs should be supported appropriately rather than allowing their weight to hang entirely from the fan, filter or connecting fittings.
Acoustic ducting can form part of a quieter installation alongside sensible duct routing, correctly sized fans and filters, vibration isolation, suitable fan-speed control and ventilation silencers.
Pay with
Your transaction is protected with advanced security measures to keep your information confidential
Share
£47.50
Unit price / perStay up-to-date and enjoy discounts and limited time offers, new products and events!
About Us
Creation Horticulture is an independent UK distributor of wholesale garden supplies serving commercial growers, nurseries, landscapers and garden centres. With expert advice, tailored trade support, and thousands of professional products, we help horticultural businesses grow with confidence.
Need help
Got questions?
01889 579 444Need help with your order?
sales@creationhorticulture.co.ukOffice Opening Hours
Monday - Friday 9:00am - 5:00pm